var-201907-1075
Vulnerability from variot

An issue was discovered on D-Link DCS-1100 and DCS-1130 devices. The device has a custom telnet daemon as a part of the busybox and retrieves the password from the shadow file using the function getspnam at address 0x00053894. Then performs a crypt operation on the password retrieved from the user at address 0x000538E0 and performs a strcmp at address 0x00053908 to check if the password is correct or incorrect. However, the /etc/shadow file is a part of CRAM-FS filesystem which means that the user cannot change the password and hence a hardcoded hash in /etc/shadow is used to match the credentials provided by the user. This is a salted hash of the string "admin" and hence it acts as a password to the device which cannot be changed as the whole filesystem is read only. D-Link DCS-1100 and DCS-1130 The device contains a vulnerability related to the use of hard-coded credentials.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. The D-LinkDCS-1100 and D-LinkDCS-1130 are both network cameras from D-Link Corporation of Taiwan, China. A trust management vulnerability exists in the D-LinkDCS-1100 and DCS-1130. The vulnerability stems from the fact that the program uses the default password for the Telnet daemon. An attacker could use this vulnerability to log in to the device

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201907-1075",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "dcs-1130",
        "scope": null,
        "trust": 1.4,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-1100",
        "scope": null,
        "trust": 1.4,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-1130",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "dlink",
        "version": null
      },
      {
        "model": "dcs-1100",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "dlink",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-23331"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014561"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-8415"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-1110_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-1130_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014561"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Mandar Satam",
    "sources": [
      {
        "db": "PACKETSTORM",
        "id": "153226"
      }
    ],
    "trust": 0.1
  },
  "cve": "CVE-2017-8415",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2017-8415",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.9,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-23331",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "VHN-116618",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2017-8415",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2017-8415",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2017-8415",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2017-8415",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-23331",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201907-118",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-116618",
            "trust": 0.1,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2017-8415",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-23331"
      },
      {
        "db": "VULHUB",
        "id": "VHN-116618"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-8415"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014561"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201907-118"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-8415"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on D-Link DCS-1100 and DCS-1130 devices. The device has a custom telnet daemon as a part of the busybox and retrieves the password from the shadow file using the function getspnam at address 0x00053894. Then performs a crypt operation on the password retrieved from the user at address 0x000538E0 and performs a strcmp at address 0x00053908 to check if the password is correct or incorrect. However, the /etc/shadow file is a part of CRAM-FS filesystem which means that the user cannot change the password and hence a hardcoded hash in /etc/shadow is used to match the credentials provided by the user. This is a salted hash of the string \"admin\" and hence it acts as a password to the device which cannot be changed as the whole filesystem is read only. D-Link DCS-1100 and DCS-1130 The device contains a vulnerability related to the use of hard-coded credentials.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. The D-LinkDCS-1100 and D-LinkDCS-1130 are both network cameras from D-Link Corporation of Taiwan, China. A trust management vulnerability exists in the D-LinkDCS-1100 and DCS-1130. The vulnerability stems from the fact that the program uses the default password for the Telnet daemon. An attacker could use this vulnerability to log in to the device",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-8415"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014561"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-23331"
      },
      {
        "db": "VULHUB",
        "id": "VHN-116618"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-8415"
      }
    ],
    "trust": 2.34
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2017-8415",
        "trust": 3.3
      },
      {
        "db": "PACKETSTORM",
        "id": "153226",
        "trust": 1.9
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014561",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201907-118",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-23331",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-116618",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-8415",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-23331"
      },
      {
        "db": "VULHUB",
        "id": "VHN-116618"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-8415"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014561"
      },
      {
        "db": "PACKETSTORM",
        "id": "153226"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201907-118"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-8415"
      }
    ]
  },
  "id": "VAR-201907-1075",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-23331"
      },
      {
        "db": "VULHUB",
        "id": "VHN-116618"
      }
    ],
    "trust": 1.30915275
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-23331"
      }
    ]
  },
  "last_update_date": "2024-11-23T21:37:04.689000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.dlink.com/en/consumer"
      },
      {
        "title": "IoT_vulnerabilities",
        "trust": 0.1,
        "url": "https://github.com/ethanhunnt/IoT_vulnerabilities "
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2017-8415"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014561"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-798",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-116618"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014561"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-8415"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.6,
        "url": "https://github.com/ethanhunnt/iot_vulnerabilities/blob/master/dlink_dcs_1130_security.pdf"
      },
      {
        "trust": 2.4,
        "url": "http://packetstormsecurity.com/files/153226/dlink-dcs-1130-command-injection-csrf-stack-overflow.html"
      },
      {
        "trust": 2.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-8415"
      },
      {
        "trust": 1.8,
        "url": "https://seclists.org/bugtraq/2019/jun/8"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-8415"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/798.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://github.com/ethanhunnt/iot_vulnerabilities"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-8408"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-8413"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-8405"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-8406"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-8410"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-8412"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-8409"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-8417"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-8404"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-8416"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-8411"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-8407"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-8414"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-23331"
      },
      {
        "db": "VULHUB",
        "id": "VHN-116618"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-8415"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014561"
      },
      {
        "db": "PACKETSTORM",
        "id": "153226"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201907-118"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-8415"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-23331"
      },
      {
        "db": "VULHUB",
        "id": "VHN-116618"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-8415"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014561"
      },
      {
        "db": "PACKETSTORM",
        "id": "153226"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201907-118"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-8415"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-07-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-23331"
      },
      {
        "date": "2019-07-02T00:00:00",
        "db": "VULHUB",
        "id": "VHN-116618"
      },
      {
        "date": "2019-07-02T00:00:00",
        "db": "VULMON",
        "id": "CVE-2017-8415"
      },
      {
        "date": "2019-07-11T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-014561"
      },
      {
        "date": "2019-06-07T15:06:02",
        "db": "PACKETSTORM",
        "id": "153226"
      },
      {
        "date": "2019-07-02T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201907-118"
      },
      {
        "date": "2019-07-02T21:15:10.493000",
        "db": "NVD",
        "id": "CVE-2017-8415"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-07-19T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-23331"
      },
      {
        "date": "2019-07-10T00:00:00",
        "db": "VULHUB",
        "id": "VHN-116618"
      },
      {
        "date": "2021-04-26T00:00:00",
        "db": "VULMON",
        "id": "CVE-2017-8415"
      },
      {
        "date": "2019-07-11T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-014561"
      },
      {
        "date": "2021-04-27T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201907-118"
      },
      {
        "date": "2024-11-21T03:33:59.780000",
        "db": "NVD",
        "id": "CVE-2017-8415"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201907-118"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "D-Link DCS-1100 and  DCS-1130 Vulnerabilities related to the use of hard-coded credentials on devices",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014561"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "trust management problem",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201907-118"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.