var-201907-1072
Vulnerability from variot
An issue was discovered on D-Link DCS-1100 and DCS-1130 devices. The device has a custom binary called mp4ts under the /var/www/video folder. It seems that this binary dumps the HTTP VERB in the system logs. As a part of doing that it retrieves the HTTP VERB sent by the user and uses a vulnerable sprintf function at address 0x0000C3D4 in the function sub_C210 to copy the value into a string and then into a log file. Since there is no bounds check being performed on the environment variable at address 0x0000C360 this results in a stack overflow and overwrites the PC register allowing an attacker to execute buffer overflow or even a command injection attack. D-Link DCS-1100 and DCS-1130 The device contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Both D-Link DCS-1100 and D-Link DCS-1130 are a network camera produced by D-Link Company in Taiwan, China. An attacker could exploit this vulnerability to execute arbitrary commands on the device
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201907-1072", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "dcs-1130", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": null }, { "model": "dcs-1100", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": null }, { "model": "dcs-1100", "scope": null, "trust": 0.8, "vendor": "d link", "version": null }, { "model": "dcs-1130", "scope": null, "trust": 0.8, "vendor": "d link", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2017-014563" }, { "db": "NVD", "id": "CVE-2017-8412" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:d-link:dcs-1110_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:d-link:dcs-1130_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2017-014563" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Mandar Satam", "sources": [ { "db": "PACKETSTORM", "id": "153226" } ], "trust": 0.1 }, "cve": "CVE-2017-8412", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CVE-2017-8412", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.9, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "VHN-116615", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:A/AC:L/AU:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2017-8412", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2017-8412", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2017-8412", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2017-8412", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-201907-120", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-116615", "trust": 0.1, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2017-8412", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULHUB", "id": "VHN-116615" }, { "db": "VULMON", "id": "CVE-2017-8412" }, { "db": "JVNDB", "id": "JVNDB-2017-014563" }, { "db": "CNNVD", "id": "CNNVD-201907-120" }, { "db": "NVD", "id": "CVE-2017-8412" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An issue was discovered on D-Link DCS-1100 and DCS-1130 devices. The device has a custom binary called mp4ts under the /var/www/video folder. It seems that this binary dumps the HTTP VERB in the system logs. As a part of doing that it retrieves the HTTP VERB sent by the user and uses a vulnerable sprintf function at address 0x0000C3D4 in the function sub_C210 to copy the value into a string and then into a log file. Since there is no bounds check being performed on the environment variable at address 0x0000C360 this results in a stack overflow and overwrites the PC register allowing an attacker to execute buffer overflow or even a command injection attack. D-Link DCS-1100 and DCS-1130 The device contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Both D-Link DCS-1100 and D-Link DCS-1130 are a network camera produced by D-Link Company in Taiwan, China. An attacker could exploit this vulnerability to execute arbitrary commands on the device", "sources": [ { "db": "NVD", "id": "CVE-2017-8412" }, { "db": "JVNDB", "id": "JVNDB-2017-014563" }, { "db": "VULHUB", "id": "VHN-116615" }, { "db": "VULMON", "id": "CVE-2017-8412" } ], "trust": 1.8 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2017-8412", "trust": 2.7 }, { "db": "PACKETSTORM", "id": "153226", "trust": 1.9 }, { "db": "JVNDB", "id": "JVNDB-2017-014563", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201907-120", "trust": 0.7 }, { "db": "VULHUB", "id": "VHN-116615", "trust": 0.1 }, { "db": "VULMON", "id": "CVE-2017-8412", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-116615" }, { "db": "VULMON", "id": "CVE-2017-8412" }, { "db": "JVNDB", "id": "JVNDB-2017-014563" }, { "db": "PACKETSTORM", "id": "153226" }, { "db": "CNNVD", "id": "CNNVD-201907-120" }, { "db": "NVD", "id": "CVE-2017-8412" } ] }, "id": "VAR-201907-1072", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-116615" } ], "trust": 0.70915275 }, "last_update_date": "2024-11-23T21:37:04.916000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top Page", "trust": 0.8, "url": "https://www.dlink.com/en/consumer" }, { "title": "IoT_vulnerabilities", "trust": 0.1, "url": "https://github.com/ethanhunnt/IoT_vulnerabilities " } ], "sources": [ { "db": "VULMON", "id": "CVE-2017-8412" }, { "db": "JVNDB", "id": "JVNDB-2017-014563" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-119", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-116615" }, { "db": "JVNDB", "id": "JVNDB-2017-014563" }, { "db": "NVD", "id": "CVE-2017-8412" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.6, "url": "https://github.com/ethanhunnt/iot_vulnerabilities/blob/master/dlink_dcs_1130_security.pdf" }, { "trust": 2.4, "url": "http://packetstormsecurity.com/files/153226/dlink-dcs-1130-command-injection-csrf-stack-overflow.html" }, { "trust": 1.8, "url": "https://seclists.org/bugtraq/2019/jun/8" }, { "trust": 1.5, "url": "https://nvd.nist.gov/vuln/detail/cve-2017-8412" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-8412" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/119.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://github.com/ethanhunnt/iot_vulnerabilities" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2017-8408" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2017-8413" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2017-8405" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2017-8406" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2017-8410" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2017-8409" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2017-8415" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2017-8417" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2017-8404" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2017-8416" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2017-8411" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2017-8407" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2017-8414" } ], "sources": [ { "db": "VULHUB", "id": "VHN-116615" }, { "db": "VULMON", "id": "CVE-2017-8412" }, { "db": "JVNDB", "id": "JVNDB-2017-014563" }, { "db": "PACKETSTORM", "id": "153226" }, { "db": "CNNVD", "id": "CNNVD-201907-120" }, { "db": "NVD", "id": "CVE-2017-8412" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULHUB", "id": "VHN-116615" }, { "db": "VULMON", "id": "CVE-2017-8412" }, { "db": "JVNDB", "id": "JVNDB-2017-014563" }, { "db": "PACKETSTORM", "id": "153226" }, { "db": "CNNVD", "id": "CNNVD-201907-120" }, { "db": "NVD", "id": "CVE-2017-8412" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-07-02T00:00:00", "db": "VULHUB", "id": "VHN-116615" }, { "date": "2019-07-02T00:00:00", "db": "VULMON", "id": "CVE-2017-8412" }, { "date": "2019-07-11T00:00:00", "db": "JVNDB", "id": "JVNDB-2017-014563" }, { "date": "2019-06-07T15:06:02", "db": "PACKETSTORM", "id": "153226" }, { "date": "2019-07-02T00:00:00", "db": "CNNVD", "id": "CNNVD-201907-120" }, { "date": "2019-07-02T21:15:10.103000", "db": "NVD", "id": "CVE-2017-8412" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-07-10T00:00:00", "db": "VULHUB", "id": "VHN-116615" }, { "date": "2021-04-26T00:00:00", "db": "VULMON", "id": "CVE-2017-8412" }, { "date": "2019-07-11T00:00:00", "db": "JVNDB", "id": "JVNDB-2017-014563" }, { "date": "2021-04-27T00:00:00", "db": "CNNVD", "id": "CNNVD-201907-120" }, { "date": "2024-11-21T03:33:59.320000", "db": "NVD", "id": "CVE-2017-8412" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-201907-120" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "D-Link DCS-1100 and DCS-1130 Device buffer error vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2017-014563" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-201907-120" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.