A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2. plural Schneider Electric The product is vulnerable to a lack of authentication for critical functions.Tampering with information and disrupting service operations (DoS) There is a possibility of being put into a state. Schneider Electric Modicon M100 and others are products of Schneider Electric, France. The Schneider Electric Modicon M100 is a programmable logic controller. The Schneider Electric Modicon LMC078 is a motion controller. The Schneider Electric ATV IMC drive controller is a drive controller. An access control error vulnerability exists in several Schneider Electric products. The following products and versions are affected: Schneider Electric Modicon M100 (all versions); Modicon M200 (all versions); Modicon M221 (all versions); ATV IMC drive controller (all versions); Modicon M241 (all versions); Modicon M258 (all versions); Modicon LMC058 (all versions); Modicon LMC078 (all versions); PacDrive Eco (all versions); PacDrive Pro (all versions); PacDrive Pro2 (all versions)

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201905-0036",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "modicon m100",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "schneider electric",
        "version": "*"
      },
      {
        "model": "pacdrive eco",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "schneider electric",
        "version": "*"
      },
      {
        "model": "modicon m258",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "schneider electric",
        "version": "*"
      },
      {
        "model": "modicon lmc058",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "schneider electric",
        "version": "*"
      },
      {
        "model": "modicon m251",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "schneider electric",
        "version": "*"
      },
      {
        "model": "modicon m221",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "schneider electric",
        "version": "*"
      },
      {
        "model": "pacdrive pro2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "schneider electric",
        "version": "*"
      },
      {
        "model": "modicon m241",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "schneider electric",
        "version": "*"
      },
      {
        "model": "modicon lmc078",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "schneider electric",
        "version": "*"
      },
      {
        "model": "modicon m200",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "schneider electric",
        "version": "*"
      },
      {
        "model": "pacdrive pro",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "schneider electric",
        "version": "*"
      },
      {
        "model": "atv imc drive controller",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "schneider electric",
        "version": "*"
      },
      {
        "model": "atv imc drive controller",
        "scope": null,
        "trust": 0.8,
        "vendor": "schneider electric",
        "version": null
      },
      {
        "model": "modicon lmc058",
        "scope": null,
        "trust": 0.8,
        "vendor": "schneider electric",
        "version": null
      },
      {
        "model": "modicon lmc078",
        "scope": null,
        "trust": 0.8,
        "vendor": "schneider electric",
        "version": null
      },
      {
        "model": "modicon m100",
        "scope": null,
        "trust": 0.8,
        "vendor": "schneider electric",
        "version": null
      },
      {
        "model": "modicon m200",
        "scope": null,
        "trust": 0.8,
        "vendor": "schneider electric",
        "version": null
      },
      {
        "model": "modicon m221",
        "scope": null,
        "trust": 0.8,
        "vendor": "schneider electric",
        "version": null
      },
      {
        "model": "modicon m241",
        "scope": null,
        "trust": 0.8,
        "vendor": "schneider electric",
        "version": null
      },
      {
        "model": "modicon m251",
        "scope": null,
        "trust": 0.8,
        "vendor": "schneider electric",
        "version": null
      },
      {
        "model": "modicon m258",
        "scope": null,
        "trust": 0.8,
        "vendor": "schneider electric",
        "version": null
      },
      {
        "model": "pacdrive eco",
        "scope": null,
        "trust": 0.8,
        "vendor": "schneider electric",
        "version": null
      },
      {
        "model": "electric modicon m258",
        "scope": null,
        "trust": 0.6,
        "vendor": "schneider",
        "version": null
      },
      {
        "model": "electric modicon lmc058",
        "scope": null,
        "trust": 0.6,
        "vendor": "schneider",
        "version": null
      },
      {
        "model": "electric modicon lmc078",
        "scope": null,
        "trust": 0.6,
        "vendor": "schneider",
        "version": null
      },
      {
        "model": "electric pacdrive eco",
        "scope": null,
        "trust": 0.6,
        "vendor": "schneider",
        "version": null
      },
      {
        "model": "electric pacdrive pro",
        "scope": null,
        "trust": 0.6,
        "vendor": "schneider",
        "version": null
      },
      {
        "model": "electric pacdrive pro2",
        "scope": null,
        "trust": 0.6,
        "vendor": "schneider",
        "version": null
      },
      {
        "model": "electric modicon m200",
        "scope": null,
        "trust": 0.6,
        "vendor": "schneider",
        "version": null
      },
      {
        "model": "electric modicon m221",
        "scope": null,
        "trust": 0.6,
        "vendor": "schneider",
        "version": null
      },
      {
        "model": "electric atv imc drive controller",
        "scope": null,
        "trust": 0.6,
        "vendor": "schneider",
        "version": null
      },
      {
        "model": "electric modicon m241",
        "scope": null,
        "trust": 0.6,
        "vendor": "schneider",
        "version": null
      },
      {
        "model": "electric modicon m251",
        "scope": null,
        "trust": 0.6,
        "vendor": "schneider",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "modicon m100",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "pacdrive eco",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "pacdrive pro",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "pacdrive pro2",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "modicon m200",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "modicon m221",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "atv imc drive controller",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "modicon m241",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "modicon m251",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "modicon m258",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "modicon lmc058",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "modicon lmc078",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "275e0d38-40d0-4c09-b739-ba01427ab4f3"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-15887"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004816"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6820"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:schneider_electric:atv_imc_drive_controller_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:schneider_electric:modicon_lmc058_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:schneider_electric:modicon_lmc078_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:schneider_electric:modicon_m100_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:schneider_electric:modicon_m200_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:schneider_electric:modicon_m221_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:schneider_electric:modicon_m241_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:schneider_electric:modicon_m251_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:schneider_electric:modicon_m258_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:schneider_electric:pacdrive_eco_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004816"
      }
    ]
  },
  "cve": "CVE-2019-6820",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.4,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2019-6820",
            "impactScore": 4.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.9,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.4,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-15887",
            "impactScore": 4.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.4,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "275e0d38-40d0-4c09-b739-ba01427ab4f3",
            "impactScore": 4.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:P",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.4,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-158255",
            "impactScore": 4.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2019-6820",
            "impactScore": 4.2,
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 8.2,
            "baseSeverity": "High",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2019-6820",
            "impactScore": null,
            "integrityImpact": "Low",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2019-6820",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2019-6820",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-15887",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201905-932",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "IVD",
            "id": "275e0d38-40d0-4c09-b739-ba01427ab4f3",
            "trust": 0.2,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-158255",
            "trust": 0.1,
            "value": "MEDIUM"
          },
          {
            "author": "VULMON",
            "id": "CVE-2019-6820",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "275e0d38-40d0-4c09-b739-ba01427ab4f3"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-15887"
      },
      {
        "db": "VULHUB",
        "id": "VHN-158255"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-6820"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004816"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-932"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6820"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2. plural Schneider Electric The product is vulnerable to a lack of authentication for critical functions.Tampering with information and disrupting service operations (DoS) There is a possibility of being put into a state. Schneider Electric Modicon M100 and others are products of Schneider Electric, France. The Schneider Electric Modicon M100 is a programmable logic controller. The Schneider Electric Modicon LMC078 is a motion controller. The Schneider Electric ATV IMC drive controller is a drive controller. An access control error vulnerability exists in several Schneider Electric products. The following products and versions are affected: Schneider Electric Modicon M100 (all versions); Modicon M200 (all versions); Modicon M221 (all versions); ATV IMC drive controller (all versions); Modicon M241 (all versions); Modicon M258 (all versions); Modicon LMC058 (all versions); Modicon LMC078 (all versions); PacDrive Eco (all versions); PacDrive Pro (all versions); PacDrive Pro2 (all versions)",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-6820"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004816"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-15887"
      },
      {
        "db": "IVD",
        "id": "275e0d38-40d0-4c09-b739-ba01427ab4f3"
      },
      {
        "db": "VULHUB",
        "id": "VHN-158255"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-6820"
      }
    ],
    "trust": 2.52
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2019-6820",
        "trust": 3.4
      },
      {
        "db": "SCHNEIDER",
        "id": "SEVD-2019-134-02",
        "trust": 1.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-932",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-15887",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004816",
        "trust": 0.8
      },
      {
        "db": "IVD",
        "id": "275E0D38-40D0-4C09-B739-BA01427AB4F3",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-158255",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-6820",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "275e0d38-40d0-4c09-b739-ba01427ab4f3"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-15887"
      },
      {
        "db": "VULHUB",
        "id": "VHN-158255"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-6820"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004816"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-932"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6820"
      }
    ]
  },
  "id": "VAR-201905-0036",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "275e0d38-40d0-4c09-b739-ba01427ab4f3"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-15887"
      },
      {
        "db": "VULHUB",
        "id": "VHN-158255"
      }
    ],
    "trust": 1.8366883125000002
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "275e0d38-40d0-4c09-b739-ba01427ab4f3"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-15887"
      }
    ]
  },
  "last_update_date": "2024-11-23T23:11:53.057000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SEVD-2019-134-02",
        "trust": 0.8,
        "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-02/"
      },
      {
        "title": "CVE-2019-6820",
        "trust": 0.1,
        "url": "https://github.com/AlAIAL90/CVE-2019-6820 "
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2019-6820"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004816"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-306",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158255"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004816"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6820"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://www.schneider-electric.com/en/download/document/sevd-2019-134-02/"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-6820"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-6820"
      },
      {
        "trust": 0.6,
        "url": "https://web.nvd.nist.gov//vuln/detail/cve-2019-6820"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/306.html"
      },
      {
        "trust": 0.1,
        "url": "https://github.com/alaial90/cve-2019-6820"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-15887"
      },
      {
        "db": "VULHUB",
        "id": "VHN-158255"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-6820"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004816"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-932"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6820"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "275e0d38-40d0-4c09-b739-ba01427ab4f3"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-15887"
      },
      {
        "db": "VULHUB",
        "id": "VHN-158255"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-6820"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004816"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-932"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6820"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-05-30T00:00:00",
        "db": "IVD",
        "id": "275e0d38-40d0-4c09-b739-ba01427ab4f3"
      },
      {
        "date": "2019-05-30T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-15887"
      },
      {
        "date": "2019-05-22T00:00:00",
        "db": "VULHUB",
        "id": "VHN-158255"
      },
      {
        "date": "2019-05-22T00:00:00",
        "db": "VULMON",
        "id": "CVE-2019-6820"
      },
      {
        "date": "2019-06-10T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-004816"
      },
      {
        "date": "2019-05-22T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201905-932"
      },
      {
        "date": "2019-05-22T20:29:02.137000",
        "db": "NVD",
        "id": "CVE-2019-6820"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-05-30T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-15887"
      },
      {
        "date": "2019-10-09T00:00:00",
        "db": "VULHUB",
        "id": "VHN-158255"
      },
      {
        "date": "2021-08-26T00:00:00",
        "db": "VULMON",
        "id": "CVE-2019-6820"
      },
      {
        "date": "2019-06-10T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-004816"
      },
      {
        "date": "2022-03-10T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201905-932"
      },
      {
        "date": "2024-11-21T04:47:13.107000",
        "db": "NVD",
        "id": "CVE-2019-6820"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-932"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Schneider Electric Vulnerability related to lack of certification for critical functions in the product",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004816"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Access control error",
    "sources": [
      {
        "db": "IVD",
        "id": "275e0d38-40d0-4c09-b739-ba01427ab4f3"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-932"
      }
    ],
    "trust": 0.8
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.