var-201812-0065
Vulnerability from variot

D-Link DCS series Wi-Fi cameras expose sensitive information regarding the device configuration. The affected devices include many of DCS series, such as: DCS-936L, DCS-942L, DCS-8000LH, DCS-942LB1, DCS-5222L, DCS-825L, DCS-2630L, DCS-820L, DCS-855L, DCS-2121, DCS-5222LB1, DCS-5020L, and many more. There are many affected firmware versions starting from 1.00 and above. The configuration file can be accessed remotely through: /common/info.cgi, with no authentication. The configuration file include the following fields: model, product, brand, version, build, hw_version, nipca version, device name, location, MAC address, IP address, gateway IP address, wireless status, input/output settings, speaker, and sensor settings. / Output settings, speaker and sensor settings information, etc. D-Link DCS-936L, etc. The following products are affected: D-Link DCS-936L; DCS-942L; DCS-8000LH; DCS-942LB1; 5222LB1; DCS-5020L, etc

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201812-0065",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "dcs-936l",
        "scope": null,
        "trust": 1.4,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-942l",
        "scope": null,
        "trust": 1.4,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-8000lh",
        "scope": null,
        "trust": 1.4,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-942lb1",
        "scope": null,
        "trust": 1.4,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-5222l",
        "scope": null,
        "trust": 1.4,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-825l",
        "scope": null,
        "trust": 1.4,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-2630l",
        "scope": null,
        "trust": 1.4,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-820l",
        "scope": null,
        "trust": 1.4,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-855l",
        "scope": null,
        "trust": 1.4,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-2121",
        "scope": null,
        "trust": 1.4,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-930l",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.00"
      },
      {
        "model": "dcs-5030l",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.00"
      },
      {
        "model": "dcs-933l",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.00"
      },
      {
        "model": "dcs-5222l",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "d link",
        "version": "1.00"
      },
      {
        "model": "dcs-936l",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "d link",
        "version": "1.00"
      },
      {
        "model": "dcs-825l",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "d link",
        "version": "1.00"
      },
      {
        "model": "dcs-2630l",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "d link",
        "version": "1.00"
      },
      {
        "model": "dcs-942lb1",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "d link",
        "version": "1.00"
      },
      {
        "model": "dcs-5222lb1",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "d link",
        "version": "1.00"
      },
      {
        "model": "dcs-8100lh",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "d link",
        "version": "1.00"
      },
      {
        "model": "dcs-932l",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.00"
      },
      {
        "model": "dcs-2102",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "d link",
        "version": "1.00"
      },
      {
        "model": "dcs-942l",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.00"
      },
      {
        "model": "dcs-5020l",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.00"
      },
      {
        "model": "dcs-820l",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "d link",
        "version": "1.00"
      },
      {
        "model": "dcs-2121",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "d link",
        "version": "1.00"
      },
      {
        "model": "dcs-8000lh",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "d link",
        "version": "1.00"
      },
      {
        "model": "dcs-855l",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "d link",
        "version": "1.00"
      },
      {
        "model": "dcs-5222lb1",
        "scope": null,
        "trust": 0.6,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-5020l",
        "scope": null,
        "trust": 0.6,
        "vendor": "d link",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "dcs 942lb1",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 936l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 2121",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 5222lb1",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 5020l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 930l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 8100lh",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 932l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 2102",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 933l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 5030l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 942l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 8000lh",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 5222l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 825l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 2630l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 820l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 855l",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d831f62-463f-11e9-8196-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-26797"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014473"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18441"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-2121_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-2630l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-5222l__firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-8000lh_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-820l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-825l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-855l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-936l",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-942l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-942lb1_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014473"
      }
    ]
  },
  "cve": "CVE-2018-18441",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-18441",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2018-26797",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "7d831f62-463f-11e9-8196-000c29342cb1",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-129001",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-18441",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-18441",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-18441",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2018-26797",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201812-968",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "IVD",
            "id": "7d831f62-463f-11e9-8196-000c29342cb1",
            "trust": 0.2,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-129001",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d831f62-463f-11e9-8196-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-26797"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129001"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014473"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-968"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18441"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "D-Link DCS series Wi-Fi cameras expose sensitive information regarding the device configuration. The affected devices include many of DCS series, such as: DCS-936L, DCS-942L, DCS-8000LH, DCS-942LB1, DCS-5222L, DCS-825L, DCS-2630L, DCS-820L, DCS-855L, DCS-2121, DCS-5222LB1, DCS-5020L, and many more. There are many affected firmware versions starting from 1.00 and above. The configuration file can be accessed remotely through: \u003cCamera-IP\u003e/common/info.cgi, with no authentication. The configuration file include the following fields: model, product, brand, version, build, hw_version, nipca version, device name, location, MAC address, IP address, gateway IP address, wireless status, input/output settings, speaker, and sensor settings. / Output settings, speaker and sensor settings information, etc. D-Link DCS-936L, etc. The following products are affected: D-Link DCS-936L; DCS-942L; DCS-8000LH; DCS-942LB1; 5222LB1; DCS-5020L, etc",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-18441"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014473"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-26797"
      },
      {
        "db": "IVD",
        "id": "7d831f62-463f-11e9-8196-000c29342cb1"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129001"
      }
    ],
    "trust": 2.43
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-18441",
        "trust": 3.3
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-968",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-26797",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014473",
        "trust": 0.8
      },
      {
        "db": "IVD",
        "id": "7D831F62-463F-11E9-8196-000C29342CB1",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-129001",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d831f62-463f-11e9-8196-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-26797"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129001"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014473"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-968"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18441"
      }
    ]
  },
  "id": "VAR-201812-0065",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "7d831f62-463f-11e9-8196-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-26797"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129001"
      }
    ],
    "trust": 1.5519531171428573
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS",
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      },
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.2
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d831f62-463f-11e9-8196-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-26797"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:41:38.776000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.dlink.com/en/consumer"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014473"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-200",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-129001"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014473"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18441"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://dojo.bullguard.com/dojo-by-bullguard/blog/i-got-my-eyeon-you-security-vulnerabilities-in-baby-monitor/"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18441"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18441"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-26797"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129001"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014473"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-968"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18441"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "7d831f62-463f-11e9-8196-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-26797"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129001"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014473"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-968"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18441"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-12-28T00:00:00",
        "db": "IVD",
        "id": "7d831f62-463f-11e9-8196-000c29342cb1"
      },
      {
        "date": "2018-12-27T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-26797"
      },
      {
        "date": "2018-12-20T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129001"
      },
      {
        "date": "2019-03-25T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-014473"
      },
      {
        "date": "2018-12-21T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201812-968"
      },
      {
        "date": "2018-12-20T23:29:00.707000",
        "db": "NVD",
        "id": "CVE-2018-18441"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-01-02T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-26797"
      },
      {
        "date": "2019-02-13T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129001"
      },
      {
        "date": "2019-03-25T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-014473"
      },
      {
        "date": "2023-04-27T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201812-968"
      },
      {
        "date": "2024-11-21T03:55:56.640000",
        "db": "NVD",
        "id": "CVE-2018-18441"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-968"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  D-Link DCS series Product  Wi-Fi Information disclosure vulnerability in cameras",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014473"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "information disclosure",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-968"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.