SEVD-2025-014-07

Vulnerability from csaf_se - Published: 2025-01-14 07:00 - Updated: 2025-11-11 08:00
Summary
FlexNet Publisher Vulnerability

Notes

General Security Recommendations
We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the “Program” mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.
For More Information
This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. Customers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric’s Customer Care Center if you need assistance removing a patch. For further information related to cybersecurity in Schneider Electric’s products, visit the company’s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp
LEGAL DISCLAIMER
THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION
About Schneider Electric
Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all.
Overview
Schneider Electric is aware of a vulnerability disclosed on Revenera FlexNet Publisher component. Many vendors, including Schneider Electric, embed Revenera FlexNet Publisher in their offers. Failure to apply the remediation/mitigations provided below may risk a local privilege escalation, which could lead to the execution of a malicious DLL with elevated privilege. February 2025 Update: A remediation is available for the EcoStruxure™ Process Expert offer. The EcoStruxure™ Process Expert for AVEVA System Platform offer is added to the “Affected Product and Versions” section.

{
  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Public",
      "tlp": {
        "label": "WHITE"
      }
    },
    "lang": "en-US",
    "notes": [
      {
        "category": "general",
        "text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
        "title": "General Security Recommendations"
      },
      {
        "category": "general",
        "text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\n\n Customers should use appropriate patching methodologies when applying these patches to their systems. We\r\nstrongly recommend the use of back-ups and evaluating the impact of these patches in a Test and\r\nDevelopment environment or on an offline infrastructure. Contact Schneider Electric\u2019s Customer Care Center if\r\nyou need assistance removing a patch.\n\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
        "title": "For More Information"
      },
      {
        "category": "legal_disclaimer",
        "text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND.  SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
        "title": "LEGAL DISCLAIMER"
      },
      {
        "category": "general",
        "text": "Schneider\u0027s purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and\r\nsustainability for all. We call this Life Is On.\n\nOur mission is to be the trusted partner in Sustainability and Efficiency.\n\nWe are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart\r\nindustries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep\r\ndomain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation,\r\nsoftware and services, delivering digital twins to enable profitable growth for our customers.\n\nWe are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries\r\nto ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our\r\nmeaningful purpose of a sustainable future for all.",
        "title": "About Schneider Electric"
      },
      {
        "category": "summary",
        "text": "Schneider Electric is aware of a vulnerability disclosed on Revenera FlexNet Publisher component. \r\nMany vendors, including Schneider Electric, embed Revenera FlexNet Publisher in their offers.\r\nFailure to apply the remediation/mitigations provided below may risk a local privilege escalation, which could \r\nlead to the execution of a malicious DLL with elevated privilege. February 2025 Update: A remediation is available for the EcoStruxure\u2122 Process Expert offer. The\r\nEcoStruxure\u2122 Process Expert for AVEVA System Platform offer is added to the \u201cAffected Product and\r\nVersions\u201d section.",
        "title": "Overview"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "cpcert@se.com",
      "name": "Schneider Electric CPCERT",
      "namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
    },
    "references": [
      {
        "category": "self",
        "summary": "FlexNet Publisher Vulnerability - SEVD-2025-014-07 PDF Version",
        "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-07\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-07.pdf"
      },
      {
        "category": "self",
        "summary": "FlexNet Publisher Vulnerability - SEVD-2025-014-07 CSAF Version",
        "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-07\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2025-014-07.json"
      },
      {
        "category": "external",
        "summary": "Recommended Cybersecurity Best Practices",
        "url": "https://www.se.com/us/en/download/document/7EN52-0390"
      },
      {
        "category": "external",
        "summary": "Revenera Advisory",
        "url": "https://community.revenera.com/s/article/cve-2024-2658-flexnet-publisher-potential-local-privilege-escalation-issue"
      },
      {
        "category": "external",
        "summary": "ZDI Advisory",
        "url": "https://www.zerodayinitiative.com/advisories/ZDI-24-359/"
      }
    ],
    "title": "FlexNet Publisher Vulnerability",
    "tracking": {
      "current_release_date": "2025-11-11T08:00:00.000Z",
      "generator": {
        "date": "2025-11-07T12:20:16.407Z",
        "engine": {
          "name": "Schneider Electric CSAF Generator",
          "version": "1.2"
        }
      },
      "id": "SEVD-2025-014-07",
      "initial_release_date": "2025-01-14T07:00:00.000Z",
      "revision_history": [
        {
          "date": "2025-01-14T07:00:00.000Z",
          "number": "1.0.0",
          "summary": "Original Release"
        },
        {
          "date": "2025-02-11T06:00:00.000Z",
          "number": "2.0.0",
          "summary": "A remediation is available for the EcoStruxure\u2122 Process Expert offer. The EcoStruxure\u2122 Process Expert for AVEVA System Platform offer is added to the \u201cAffected Product and Versions\u201d section"
        },
        {
          "date": "2025-07-08T04:00:00.000Z",
          "number": "3.0.0",
          "summary": "Pro-face BLUE is added to the \u201cAffected Product and Versions\u201d section. Remediations are now available for EcoStruxure\u2122Control Expert, EcoStruxure\u2122 Operator Terminal Expert and Pro-face BLUE offers. Updated the link to the fix of EcoStruxure\u2122 Control Expert Asset Link offer"
        },
        {
          "date": "2025-10-14T07:00:00.000Z",
          "number": "4.0.0",
          "summary": "A remediation is now available for Zelio Soft 2 and EcoStruxure\u2122 OPC UA Server Expert offers"
        },
        {
          "date": "2025-11-11T08:00:00.000Z",
          "number": "5.0.0",
          "summary": "CVE, CWE, \u0026 CVSS Score information was added."
        }
      ],
      "status": "final",
      "version": "5.0.0"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c16.2",
                "product": {
                  "name": "Schneider Electric EcoStruxure\u2122 Control Expert Versions prior to V16.2",
                  "product_id": "1"
                }
              }
            ],
            "category": "product_name",
            "name": "EcoStruxure\u2122 Control Expert"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c2023 (v4.8.0.5715)",
                "product": {
                  "name": "Schneider Electric EcoStruxure\u2122 Process Expert Versions prior to 2023 (v4.8.0.5715)",
                  "product_id": "2"
                }
              }
            ],
            "category": "product_name",
            "name": "EcoStruxure\u2122 Process Expert"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003cSV2.01SP3",
                "product": {
                  "name": "EcoStruxure\u2122 OPC UA Server Expert Versions prior to SV2.01SP3",
                  "product_id": "3"
                }
              },
              {
                "category": "product_version_range",
                "name": "SV2.01SP3",
                "product": {
                  "name": "EcoStruxure\u2122 OPC UA Server Expert Version SV2.01SP3",
                  "product_id": "23"
                }
              }
            ],
            "category": "product_name",
            "name": "EcoStruxure\u2122 OPC UA Server Expert"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c4.0 SP1",
                "product": {
                  "name": "Schneider Electric EcoStruxure\u2122 Control Expert Asset Link Versions prior to V4.0 SP1",
                  "product_id": "4"
                }
              }
            ],
            "category": "product_name",
            "name": "EcoStruxure\u2122 Control Expert Asset Link"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "Schneider Electric EcoStruxure\u2122 Machine SCADA Expert Asset Link All versions",
                  "product_id": "5"
                }
              }
            ],
            "category": "product_name",
            "name": "EcoStruxure\u2122 Machine SCADA Expert Asset Link"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c7.0.18",
                "product": {
                  "name": "Schneider Electric EcoStruxure\u2122 Architecture Builder Versions prior to V7.0.18",
                  "product_id": "6"
                }
              }
            ],
            "category": "product_name",
            "name": "EcoStruxure\u2122 Architecture Builder"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c4.0",
                "product": {
                  "name": "Schneider Electric EcoStruxure\u2122 Operator Terminal Expert Versions prior to V4.0",
                  "product_id": "7"
                }
              }
            ],
            "category": "product_name",
            "name": "EcoStruxure\u2122 Operator Terminal Expert"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c6.3SP1 HF1",
                "product": {
                  "name": "Schneider Electric Vijeo Designer Version prior to V6.3SP1 HF1",
                  "product_id": "8"
                }
              }
            ],
            "category": "product_name",
            "name": "Vijeo Designer"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "Schneider Electric EcoStruxure\u2122 Machine Expert including EcoStruxure\u2122 Machine Expert Safety All versions",
                  "product_id": "9"
                }
              }
            ],
            "category": "product_name",
            "name": "EcoStruxure\u2122 Machine Expert including EcoStruxure\u2122 Machine Expert Safety"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "Schneider Electric EcoStruxure\u2122 Machine Expert Twin All versions",
                  "product_id": "10"
                }
              }
            ],
            "category": "product_name",
            "name": "EcoStruxure\u2122 Machine Expert Twin"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c5.4.3",
                "product": {
                  "name": "Zelio Soft 2 Versions prior to v5.4.3",
                  "product_id": "11"
                }
              },
              {
                "category": "product_version",
                "name": "5.4.3",
                "product": {
                  "name": "Zelio Soft 2 Version v5.4.3",
                  "product_id": "22"
                }
              }
            ],
            "category": "product_name",
            "name": "Zelio Soft 2"
          },
          {
            "branches": [
              {
                "category": "product_version",
                "name": "16.2",
                "product": {
                  "name": "Schneider Electric EcoStruxure\u2122 Control Expert Version V16.2",
                  "product_id": "12"
                }
              }
            ],
            "category": "product_name",
            "name": "EcoStruxure\u2122 Control Expert"
          },
          {
            "branches": [
              {
                "category": "product_version",
                "name": "7.0.18",
                "product": {
                  "name": "Schneider Electric EcoStruxure\u2122 Architecture Builder Version V7.0.18",
                  "product_id": "13"
                }
              }
            ],
            "category": "product_name",
            "name": "EcoStruxure\u2122 Architecture Builder"
          },
          {
            "branches": [
              {
                "category": "product_version",
                "name": "4.0SP1",
                "product": {
                  "name": "Schneider Electric EcoStruxure\u2122 Control Expert Asset Link Version V4.0SP1",
                  "product_id": "14"
                }
              }
            ],
            "category": "product_name",
            "name": "EcoStruxure\u2122 Control Expert Asset Link"
          },
          {
            "branches": [
              {
                "category": "product_version",
                "name": "6.3SP1 HF1",
                "product": {
                  "name": "Schneider Electric Vijeo Designer Version V6.3SP1 HF1",
                  "product_id": "15"
                }
              }
            ],
            "category": "product_name",
            "name": "Vijeo Designer"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "Schneider Electric EcoStruxure\u2122 Process Expert for AVEVA System Platform All versions",
                  "product_id": "16"
                }
              }
            ],
            "category": "product_name",
            "name": "EcoStruxure\u2122 Process Expert for AVEVA System Platform"
          },
          {
            "branches": [
              {
                "category": "product_version",
                "name": "2023 (v4.8.0.5715)",
                "product": {
                  "name": "Schneider Electric EcoStruxure\u2122 Process Expert Version 2023 (v4.8.0.5715)",
                  "product_id": "17"
                }
              }
            ],
            "category": "product_name",
            "name": "EcoStruxure\u2122 Process Expert 2023"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c4.0",
                "product": {
                  "name": "Schneider Electric Pro-face BLUE Versions prior to V4.0",
                  "product_id": "18"
                }
              }
            ],
            "category": "product_name",
            "name": "Pro-face BLUE"
          },
          {
            "branches": [
              {
                "category": "product_version",
                "name": "4.0",
                "product": {
                  "name": "Schneider Electric Pro-face BLUE Version V4.0",
                  "product_id": "19"
                }
              }
            ],
            "category": "product_name",
            "name": "Pro-face BLUE"
          },
          {
            "branches": [
              {
                "category": "product_version",
                "name": "4.0",
                "product": {
                  "name": "Schneider Electric EcoStruxure\u2122 Operator Terminal Expert Version V4.0",
                  "product_id": "20"
                }
              }
            ],
            "category": "product_name",
            "name": "EcoStruxure\u2122 Operator Terminal Expert"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c2023",
                "product": {
                  "name": "Schneider Electric EcoStruxure\u2122 Process Expert Versions prior to 2023",
                  "product_id": "21"
                }
              }
            ],
            "category": "product_name",
            "name": "EcoStruxure\u2122 Process Expert"
          }
        ],
        "category": "vendor",
        "name": "Schneider Electric"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2024-2658",
      "cwe": {
        "id": "CWE-427",
        "name": "Uncontrolled Search Path Element"
      },
      "notes": [
        {
          "category": "details",
          "text": "Vulnerability disclosed by Revenera group in FlexNet Publisher impact Schneider Electric software. \nAdditional information about the vulnerability CVE-2024-2658 can be found in the Revenera Advisory at:\nhttps://community.revenera.com/s/article/cve-2024-2658-flexnet-publisher-potential-local-privilege-escalation-issue",
          "title": "Vulnerability Details"
        }
      ],
      "product_status": {
        "fixed": [
          "12",
          "13",
          "14",
          "15",
          "17",
          "19",
          "20",
          "22",
          "23"
        ],
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "16",
          "18",
          "21"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Version 16.2 of EcoStruxure\u2122 Control Expert includes a fix for this vulnerability and is \r\navailable for download here:\r\nhttps://www.se.com/ww/en/product-range/548-ecostruxure-control-expert-unity-pro/ \r\nReboot the computer after installation is completed.",
          "product_ids": [
            "1"
          ],
          "restart_required": {
            "category": "system"
          },
          "url": "https://www.se.com/ww/en/product-range/548-ecostruxure-control-expert-unity-pro/"
        },
        {
          "category": "vendor_fix",
          "details": "Version V7.0.18 of EcoStruxure\u2122 Architecture Builder includes a fix for this vulnerability\r\nand is available for download here:\r\nhttps://www.se.com/ww/en/product-range/195445393-ecostruxure-architecture-builder/ -\r\nsoftware-and-firmware",
          "product_ids": [
            "6"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://www.se.com/ww/en/product-range/195445393-ecostruxure-architecture-builder/#software-and-firmware"
        },
        {
          "category": "vendor_fix",
          "details": "Version V4.0SP1 of EcoStruxure\u2122 Control Expert Asset Link includes a fix for this \r\nvulnerability and is available for download here:\r\nhttps://www.se.com/ww/en/download/document/ECALV40SP1/",
          "product_ids": [
            "4"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://www.se.com/ww/en/product-range/548-ecostruxure-control-expert-unity-pro/"
        },
        {
          "category": "vendor_fix",
          "details": "Version V6.3SP1 HF1 of Vijeo Designer includes a fix for this vulnerability. Please contact \r\nyour Schneider Electric Customer Support https://www.se.com/ww/en/work/support/country-selector/contact-us.jsp  to get Vijeo Designer version V6.3SP1 HF1\r\nsoftware.",
          "product_ids": [
            "8"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "mitigation",
          "details": "Schneider Electric is establishing a remediation plan for all \r\nfuture versions of the following that will include a fix for this\r\nvulnerability:\r\n\u2022 EcoStruxure\u2122 Process Expert\r\n\u2022 EcoStruxure\u2122 OPC UA Server Expert\r\n\u2022 EcoStruxure\u2122 Machine SCADA Expert - Asset \r\nLink\r\n\u2022 EcoStruxure\u2122 Operator Terminal Expert\r\n\u2022 EcoStruxure\u2122 Machine Expert including \r\nEcoStruxure\u2122 Machine Expert Safety\r\n\u2022 EcoStruxure\u2122 Machine Expert Twin\r\n\u2022 Zelio Soft 2\r\nWe will update this document when the remediation is \r\navailable. Until then, customers should immediately apply \r\nthe following mitigations to reduce the risk of exploit:\r\n\u2022 Limit authenticated user access to the workstation \r\nand implement existing User Account Control \r\npractices.\r\n\u2022 Follow workstation, network and site-hardening \r\nguidelines in the Recommended Cybersecurity \r\nBest Practices guide available for download here https://www.se.com/ww/en/download/document/7EN52-0390/?ssr=true .",
          "product_ids": [
            "1",
            "2",
            "4",
            "5",
            "6",
            "8",
            "9",
            "10",
            "16"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://www.se.com/ww/en/download/document/7EN52-0390/?ssr=true"
        },
        {
          "category": "mitigation",
          "details": "If customers choose not to apply the remediation provided above, they should immediately apply the following\r\nmitigations to reduce the risk of exploit:\r\n\u2022 Limit authenticated user access to the workstation and implement existing User Account Control\r\npractices.\r\n\u2022 Follow workstation, network and site-hardening guidelines in the Recommended Cybersecurity Best\r\nPractices guide available for download here.",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "11",
            "18",
            "21"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://www.se.com/ww/en/download/document/7EN52-0390/?ssr=true"
        },
        {
          "category": "vendor_fix",
          "details": "Version 2023 (v4.8.0.5715) of EcoStruxure\u2122 Process Expert includes a fix for this \r\nvulnerability and is available for download here:\r\nhttps://www.se.com/ww/en/product-country-selector/?pageType=productrange\u0026\r\nsourceId=65406 \r\nUninstall previous version 2023 (v4.8.0.5115) before installing Version 2023 \r\n(v4.8.0.5715).\r\nVersion string can be found on engineering server console.",
          "product_ids": [
            "2"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://www.se.com/ww/en/product-country-selector/?pageType=product-range\u0026sourceId=65406"
        },
        {
          "category": "vendor_fix",
          "details": "Version 2023 (v4.8.0.5715) of EcoStruxure\u2122 Process Expert includes a fix for \r\nthis vulnerability and is available for download here:\r\nhttps://www.se.com/ww/en/product-country-selector/?pageType=product-range\u0026sourceId=65406",
          "product_ids": [
            "21"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://www.se.com/ww/en/product-country-selector/?pageType=product-range\u0026sourceId=65406"
        },
        {
          "category": "vendor_fix",
          "details": "Version 4.0 of EcoStruxure\u2122 Operator Terminal Expert includes a fix for this \r\nvulnerability and is available for download here: \r\nhttps://www.se.com/ww/en/product-range/62621-ecostruxure-operator-terminal-expert/#software-and-firmware",
          "product_ids": [
            "7"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://www.se.com/ww/en/product-range/62621-ecostruxure-operator-terminal-expert/#software-and-firmware"
        },
        {
          "category": "vendor_fix",
          "details": "Version 4.0 of Pro-face BLUE includes a fix for this vulnerability and is available \r\nfor download here:\r\nhttps://www.proface.com/en/hmi_design_studio/blue/page/installer",
          "product_ids": [
            "18"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://www.proface.com/en/hmi_design_studio/blue/page/installer"
        },
        {
          "category": "vendor_fix",
          "details": "Version 5.4.3 of Zelio Soft 2 includes a fix for this vulnerability and is available for download here:\r\nhttps://www.se.com/ww/en/product-range/542-zelio-soft/#software-and-firmware",
          "product_ids": [
            "11"
          ],
          "restart_required": {
            "category": "service"
          },
          "url": "https://www.se.com/ww/en/product-range/542-zelio-soft/#software-and-firmware"
        },
        {
          "category": "vendor_fix",
          "details": "Version SV2.01SP3 of EcoStruxure\u2122 OPC UA Server Expert includes a fix for this vulnerability and is available for download here:\r\nhttps://www.se.com/ww/en/product-range/66388-ecostruxure-opc-ua-server-expert/#software-and-firmware",
          "product_ids": [
            "3"
          ],
          "restart_required": {
            "category": "system"
          },
          "url": "https://www.se.com/ww/en/product-range/66388-ecostruxure-opc-ua-server-expert/#software-and-firmware"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "16",
            "18",
            "21"
          ]
        }
      ],
      "title": "CVE-2024-2658"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…