SEVD-2021-103-01
Vulnerability from csaf_se - Published: 2021-04-13 11:17 - Updated: 2022-11-08 11:17Summary
C-Bus Toolkit and C-Gate Server
Notes
General Security Recommendations
We strongly recommend the following industry cybersecurity best practices.
https://www.se.com/us/en/download/document/7EN52-0390/
* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.
* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.
* Place all controllers in locked cabinets and never leave them in the “Program” mode.
* Never connect programming software to any network other than the network intended for that device.
* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.
* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.
* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.
* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.
For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.
For More Information
This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.
For further information related to cybersecurity in Schneider Electric’s products, visit the company’s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp
LEGAL DISCLAIMER
THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION
About Schneider Electric
At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.
We provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.
We are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.
www.se.com
Overview
Schneider Electric is aware of multiple vulnerabilities in its C-Bus Toolkit and C-Gate server products.
The C-Bus Toolkit product, which includes C-Gate Server, is an application you run on your personal computer to configure and commission C-Bus Installations.
Failure to apply the remediations provided below may risk remote code execution attack, which could result in an attacker having remote access to the computer.
November 2022 Update: The CWE for CVE-2021-22716 has been updated (marked in red). No additional action is required for customers who have already followed the remediation instructions provided below.
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of multiple vulnerabilities in its C-Bus Toolkit and C-Gate server products.\r\nThe C-Bus Toolkit product, which includes C-Gate Server, is an application you run on your personal computer to configure and commission C-Bus Installations.\r\nFailure to apply the remediations provided below may risk remote code execution attack, which could result in an attacker having remote access to the computer.\r\nNovember 2022 Update: The CWE for CVE-2021-22716 has been updated (marked in red). No additional action is required for customers who have already followed the remediation instructions provided below.",
"title": "Overview"
}
],
"publisher": {
"category": "vendor",
"contact_details": "cybersecurity@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "C-Bus Toolkit and C-Gate Server - SEVD-2021-103-01 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-103-01_C-Bus_Toolkit_C-Gate_Server_Security_Notification.pdf"
},
{
"category": "self",
"summary": "C-Bus Toolkit and C-Gate Server - SEVD-2021-103-01 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2021-103-01.json"
},
{
"category": "self",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
}
],
"title": "C-Bus Toolkit and C-Gate Server",
"tracking": {
"current_release_date": "2022-11-08T11:17:13.000Z",
"generator": {
"date": "2022-11-10T12:00:25.322Z",
"engine": {
"name": "Schneider Electric CSAF Generator",
"version": "2.0.0"
}
},
"id": "SEVD-2021-103-01",
"initial_release_date": "2021-04-13T11:17:13.000Z",
"revision_history": [
{
"date": "2021-04-13T11:17:13.000Z",
"number": "1.0.0",
"summary": "Original Release"
},
{
"date": "2021-06-08T11:17:13.000Z",
"number": "2.0.0",
"summary": "Added CVE-2021-22748"
},
{
"date": "2021-09-14T11:17:13.000Z",
"number": "3.0.0",
"summary": "\u2022 C-Gate Server added as an affected product of CVE-2021-22720\r\n\u2022 CVE-2021-22796 added\r\n\u2022 Updated the previously provided remediation\r\n\u2022 Added Tenable Security to the acknowledgement section"
},
{
"date": "2022-11-08T11:17:13.000Z",
"number": "3.1.0",
"summary": "The CWE for CVE-2021-22716 has been updated (marked in red). No additional action is required for customers who have already followed the remediation instructions provided below."
}
],
"status": "final",
"version": "3.1.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c1.15.9",
"product": {
"name": "Schneider Electric C-Bus Toolkit \u003c1.15.9",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "C-Bus Toolkit"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c2.11.7",
"product": {
"name": "Schneider Electric C-Gate Server \u003c2.11.7",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "C-Gate Server"
},
{
"branches": [
{
"category": "product_version",
"name": "1.15.10",
"product": {
"name": "Schneider Electric C-Bus Toolkit 1.15.10",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "C-Bus Toolkit"
},
{
"branches": [
{
"category": "product_version",
"name": "2.11.8",
"product": {
"name": "Schneider Electric C-Gate Server 2.11.8",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "C-Gate Server"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"Simon Zuckerbraun"
],
"organization": "Trend Micro Zero Day Initiative"
}
],
"cve": "CVE-2021-22716",
"cwe": {
"id": "CWE-732",
"name": "Incorrect Permission Assignment for Critical Resource"
},
"notes": [
{
"category": "description",
"text": "A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could allow remote code execution when an unprivileged user modifies a file.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"3",
"4"
],
"known_affected": [
"1",
"2"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 1.15.10 of the C-Bus Toolkit product, which contains the C-Gate Server, includes a fix for these vulnerabilities and is available for download here:",
"product_ids": [
"1"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/2216-spacelogic-c-bus-home-automation-system/?parent-subcategory-id=88010\u0026filter=business-5-residential-and-small-business----software-firmware-tab#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "Version 2.11.8 of the C-Gate Server product is also available at the link below.",
"product_ids": [
"2"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/2216-spacelogic-c-bus-home-automation-system/?parent-subcategory-id=88010\u0026filter=business-5-residential-and-small-business----software-firmware-tab#software-and-firmware"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"1",
"2"
]
}
],
"title": "CVE-2021-22716"
},
{
"acknowledgments": [
{
"names": [
"rgod "
],
"organization": "Trend Micro Zero Day Initiative"
}
],
"cve": "CVE-2021-22717",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"category": "description",
"text": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could allow a remote code execution when processing config files.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"3",
"4"
],
"known_affected": [
"1",
"2"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 1.15.10 of the C-Bus Toolkit product, which contains the C-Gate Server, includes a fix for these vulnerabilities and is available for download here:",
"product_ids": [
"1"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/2216-spacelogic-c-bus-home-automation-system/?parent-subcategory-id=88010\u0026filter=business-5-residential-and-small-business----software-firmware-tab#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "Version 2.11.8 of the C-Gate Server product is also available at the link below.",
"product_ids": [
"2"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/2216-spacelogic-c-bus-home-automation-system/?parent-subcategory-id=88010\u0026filter=business-5-residential-and-small-business----software-firmware-tab#software-and-firmware"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"1",
"2"
]
}
],
"title": "CVE-2021-22717"
},
{
"acknowledgments": [
{
"names": [
"rgod "
],
"organization": "Trend Micro Zero Day Initiative"
}
],
"cve": "CVE-2021-22718",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"category": "description",
"text": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could allow a remote code execution when restoring project files.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"3",
"4"
],
"known_affected": [
"1",
"2"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 1.15.10 of the C-Bus Toolkit product, which contains the C-Gate Server, includes a fix for these vulnerabilities and is available for download here:",
"product_ids": [
"1"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/2216-spacelogic-c-bus-home-automation-system/?parent-subcategory-id=88010\u0026filter=business-5-residential-and-small-business----software-firmware-tab#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "Version 2.11.8 of the C-Gate Server product is also available at the link below.",
"product_ids": [
"2"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/2216-spacelogic-c-bus-home-automation-system/?parent-subcategory-id=88010\u0026filter=business-5-residential-and-small-business----software-firmware-tab#software-and-firmware"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"1",
"2"
]
}
],
"title": "CVE-2021-22718"
},
{
"acknowledgments": [
{
"names": [
"rgod "
],
"organization": "Trend Micro Zero Day Initiative"
}
],
"cve": "CVE-2021-22719",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"category": "description",
"text": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could allow a remote code execution when a file is uploaded.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"3",
"4"
],
"known_affected": [
"1",
"2"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 1.15.10 of the C-Bus Toolkit product, which contains the C-Gate Server, includes a fix for these vulnerabilities and is available for download here:",
"product_ids": [
"1"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/2216-spacelogic-c-bus-home-automation-system/?parent-subcategory-id=88010\u0026filter=business-5-residential-and-small-business----software-firmware-tab#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "Version 2.11.8 of the C-Gate Server product is also available at the link below.",
"product_ids": [
"2"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/2216-spacelogic-c-bus-home-automation-system/?parent-subcategory-id=88010\u0026filter=business-5-residential-and-small-business----software-firmware-tab#software-and-firmware"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"1",
"2"
]
}
],
"title": "CVE-2021-22719"
},
{
"acknowledgments": [
{
"names": [
"rgod"
],
"organization": "Trend Micro Zero Day Initiative"
},
{
"organization": "Tenable Security"
}
],
"cve": "CVE-2021-22720",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"category": "description",
"text": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could allow a remote code execution when restoring a project.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"3",
"4"
],
"known_affected": [
"1",
"2"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 1.15.10 of the C-Bus Toolkit product, which contains the C-Gate Server, includes a fix for these vulnerabilities and is available for download here:",
"product_ids": [
"1"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/2216-spacelogic-c-bus-home-automation-system/?parent-subcategory-id=88010\u0026filter=business-5-residential-and-small-business----software-firmware-tab#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "Version 2.11.8 of the C-Gate Server product is also available at the link below.",
"product_ids": [
"2"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/2216-spacelogic-c-bus-home-automation-system/?parent-subcategory-id=88010\u0026filter=business-5-residential-and-small-business----software-firmware-tab#software-and-firmware"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
"products": [
"1",
"2"
]
}
],
"title": "CVE-2021-22720"
},
{
"acknowledgments": [
{
"names": [
"Simon Zuckerbraun"
],
"organization": "Trend Micro Zero Day Initiative"
}
],
"cve": "CVE-2021-22748",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"category": "description",
"text": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could allow a remote code execution when a file is saved.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"3",
"4"
],
"known_affected": [
"1",
"2"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 1.15.10 of the C-Bus Toolkit product, which contains the C-Gate Server, includes a fix for these vulnerabilities and is available for download here:",
"product_ids": [
"1"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/2216-spacelogic-c-bus-home-automation-system/?parent-subcategory-id=88010\u0026filter=business-5-residential-and-small-business----software-firmware-tab#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "Version 2.11.8 of the C-Gate Server product is also available at the link below.",
"product_ids": [
"2"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/2216-spacelogic-c-bus-home-automation-system/?parent-subcategory-id=88010\u0026filter=business-5-residential-and-small-business----software-firmware-tab#software-and-firmware"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1",
"2"
]
}
],
"title": "CVE-2021-22748"
},
{
"acknowledgments": [
{
"organization": "Tenable Security"
}
],
"cve": "CVE-2021-22796",
"cwe": {
"id": "CWE-287",
"name": "Improper Authentication"
},
"notes": [
{
"category": "description",
"text": "A CWE-287:Improper Authentication vulnerability exists that could allow remote code execution when a malicious file is uploaded.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"3",
"4"
],
"known_affected": [
"1",
"2"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 1.15.10 of the C-Bus Toolkit product, which contains the C-Gate Server, includes a fix for these vulnerabilities and is available for download here:",
"product_ids": [
"1"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/2216-spacelogic-c-bus-home-automation-system/?parent-subcategory-id=88010\u0026filter=business-5-residential-and-small-business----software-firmware-tab#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "Version 2.11.8 of the C-Gate Server product is also available at the link below.",
"product_ids": [
"2"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/2216-spacelogic-c-bus-home-automation-system/?parent-subcategory-id=88010\u0026filter=business-5-residential-and-small-business----software-firmware-tab#software-and-firmware"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1",
"2"
]
}
],
"title": "CVE-2021-22796"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…