ICSA-17-180-01A

Vulnerability from csaf_cisa - Published: 2017-06-29 00:00 - Updated: 2017-07-11 00:00
Summary
ICSA-17-180-01A_Siemens SIMATIC Industrial PCs, SINUMERIK Panel Control Unit, and SIMOTION P320 (Update A)
Notes
CISA Disclaimer: This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Summary: Maksim Malyutin from Embedi reported this issue to Intel.
Exploitability: No known public exploits specifically target this vulnerability.
CWE-269 - Improper Privilege Management
Affected products
Product Identifier Version Remediation
SINUMERIK Panel Control Unit (PCU): (Intel Core i5 Intel Core i7 and Intel XEON)
Siemens / SINUMERIK Panel Control Unit (PCU)
Intel Core i5 Intel Core i7 | Intel XEON
Mitigation
Acknowledgments
Embedi Maksim Malyutin

{
  "document": {
    "acknowledgments": [
      {
        "names": [
          "Maksim Malyutin"
        ],
        "organization": "Embedi",
        "summary": "reporting this issue to Intel"
      }
    ],
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited",
      "tlp": {
        "label": "WHITE"
      }
    },
    "lang": "en-US",
    "notes": [
      {
        "category": "general",
        "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
        "title": "CISA Disclaimer"
      },
      {
        "category": "summary",
        "text": "Maksim Malyutin from Embedi reported this issue to Intel.",
        "title": "Summary"
      },
      {
        "category": "other",
        "text": "No known public exploits specifically target this vulnerability.",
        "title": "Exploitability"
      }
    ],
    "publisher": {
      "category": "coordinator",
      "contact_details": "CISAservicedesk@cisa.dhs.gov",
      "name": "CISA",
      "namespace": "https://www.cisa.gov/"
    },
    "references": [
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-17-180-01A JSON",
        "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2017/icsa-17-180-01a.json"
      },
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-17-180-01A Web Version",
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-17-180-01a"
      }
    ],
    "title": "ICSA-17-180-01A_Siemens SIMATIC Industrial PCs, SINUMERIK Panel Control Unit, and SIMOTION P320 (Update A)",
    "tracking": {
      "current_release_date": "2017-07-11T00:00:00.000000Z",
      "generator": {
        "engine": {
          "name": "CISA USCert CSAF Generator",
          "version": "1"
        }
      },
      "id": "ICSA-17-180-01A",
      "initial_release_date": "2017-06-29T00:00:00.000000Z",
      "revision_history": [
        {
          "date": "2017-06-29T00:00:00.000000Z",
          "legacy_version": "Initial",
          "number": "1",
          "summary": "ICSA-17-180-01 Siemens SIMATIC Industrial PCs, SINUMERIK Panel Control Unit (PCU), SIMOTION P320"
        },
        {
          "date": "2017-07-11T00:00:00.000000Z",
          "legacy_version": "A",
          "number": "2",
          "summary": "ICSA-17-180-01A Siemens products with Intel processors (Update A)"
        }
      ],
      "status": "final",
      "version": "2"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version",
                "name": "Intel Core i5 Intel Core i7 | Intel XEON",
                "product": {
                  "name": "SINUMERIK Panel Control Unit (PCU): (Intel Core i5 Intel Core i7 and Intel XEON)",
                  "product_id": "CSAFPID-0001"
                }
              }
            ],
            "category": "product_name",
            "name": "SINUMERIK Panel Control Unit (PCU)"
          },
          {
            "branches": [
              {
                "category": "product_version",
                "name": "Intel Core i5 Intel Core i7 | Intel XEON",
                "product": {
                  "name": "SIMATIC Industrial PCs: (Intel Core i5 Intel Core i7 and Intel XEON)",
                  "product_id": "CSAFPID-0002"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC Industrial PCs"
          },
          {
            "branches": [
              {
                "category": "product_version",
                "name": "Intel Core i5 Intel Core i7 | Intel XEON",
                "product": {
                  "name": "SIMOTION P320: (Intel Core i5 Intel Core i7 and Intel XEON)",
                  "product_id": "CSAFPID-0003"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMOTION P320"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2017-5689",
      "cwe": {
        "id": "CWE-269",
        "name": "Improper Privilege Management"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Unprivileged local or remote attackers can gain system privileges to provisioned Intel manageability SKUs: Intel Active Management Technology (AMT), Intel Standard Manageability (ISM) and Intel Small Business Technology (SBT).CVE-2017-5689 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "references": [
        {
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "Siemens has provided firmware updates for the affected industrial PCs to address this vulnerability. These updates can be found on their web site at the following location:",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003"
          ]
        }
      ],
      "title": "CVE-2017-5689"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.