gsd-2024-3875
Vulnerability from gsd
Modified
2024-04-17 05:02
Details
A vulnerability was found in Tenda F1202 1.2.0.20(408). It has been rated as critical. This issue affects the function fromNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260909 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Aliases



{
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2024-3875"
      ],
      "details": "A vulnerability was found in Tenda F1202 1.2.0.20(408). It has been rated as critical. This issue affects the function fromNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260909 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.",
      "id": "GSD-2024-3875",
      "modified": "2024-04-17T05:02:02.029903Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "cna@vuldb.com",
        "ID": "CVE-2024-3875",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "F1202",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "1.2.0.20(408)"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Tenda"
            }
          ]
        }
      },
      "credits": [
        {
          "lang": "en",
          "value": "wxhwxhwxh_mie (VulDB User)"
        }
      ],
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "A vulnerability was found in Tenda F1202 1.2.0.20(408). It has been rated as critical. This issue affects the function fromNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260909 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
          },
          {
            "lang": "deu",
            "value": "Eine Schwachstelle wurde in Tenda F1202 1.2.0.20(408) ausgemacht. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion fromNatlimit der Datei /goform/Natlimit. Dank der Manipulation des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
          }
        ]
      },
      "impact": {
        "cvss": [
          {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "cweId": "CWE-121",
                "lang": "eng",
                "value": "CWE-121 Stack-based Buffer Overflow"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://vuldb.com/?id.260909",
            "refsource": "MISC",
            "url": "https://vuldb.com/?id.260909"
          },
          {
            "name": "https://vuldb.com/?ctiid.260909",
            "refsource": "MISC",
            "url": "https://vuldb.com/?ctiid.260909"
          },
          {
            "name": "https://vuldb.com/?submit.312817",
            "refsource": "MISC",
            "url": "https://vuldb.com/?submit.312817"
          },
          {
            "name": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1202/fromNatlimit.md",
            "refsource": "MISC",
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1202/fromNatlimit.md"
          }
        ]
      }
    },
    "nvd.nist.gov": {
      "cve": {
        "descriptions": [
          {
            "lang": "en",
            "value": "A vulnerability was found in Tenda F1202 1.2.0.20(408). It has been rated as critical. This issue affects the function fromNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260909 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
          },
          {
            "lang": "es",
            "value": "Se encontr\u00f3 una vulnerabilidad en Tenda F1202 1.2.0.20(408). Ha sido calificada como cr\u00edtica. Este problema afecta la funci\u00f3n fromNatlimit del archivo /goform/Natlimit. La manipulaci\u00f3n de la p\u00e1gina de argumentos provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque puede iniciarse de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. A esta vulnerabilidad se le asign\u00f3 el identificador VDB-260909. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera."
          }
        ],
        "id": "CVE-2024-3875",
        "lastModified": "2024-04-17T12:48:31.863",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "HIGH",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "integrityImpact": "COMPLETE",
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              "exploitabilityScore": 8.0,
              "impactScore": 10.0,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "cna@vuldb.com",
              "type": "Secondary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 5.9,
              "source": "cna@vuldb.com",
              "type": "Secondary"
            }
          ]
        },
        "published": "2024-04-16T18:15:14.397",
        "references": [
          {
            "source": "cna@vuldb.com",
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1202/fromNatlimit.md"
          },
          {
            "source": "cna@vuldb.com",
            "url": "https://vuldb.com/?ctiid.260909"
          },
          {
            "source": "cna@vuldb.com",
            "url": "https://vuldb.com/?id.260909"
          },
          {
            "source": "cna@vuldb.com",
            "url": "https://vuldb.com/?submit.312817"
          }
        ],
        "sourceIdentifier": "cna@vuldb.com",
        "vulnStatus": "Awaiting Analysis",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-121"
              }
            ],
            "source": "cna@vuldb.com",
            "type": "Primary"
          }
        ]
      }
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.