gsd-2023-46142
Vulnerability from gsd
Modified
2023-12-13 01:20
Details
A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2023-46142", "id": "GSD-2023-46142" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2023-46142" ], "details": "A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices.", "id": "GSD-2023-46142", "modified": "2023-12-13T01:20:53.149043Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "info@cert.vde.com", "ID": "CVE-2023-46142", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "AXC F 1152", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "0", "version_value": "2024.0" } ] } }, { "product_name": "AXC F 2152", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "0", "version_value": "2024.0" } ] } }, { "product_name": "AXC F 3152", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "0", "version_value": "2024.0" } ] } }, { "product_name": "BPC 9102S", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "0", "version_value": "2024.0" } ] } }, { "product_name": "EPC 1502", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "0", "version_value": "2024.0" } ] } }, { "product_name": "EPC 1522", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "0", "version_value": "2024.0" } ] } }, { "product_name": "PLCnext Engineer", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "0", "version_value": "2024.0" } ] } }, { "product_name": "RFC 4072R", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "0", "version_value": "2024.0" } ] } }, { "product_name": "RFC 4072S", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "0", "version_value": "2024.0" } ] } } ] }, "vendor_name": "PHOENIX CONTACT" } ] } }, "credits": [ { "lang": "en", "value": "Reid Wightman of Dragos, Inc." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices." } ] }, "generator": { "engine": "Vulnogram 0.1.0-dev" }, "impact": { "cvss": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-732", "lang": "eng", "value": "CWE-732: Incorrect Permission Assignment for Critical Resource" } ] } ] }, "references": { "reference_data": [ { "name": "https://https://cert.vde.com/en/advisories/VDE-2023-056/", "refsource": "MISC", "url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/" } ] }, "source": { "advisory": "VDE-2023-056", "defect": [ "CERT@VDE#64609" ], "discovery": "EXTERNAL" } }, "nvd.nist.gov": { "cve": { "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:phoenixcontact:axc_f_1152_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9C72F7B2-43D1-43CB-B611-B57487E9AE53", "versionEndIncluding": "2024.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:phoenixcontact:axc_f_1152:-:*:*:*:*:*:*:*", "matchCriteriaId": "A2474BD7-C447-4E07-A628-C729E376943D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:phoenixcontact:axc_f_2152_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4EA16E9E-ADBB-4943-AE2D-7C49F882A809", "versionEndIncluding": "2024.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:phoenixcontact:axc_f_2152:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE2E6118-6587-444A-A143-9C3A1E6ED4FD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:phoenixcontact:axc_f_3152_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E28DCF3B-C26E-44BE-BCA1-0AED56326FC3", "versionEndIncluding": "2024.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:phoenixcontact:axc_f_3152:-:*:*:*:*:*:*:*", "matchCriteriaId": "57424998-4EAB-4682-BFC4-1D2A621514F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:phoenixcontact:bpc_9102s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A97B1250-2830-4EFC-9393-DF96E129E16D", "versionEndIncluding": "2024.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:phoenixcontact:bpc_9102s:-:*:*:*:*:*:*:*", "matchCriteriaId": "346E85EB-8800-40C7-A7DA-EA587CF90F08", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:phoenixcontact:epc_1502_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F8E7E962-9BA0-418B-8A43-541C5278C9ED", "versionEndIncluding": "2024.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:phoenixcontact:epc_1502:-:*:*:*:*:*:*:*", "matchCriteriaId": "85AF0A71-02C4-4CFF-A820-5C326F066024", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:phoenixcontact:epc_1522_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E3671BE8-A1DE-444E-9A24-5C86E4F0BBF1", "versionEndIncluding": "2024.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:phoenixcontact:epc_1522:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD531B6-09DA-4B4A-AA7C-C2A54B089C67", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:phoenixcontact:plcnext_engineer:*:*:*:*:*:*:*:*", "matchCriteriaId": "C6A5C5E9-4F2C-44BC-8B64-29D25C789643", "versionEndIncluding": "2024.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:phoenixcontact:rfc_4072r_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE1D89DD-1717-4E84-8A33-82AA29594E7D", "versionEndIncluding": "2024.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:phoenixcontact:rfc_4072r:-:*:*:*:*:*:*:*", "matchCriteriaId": "65D9C540-F273-4EA8-8FF6-95DF46B01D89", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:phoenixcontact:rfc_4072s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E633B5AB-BD27-461D-8083-20CC1C768D34", "versionEndIncluding": "2024.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:phoenixcontact:rfc_4072s:-:*:*:*:*:*:*:*", "matchCriteriaId": "0BF1EAD1-7C19-4A6E-BF87-EF3F7E526BD6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "descriptions": [ { "lang": "en", "value": "A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices." }, { "lang": "es", "value": "Una asignaci\u00f3n de permiso incorrecta para una vulnerabilidad de recursos cr\u00edticos en los productos PLCnext permite que un atacante remoto con privilegios bajos obtenga acceso completo a los dispositivos afectados." } ], "id": "CVE-2023-46142", "lastModified": "2023-12-21T17:15:15.170", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "info@cert.vde.com", "type": "Primary" } ] }, "published": "2023-12-14T14:15:42.983", "references": [ { "source": "info@cert.vde.com", "tags": [ "Broken Link" ], "url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/" } ], "sourceIdentifier": "info@cert.vde.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-732" } ], "source": "info@cert.vde.com", "type": "Primary" } ] } } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.