gsd-2023-46142
Vulnerability from gsd
Modified
2023-12-13 01:20
Details
A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices.
Aliases
Aliases



{
  "GSD": {
    "alias": "CVE-2023-46142",
    "id": "GSD-2023-46142"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2023-46142"
      ],
      "details": "A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices.",
      "id": "GSD-2023-46142",
      "modified": "2023-12-13T01:20:53.149043Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "info@cert.vde.com",
        "ID": "CVE-2023-46142",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "AXC F 1152",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c=",
                          "version_name": "0",
                          "version_value": "2024.0"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "AXC F 2152",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c=",
                          "version_name": "0",
                          "version_value": "2024.0"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "AXC F 3152",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c=",
                          "version_name": "0",
                          "version_value": "2024.0"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "BPC 9102S",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c=",
                          "version_name": "0",
                          "version_value": "2024.0"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "EPC 1502",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c=",
                          "version_name": "0",
                          "version_value": "2024.0"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "EPC 1522",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c=",
                          "version_name": "0",
                          "version_value": "2024.0"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "PLCnext Engineer",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c=",
                          "version_name": "0",
                          "version_value": "2024.0"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "RFC 4072R",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c=",
                          "version_name": "0",
                          "version_value": "2024.0"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "RFC 4072S",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c=",
                          "version_name": "0",
                          "version_value": "2024.0"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "PHOENIX CONTACT"
            }
          ]
        }
      },
      "credits": [
        {
          "lang": "en",
          "value": "Reid Wightman of Dragos, Inc."
        }
      ],
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices."
          }
        ]
      },
      "generator": {
        "engine": "Vulnogram 0.1.0-dev"
      },
      "impact": {
        "cvss": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "cweId": "CWE-732",
                "lang": "eng",
                "value": "CWE-732: Incorrect Permission Assignment for Critical Resource"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://https://cert.vde.com/en/advisories/VDE-2023-056/",
            "refsource": "MISC",
            "url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
          }
        ]
      },
      "source": {
        "advisory": "VDE-2023-056",
        "defect": [
          "CERT@VDE#64609"
        ],
        "discovery": "EXTERNAL"
      }
    },
    "nvd.nist.gov": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:phoenixcontact:axc_f_1152_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "9C72F7B2-43D1-43CB-B611-B57487E9AE53",
                    "versionEndIncluding": "2024.0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:phoenixcontact:axc_f_1152:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "A2474BD7-C447-4E07-A628-C729E376943D",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:phoenixcontact:axc_f_2152_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "4EA16E9E-ADBB-4943-AE2D-7C49F882A809",
                    "versionEndIncluding": "2024.0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:phoenixcontact:axc_f_2152:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "AE2E6118-6587-444A-A143-9C3A1E6ED4FD",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:phoenixcontact:axc_f_3152_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "E28DCF3B-C26E-44BE-BCA1-0AED56326FC3",
                    "versionEndIncluding": "2024.0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:phoenixcontact:axc_f_3152:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "57424998-4EAB-4682-BFC4-1D2A621514F4",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:phoenixcontact:bpc_9102s_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "A97B1250-2830-4EFC-9393-DF96E129E16D",
                    "versionEndIncluding": "2024.0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:phoenixcontact:bpc_9102s:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "346E85EB-8800-40C7-A7DA-EA587CF90F08",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:phoenixcontact:epc_1502_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F8E7E962-9BA0-418B-8A43-541C5278C9ED",
                    "versionEndIncluding": "2024.0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:phoenixcontact:epc_1502:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "85AF0A71-02C4-4CFF-A820-5C326F066024",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:phoenixcontact:epc_1522_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "E3671BE8-A1DE-444E-9A24-5C86E4F0BBF1",
                    "versionEndIncluding": "2024.0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:phoenixcontact:epc_1522:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "CBD531B6-09DA-4B4A-AA7C-C2A54B089C67",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:phoenixcontact:plcnext_engineer:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C6A5C5E9-4F2C-44BC-8B64-29D25C789643",
                    "versionEndIncluding": "2024.0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:phoenixcontact:rfc_4072r_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "FE1D89DD-1717-4E84-8A33-82AA29594E7D",
                    "versionEndIncluding": "2024.0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:phoenixcontact:rfc_4072r:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "65D9C540-F273-4EA8-8FF6-95DF46B01D89",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:phoenixcontact:rfc_4072s_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "E633B5AB-BD27-461D-8083-20CC1C768D34",
                    "versionEndIncluding": "2024.0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:phoenixcontact:rfc_4072s:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "0BF1EAD1-7C19-4A6E-BF87-EF3F7E526BD6",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "descriptions": [
          {
            "lang": "en",
            "value": "A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices."
          },
          {
            "lang": "es",
            "value": "Una asignaci\u00f3n de permiso incorrecta para una vulnerabilidad de recursos cr\u00edticos en los productos PLCnext permite que un atacante remoto con privilegios bajos obtenga acceso completo a los dispositivos afectados."
          }
        ],
        "id": "CVE-2023-46142",
        "lastModified": "2023-12-21T17:15:15.170",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 5.9,
              "source": "info@cert.vde.com",
              "type": "Primary"
            }
          ]
        },
        "published": "2023-12-14T14:15:42.983",
        "references": [
          {
            "source": "info@cert.vde.com",
            "tags": [
              "Broken Link"
            ],
            "url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
          }
        ],
        "sourceIdentifier": "info@cert.vde.com",
        "vulnStatus": "Analyzed",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-732"
              }
            ],
            "source": "info@cert.vde.com",
            "type": "Primary"
          }
        ]
      }
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.