On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS a specially crafted LLDP packet may lead to a high system load in the PROFINET stack. An attacker can cause failure of system services or a complete reboot.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2020-12521", "description": "On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS a specially crafted LLDP packet may lead to a high system load in the PROFINET stack. An attacker can cause failure of system services or a complete reboot.", "id": "GSD-2020-12521" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2020-12521" ], "details": "On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS a specially crafted LLDP packet may lead to a high system load in the PROFINET stack. An attacker can cause failure of system services or a complete reboot.", "id": "GSD-2020-12521", "modified": "2023-12-13T01:21:49.345758Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "AKA": "", "ASSIGNER": "info@cert.vde.com", "DATE_PUBLIC": "2020-12-17T09:00:00.000Z", "ID": "CVE-2020-12521", "STATE": "PUBLIC", "TITLE": "Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS: A specially crafted LLDP packet may lead to a high system load in the PROFINET stack." }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "AXC F 1152 (1151412)", "version": { "version_data": [ { "platform": "", "version_affected": "\u003c", "version_name": "", "version_value": "2021.0 LTS" } ] } }, { "product_name": "AXC F 2152 (2404267)", "version": { "version_data": [ { "platform": "", "version_affected": "\u003c", "version_name": "", "version_value": "2021.0 LTS" } ] } }, { "product_name": "AXC F 3152 (1069208)", "version": { "version_data": [ { "platform": "", "version_affected": "\u003c", "version_name": "", "version_value": "2021.0 LTS" } ] } }, { "product_name": "RFC 4072S (1051328", "version": { "version_data": [ { "platform": "", "version_affected": "\u003c", "version_name": "", "version_value": "2021.0 LTS" } ] } }, { "product_name": "AXC F 2152 Starterkit (1046568)", "version": { "version_data": [ { "platform": "", "version_affected": "\u003c", "version_name": "", "version_value": "2021.0 LTS" } ] } }, { "product_name": "PLCnext Technology Starterkit (1188165)", "version": { "version_data": [ { "platform": "", "version_affected": "\u003c", "version_name": "", "version_value": "2021.0 LTS" } ] } } ] }, "vendor_name": "Phoenix Contact" } ] } }, "configuration": [], "credit": [ { "lang": "eng", "value": "Phoenix Contact reported to CERT@VDE" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS a specially crafted LLDP packet may lead to a high system load in the PROFINET stack. An attacker can cause failure of system services or a complete reboot." } ] }, "exploit": [], "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-20 Improper Input Validation" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert.vde.com/en-us/advisories/vde-2020-049", "refsource": "CONFIRM", "url": "https://cert.vde.com/en-us/advisories/vde-2020-049" } ] }, "solution": [ { "lang": "eng", "value": "Phoenix Contact recommends affected users to upgrade to the current Firmware 2021.0 LTS or higher which fixes these vulnerabilities." } ], "source": { "advisory": "VDE-2020-049", "defect": [ "VDE-2020-049" ], "discovery": "EXTERNAL" }, "work_around": [ { "lang": "eng", "value": "Phoenix Contact recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note." } ] }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:phoenixcontact:plcnext_firmware:*:*:*:*:long_term_support:*:*:*", "cpe_name": [], "versionEndExcluding": "2021.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:phoenixcontact:axc_f_1152:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:phoenixcontact:plcnext_firmware:*:*:*:*:long_term_support:*:*:*", "cpe_name": [], "versionEndExcluding": "2021.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:phoenixcontact:axc_f_2152:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:phoenixcontact:plcnext_firmware:*:*:*:*:long_term_support:*:*:*", "cpe_name": [], "versionEndExcluding": "2021.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:phoenixcontact:axc_f_3152:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:phoenixcontact:plcnext_firmware:*:*:*:*:long_term_support:*:*:*", "cpe_name": [], "versionEndExcluding": "2021.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:phoenixcontact:rfc_4072s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:phoenixcontact:plcnext_firmware:*:*:*:*:long_term_support:*:*:*", "cpe_name": [], "versionEndExcluding": "2021.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:phoenixcontact:axc_f_2152_starterkit:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:phoenixcontact:plcnext_firmware:*:*:*:*:long_term_support:*:*:*", "cpe_name": [], "versionEndExcluding": "2021.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:phoenixcontact:plcnext_technology_starterkit:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "info@cert.vde.com", "ID": "CVE-2020-12521" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS a specially crafted LLDP packet may lead to a high system load in the PROFINET stack. An attacker can cause failure of system services or a complete reboot." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-20" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert.vde.com/en-us/advisories/vde-2020-049", "refsource": "CONFIRM", "tags": [ "Third Party Advisory" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-049" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 6.1, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6 } }, "lastModifiedDate": "2020-12-21T18:28Z", "publishedDate": "2020-12-17T23:15Z" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.