GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

GSD-2017-6079

Vulnerability from gsd - Updated: 2023-12-13 01:21
Details
The HTTP web-management application on Edgewater Networks Edgemarc appliances has a hidden page that allows for user-defined commands such as specific iptables routes, etc., to be set. You can use this page as a web shell essentially to execute commands, though you get no feedback client-side from the web application: if the command is valid, it executes. An example is the wget command. The page that allows this has been confirmed in firmware as old as 2006.
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2017-6079",
    "description": "The HTTP web-management application on Edgewater Networks Edgemarc appliances has a hidden page that allows for user-defined commands such as specific iptables routes, etc., to be set. You can use this page as a web shell essentially to execute commands, though you get no feedback client-side from the web application: if the command is valid, it executes. An example is the wget command. The page that allows this has been confirmed in firmware as old as 2006.",
    "id": "GSD-2017-6079"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2017-6079"
      ],
      "details": "The HTTP web-management application on Edgewater Networks Edgemarc appliances has a hidden page that allows for user-defined commands such as specific iptables routes, etc., to be set. You can use this page as a web shell essentially to execute commands, though you get no feedback client-side from the web application: if the command is valid, it executes. An example is the wget command. The page that allows this has been confirmed in firmware as old as 2006.",
      "id": "GSD-2017-6079",
      "modified": "2023-12-13T01:21:10.183120Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "cve@mitre.org",
        "ID": "CVE-2017-6079",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "n/a",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "n/a"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "n/a"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "The HTTP web-management application on Edgewater Networks Edgemarc appliances has a hidden page that allows for user-defined commands such as specific iptables routes, etc., to be set. You can use this page as a web shell essentially to execute commands, though you get no feedback client-side from the web application: if the command is valid, it executes. An example is the wget command. The page that allows this has been confirmed in firmware as old as 2006."
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "n/a"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://depthsecurity.com/blog/cve-2017-6079-blind-command-injection-in-edgewater-edgemarc-devices",
            "refsource": "MISC",
            "url": "https://depthsecurity.com/blog/cve-2017-6079-blind-command-injection-in-edgewater-edgemarc-devices"
          }
        ]
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:ribboncommunications:edgemarc_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:ribboncommunications:edgemarc_4550:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:ribboncommunications:edgemarc_4552:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:ribboncommunications:edgemarc_4601:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:ribboncommunications:edgemarc_4700:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:ribboncommunications:edgemarc_4750:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:ribboncommunications:edgemarc_4800:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:ribboncommunications:edgemarc_4806:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:ribboncommunications:edgemarc_4808:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:ribboncommunications:edgemarc_7301:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:ribboncommunications:edgemarc_7400:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2017-6079"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "The HTTP web-management application on Edgewater Networks Edgemarc appliances has a hidden page that allows for user-defined commands such as specific iptables routes, etc., to be set. You can use this page as a web shell essentially to execute commands, though you get no feedback client-side from the web application: if the command is valid, it executes. An example is the wget command. The page that allows this has been confirmed in firmware as old as 2006."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "NVD-CWE-noinfo"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://depthsecurity.com/blog/cve-2017-6079-blind-command-injection-in-edgewater-edgemarc-devices",
              "refsource": "MISC",
              "tags": [
                "Exploit",
                "Technical Description",
                "Third Party Advisory"
              ],
              "url": "https://depthsecurity.com/blog/cve-2017-6079-blind-command-injection-in-edgewater-edgemarc-devices"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV2": {
          "acInsufInfo": true,
          "cvssV2": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          "exploitabilityScore": 10.0,
          "impactScore": 10.0,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "severity": "HIGH",
          "userInteractionRequired": false
        },
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 3.9,
          "impactScore": 5.9
        }
      },
      "lastModifiedDate": "2021-09-13T11:20Z",
      "publishedDate": "2017-05-16T17:29Z"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…