FKIE_CVE-2026-76262

Vulnerability from fkie_nvd - Published: 2026-08-19 22:17 - Updated: 2026-08-20 14:25
Summary
In Splunk Enterprise 10.4 versions below 10.4.2, an unauthenticated user could read Prometheus service metrics from the Edge Processor SPL2 Preview sidecar, including service details that expose relevant runtime and build metadata for the sidecar. The vulnerability does not affect Splunk Enterprise versions below 10.4. The information disclosure is possible because the Prometheus metrics endpoint in the Edge Processor SPL2 Preview sidecar lacks authentication, which lets any client that can reach the sidecar retrieve the metrics without credentials. For more information see About Splunk sidecars (https://help.splunk.com/en/splunk-enterprise/administer/admin-manual/10.4/splunk-sidecars/about-splunk-sidecars) in the Splunk documentation.
Impacted products
Vendor Product Version
splunk splunk *

{
  "affected": [
    {
      "affectedData": [
        {
          "product": "Splunk Enterprise",
          "vendor": "Splunk",
          "versions": [
            {
              "lessThan": "10.4.2",
              "status": "affected",
              "version": "10.4",
              "versionType": "custom"
            }
          ]
        }
      ],
      "source": "psirt@cisco.com"
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:splunk:splunk:*:*:*:*:enterprise:*:*:*",
              "matchCriteriaId": "209C1DE6-893D-424D-B103-B64A314AD8DC",
              "versionEndExcluding": "10.4.2",
              "versionStartIncluding": "10.4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "In Splunk Enterprise 10.4 versions below 10.4.2, an unauthenticated user could read Prometheus service metrics from the Edge Processor SPL2 Preview sidecar, including service details that expose relevant runtime and build metadata for the sidecar. The vulnerability does not affect Splunk Enterprise versions below 10.4. The information disclosure is possible because the Prometheus metrics endpoint in the Edge Processor SPL2 Preview sidecar lacks authentication, which lets any client that can reach the sidecar retrieve the metrics without credentials. For more information see About Splunk sidecars (https://help.splunk.com/en/splunk-enterprise/administer/admin-manual/10.4/splunk-sidecars/about-splunk-sidecars) in the Splunk documentation."
    }
  ],
  "id": "CVE-2026-76262",
  "lastModified": "2026-08-20T14:25:19.910",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "psirt@cisco.com",
        "type": "Primary"
      }
    ]
  },
  "published": "2026-08-19T22:17:14.323",
  "references": [
    {
      "source": "psirt@cisco.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://advisory.splunk.com/advisories/SVD-2026-0801"
    }
  ],
  "sourceIdentifier": "psirt@cisco.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-200"
        }
      ],
      "source": "psirt@cisco.com",
      "type": "Primary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Loading…