FKIE_CVE-2026-48136
Vulnerability from fkie_nvd - Published: 2026-05-26 14:16 - Updated: 2026-07-20 20:10
Severity
Summary
When Compliance is enabled on Check Point Multi-Domain Management, an authenticated administrator with read-write access to one Management Domain (CMA) can modify stored metadata associated with Compliance Best Practices in another Management Domain, where the administrator has no access permissions, bypassing Role-Based Access Control (RBAC).
References
Impacted products
| Vendor | Product | Version |
|---|
{
"affected": [
{
"affectedData": [
{
"product": "Quantum Security Management",
"vendor": "checkpoint",
"versions": [
{
"status": "affected",
"version": "R82.10 with Jumbo Hotfix Take 6 or below"
},
{
"status": "affected",
"version": "R82 with Jumbo Hotfix Take 91 or below"
},
{
"status": "affected",
"version": "R81.20 with Jumbo Hotfix Take 127 or below"
},
{
"status": "affected",
"version": "All releases from R81.10 and below"
}
]
}
],
"source": "cve@checkpoint.com"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "When Compliance is enabled on Check Point Multi-Domain Management, an authenticated administrator with read-write access to one Management Domain (CMA) can modify stored metadata associated with Compliance Best Practices in another Management Domain, where the administrator has no access permissions, bypassing Role-Based Access Control (RBAC)."
},
{
"lang": "es",
"value": "Cuando el Cumplimiento est\u00e1 habilitado en Check Point Multi-Domain Management, un administrador autenticado con acceso de lectura y escritura a un Dominio de Gesti\u00f3n (CMA) puede modificar metadatos almacenados asociados con las Mejores Pr\u00e1cticas de Cumplimiento en otro Dominio de Gesti\u00f3n, donde el administrador no tiene permisos de acceso, eludiendo el Control de Acceso Basado en Roles (RBAC)."
}
],
"id": "CVE-2026-48136",
"lastModified": "2026-07-20T20:10:00.110",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 4.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"exploitabilityScore": 0.7,
"impactScore": 3.4,
"source": "cve@checkpoint.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-48136",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-26T18:41:27.298316Z",
"version": "2.0.3"
}
}
]
},
"published": "2026-05-26T14:16:39.130",
"references": [
{
"source": "cve@checkpoint.com",
"url": "https://support.checkpoint.com/results/sk/sk184992"
}
],
"sourceIdentifier": "cve@checkpoint.com",
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-89"
}
],
"source": "cve@checkpoint.com",
"type": "Secondary"
}
]
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
Loading…
Loading…