fkie_cve-2025-14265
Vulnerability from fkie_nvd
Published
2025-12-11 15:15
Modified
2025-12-12 15:18
Severity ?
Summary
In versions of ScreenConnect™ prior to 25.8, server-side validation and integrity checks within the extension subsystem could allow the installation and execution of untrusted or arbitrary extensions by authorized or administrative users. Abuse of this behavior could result in the execution of custom code on the server or unauthorized access to application configuration data. This issue affects only the ScreenConnect server component; host and guest clients are not impacted. ScreenConnect 25.8 introduces enhanced server-side configuration handling and integrity checks to ensure only trusted extensions can be installed.
References
Impacted products
| Vendor | Product | Version |
|---|
{
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In versions of ScreenConnect\u2122 prior to 25.8, server-side validation and integrity checks within the extension subsystem could allow the installation and execution of untrusted or arbitrary extensions by authorized or administrative users. Abuse of this behavior could result in the execution of custom code on the server or unauthorized access to application configuration data. This issue affects only the ScreenConnect server component; host and guest clients are not impacted. ScreenConnect 25.8 introduces enhanced server-side configuration handling and integrity checks to ensure only trusted extensions can be installed."
}
],
"id": "CVE-2025-14265",
"lastModified": "2025-12-12T15:18:13.390",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.3,
"impactScore": 6.0,
"source": "7d616e1a-3288-43b1-a0dd-0a65d3e70a49",
"type": "Secondary"
}
]
},
"published": "2025-12-11T15:15:46.863",
"references": [
{
"source": "7d616e1a-3288-43b1-a0dd-0a65d3e70a49",
"url": "https://www.connectwise.com/company/trust/security-bulletins/screenconnect-2025.8-security-patch"
}
],
"sourceIdentifier": "7d616e1a-3288-43b1-a0dd-0a65d3e70a49",
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-494"
}
],
"source": "7d616e1a-3288-43b1-a0dd-0a65d3e70a49",
"type": "Secondary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…