fkie_cve-2025-0626
Vulnerability from fkie_nvd
Published
2025-01-30 19:15
Modified
2025-01-31 17:15
Severity ?
Summary
Contec Health CMS8000 Patient Monitor sends out remote access requests to a hard-coded IP address, bypassing existing device network settings to do so. This could serve as a backdoor and lead to a malicious actor being able to upload and overwrite files on the device.
References
Impacted products
Vendor | Product | Version |
---|
{ "cveTags": [], "descriptions": [ { "lang": "en", "value": "Contec Health CMS8000 Patient Monitor sends out remote access requests to a hard-coded IP address, bypassing existing device network settings to do so. This could serve as a backdoor and lead to a malicious actor being able to upload and overwrite files on the device." }, { "lang": "es", "value": "El producto afectado env\u00eda solicitudes de acceso remoto a una direcci\u00f3n IP codificada, omitiendo la configuraci\u00f3n de red existente del dispositivo para hacerlo. Esto podr\u00eda funcionar como una puerta trasera y permitir que un actor malintencionado pueda cargar y sobrescribir archivos en el dispositivo." } ], "id": "CVE-2025-0626", "lastModified": "2025-01-31T17:15:16.323", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.6, "impactScore": 5.9, "source": "ics-cert@hq.dhs.gov", "type": "Secondary" } ], "cvssMetricV40": [ { "cvssData": { "attackComplexity": "LOW", "attackRequirements": "PRESENT", "attackVector": "NETWORK", "automatable": "NOT_DEFINED", "availabilityRequirements": "NOT_DEFINED", "baseScore": 7.7, "baseSeverity": "HIGH", "confidentialityRequirements": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirements": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubsequentSystemAvailability": "NOT_DEFINED", "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED", "modifiedSubsequentSystemIntegrity": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnerableSystemAvailability": "NOT_DEFINED", "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED", "modifiedVulnerableSystemIntegrity": "NOT_DEFINED", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "recovery": "NOT_DEFINED", "safety": "NOT_DEFINED", "subsequentSystemAvailability": "NONE", "subsequentSystemConfidentiality": "NONE", "subsequentSystemIntegrity": "NONE", "userInteraction": "PASSIVE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnerabilityResponseEffort": "NOT_DEFINED", "vulnerableSystemAvailability": "HIGH", "vulnerableSystemConfidentiality": "HIGH", "vulnerableSystemIntegrity": "HIGH" }, "source": "ics-cert@hq.dhs.gov", "type": "Secondary" } ] }, "published": "2025-01-30T19:15:14.010", "references": [ { "source": "ics-cert@hq.dhs.gov", "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-030-01" }, { "source": "ics-cert@hq.dhs.gov", "url": "https://www.fda.gov/medical-devices/safety-communications/cybersecurity-vulnerabilities-certain-patient-monitors-contec-and-epsimed-fda-safety-communication" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://www.bleepingcomputer.com/news/security/backdoor-found-in-two-healthcare-patient-monitors-linked-to-ip-in-china/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://www.cisa.gov/resources-tools/resources/contec-cms8000-contains-backdoor" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://www.fda.gov/medical-devices/safety-communications/cybersecurity-vulnerabilities-certain-patient-monitors-contec-and-epsimed-fda-safety-communication" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Awaiting Analysis", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-912" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.