fkie_cve-2023-38485
Vulnerability from fkie_nvd
Published
2023-09-06 18:15
Modified
2024-11-21 08:13
Severity ?
8.0 (High) - CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H
6.4 (Medium) - CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H
6.4 (Medium) - CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H
Summary
Vulnerabilities exist in the BIOS implementation of Aruba 9200 and 9000 Series Controllers and Gateways that could allow an attacker to execute arbitrary code early in the boot sequence. An attacker could exploit this vulnerability to gain access to and change underlying sensitive information in the affected controller leading to complete system compromise.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
arubanetworks | arubaos | * | |
arubanetworks | arubaos | * | |
arubanetworks | arubaos | * | |
arubanetworks | arubaos | * | |
arubanetworks | 9004 | - | |
arubanetworks | 9004-lte | - | |
arubanetworks | 9012 | - | |
arubanetworks | 9240 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:arubanetworks:arubaos:*:*:*:*:*:*:*:*", "matchCriteriaId": "ADB9BE64-9455-46B2-80C8-BD9B88A8F372", "versionEndExcluding": "8.6.0.22", "versionStartIncluding": "8.6.0.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:arubanetworks:arubaos:*:*:*:*:*:*:*:*", "matchCriteriaId": "48293E3F-C6BD-4875-8C7A-67ED41B7C18D", "versionEndExcluding": "8.10.0.7", "versionStartIncluding": "8.10.0.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:arubanetworks:arubaos:*:*:*:*:*:*:*:*", "matchCriteriaId": "A22E7E61-B318-47C8-8C72-498A17031997", "versionEndExcluding": "8.11.1.1", "versionStartIncluding": "8.11.0.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:arubanetworks:arubaos:*:*:*:*:*:*:*:*", "matchCriteriaId": "6418722E-304A-46EF-8D9E-EB42596F0DFC", "versionEndExcluding": "10.4.0.2", "versionStartIncluding": "10.4.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:arubanetworks:9004:-:*:*:*:*:*:*:*", "matchCriteriaId": "CFA13FF5-7C60-48B4-AF46-18A9F19D5D42", "vulnerable": false }, { "criteria": "cpe:2.3:h:arubanetworks:9004-lte:-:*:*:*:*:*:*:*", "matchCriteriaId": "0B1EB3D9-77B5-4DBE-9518-23DD0DA06BC9", "vulnerable": false }, { "criteria": "cpe:2.3:h:arubanetworks:9012:-:*:*:*:*:*:*:*", "matchCriteriaId": "17162DB3-973E-47C6-9157-39A0E94603F2", "vulnerable": false }, { "criteria": "cpe:2.3:h:arubanetworks:9240:-:*:*:*:*:*:*:*", "matchCriteriaId": "A6BF9E0D-630F-40B4-9109-560CA13C981B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Vulnerabilities exist in the BIOS implementation of Aruba 9200 and 9000 Series Controllers and Gateways that could\u00a0allow an attacker to execute arbitrary code early in the boot\u00a0sequence. An attacker could exploit this vulnerability to\u00a0gain access to and change underlying sensitive information\u00a0in the affected controller leading to complete system\u00a0compromise." }, { "lang": "es", "value": "Existen vulnerabilidades en la implementaci\u00f3n del BIOS de los Controladores y Gateways de las Series 9200 y 9000 de Aruba que podr\u00edan permitir a un atacante ejecutar c\u00f3digo arbitrario en las primeras etapas de la secuencia de inicio. Un atacante podr\u00eda aprovechar esta vulnerabilidad para obtener acceso y cambiar informaci\u00f3n sensible subyacente en el controlador afectado, lo que comprometer\u00eda completamente el sistema." } ], "id": "CVE-2023-38485", "lastModified": "2024-11-21T08:13:40.053", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.0, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.3, "impactScore": 6.0, "source": "security-alert@hpe.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.5, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-09-06T18:15:08.480", "references": [ { "source": "security-alert@hpe.com", "tags": [ "Vendor Advisory" ], "url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2023-014.txt" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2023-014.txt" } ], "sourceIdentifier": "security-alert@hpe.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.