fkie_cve-2023-2638
Vulnerability from fkie_nvd
Published
2023-06-13 21:15
Modified
2024-11-21 07:58
Severity ?
5.9 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:N/I:N/A:H
5.0 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:H/A:N
5.0 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:H/A:N
Summary
Rockwell Automation's FactoryTalk System Services does not verify that a backup configuration archive is password protected.
Improper authorization in FTSSBackupRestore.exe may lead to the loading of malicious configuration archives. This vulnerability may allow a local, authenticated non-admin user to craft a malicious backup archive, without password protection, that will be loaded by FactoryTalk System Services as a valid backup when a restore procedure takes places. User interaction is required for this vulnerability to be successfully exploited.
References
▼ | URL | Tags | |
---|---|---|---|
PSIRT@rockwellautomation.com | https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139683 | Permissions Required, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139683 | Permissions Required, Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
rockwellautomation | factorytalk_policy_manager | 6.11.0 | |
rockwellautomation | factorytalk_system_services | 6.11.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_policy_manager:6.11.0:*:*:*:*:*:*:*", "matchCriteriaId": "78D6F03E-E110-4CA7-8883-5CE38FF8E5A0", "vulnerable": true }, { "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_system_services:6.11.0:*:*:*:*:*:*:*", "matchCriteriaId": "46A50229-56B5-4B30-8B4A-6D180D65C2D6", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "\nRockwell Automation\u0027s FactoryTalk System Services does not verify that a backup configuration archive is password protected.\n\n\u00a0\n\nImproper authorization in FTSSBackupRestore.exe may lead to the loading of malicious configuration archives.\u00a0 This vulnerability may allow a local, authenticated non-admin user to craft a malicious backup archive, without password protection, that will be loaded by FactoryTalk System Services as a valid backup when a restore procedure takes places. User interaction is required for this vulnerability to be successfully exploited.\n\n\n" } ], "id": "CVE-2023-2638", "lastModified": "2024-11-21T07:58:58.830", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 5.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 1.5, "impactScore": 4.0, "source": "PSIRT@rockwellautomation.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 5.0, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 1.3, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-06-13T21:15:09.983", "references": [ { "source": "PSIRT@rockwellautomation.com", "tags": [ "Permissions Required", "Vendor Advisory" ], "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139683" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "Vendor Advisory" ], "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139683" } ], "sourceIdentifier": "PSIRT@rockwellautomation.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-287" } ], "source": "PSIRT@rockwellautomation.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-287" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.