fkie_cve-2022-40853
Vulnerability from fkie_nvd
Published
2022-09-23 14:15
Modified
2024-11-21 07:22
Severity ?
Summary
Tenda AC15 router V15.03.05.19 contains a stack overflow via the list parameter at /goform/fast_setting_wifi_set
Impacted products
Vendor Product Version
tendacn ac15_firmware 15.03.05.19
tendacn ac15 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tendacn:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*",
              "matchCriteriaId": "7CF021B8-0BA1-42C9-A2A4-4B4BF18F8D4B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tendacn:ac15:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4EEDF33B-0D03-492A-BCD1-0E6B79F783EF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC15 router V15.03.05.19 contains a stack overflow via the list parameter at /goform/fast_setting_wifi_set"
    },
    {
      "lang": "es",
      "value": "El router Tenda AC15 versi\u00f3n V15.03.05.19, contiene un desbordamiento de pila por medio del par\u00e1metro list en /goform/fast_setting_wifi_set"
    }
  ],
  "id": "CVE-2022-40853",
  "lastModified": "2024-11-21T07:22:09.217",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-09-23T14:15:13.177",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/CPSeek/Router-vuls/blob/main/Tenda/AC15/form_fast_setting_wifi_set.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/CPSeek/Router-vuls/blob/main/Tenda/AC15/form_fast_setting_wifi_set.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.