fkie_cve-2022-40265
Vulnerability from fkie_nvd
Published
2022-11-30 01:15
Modified
2024-11-21 07:21
Summary
Improper Input Validation vulnerability in Mitsubishi Electric Corporation MELSEC iQ-R Series RJ71EN71 Firmware version "65" and prior and Mitsubishi Electric Corporation MELSEC iQ-R Series R04/08/16/32/120ENCPU Network Part Firmware version "65" and prior allows a remote unauthenticated attacker to cause a Denial of Service condition by sending specially crafted packets. A system reset is required for recovery.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rj71en71_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DA6E8D4-26B3-44EA-94EE-D2ABD0E34D5F",
              "versionEndIncluding": "65",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rj71en71:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8BD2CE10-A6DB-4642-8FA8-DD1AFA726EC7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:r04encpu_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "71105F2E-5D80-484B-AE91-964EE6BB00B7",
              "versionEndIncluding": "65",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:r04encpu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C5862905-F77D-4DEE-88A8-59893362936F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:r08encpu_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "882C402E-D0A4-46F9-B983-B86EBCB24E19",
              "versionEndIncluding": "65",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:r08encpu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6B85DAD9-7F5B-4740-94A3-94835D82CE3C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:r16encpu_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "054189D9-B6C3-487F-9FA4-97E2D69C69DD",
              "versionEndIncluding": "65",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:r16encpu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81F7DE17-AA44-4E78-B07B-3D9F641DF445",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:r32encpu_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "417F4AD4-8FF6-4804-A453-0BA857B68BED",
              "versionEndIncluding": "65",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:r32encpu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9546A301-8039-4D42-B1A2-AAF6C3C17203",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:r120encpu_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AF292C53-458C-4DE7-916C-ABD395EBF32B",
              "versionEndIncluding": "65",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:r120encpu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "411C7828-D7C7-4B42-82E3-CAC21C15951C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Improper Input Validation vulnerability in Mitsubishi Electric Corporation MELSEC iQ-R Series RJ71EN71 Firmware version \"65\" and prior and Mitsubishi Electric Corporation MELSEC iQ-R Series R04/08/16/32/120ENCPU Network Part Firmware version \"65\" and prior allows a remote unauthenticated attacker to cause a Denial of Service condition by sending specially crafted packets. A system reset is required for recovery."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de Validaci\u00f3n de Entrada Incorrecta en Mitsubishi Electric Corporation MELSEC iQ-R Series RJ71EN71 Versi\u00f3n de firmware \"65\" y anteriores y Mitsubishi Electric Corporation MELSEC iQ-R Series R04/08/16/32/120ENCPU Network Part Firmware versi\u00f3n \"65\" y anteriores permite una un atacante remoto no autenticado provoque una condici\u00f3n de Denegaci\u00f3n de Servicio mediante el env\u00edo de paquetes especialmente manipulados. Es necesario reiniciar el sistema para la recuperaci\u00f3n."
    }
  ],
  "id": "CVE-2022-40265",
  "lastModified": "2024-11-21T07:21:09.477",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.6,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 4.0,
        "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-11-30T01:15:09.873",
  "references": [
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/vu/JVNVU94702422"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-017_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/vu/JVNVU94702422"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-017_en.pdf"
    }
  ],
  "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ],
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.