fkie_cve-2022-29830
Vulnerability from fkie_nvd
Published
2022-11-25 00:15
Modified
2024-11-21 06:59
Severity ?
9.1 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
9.1 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
9.1 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
Summary
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Motion Control Setting(GX Works3 related software) versions from 1.000A and later allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
mitsubishielectric | gx_works3 | * | |
mitsubishielectric | gx_works3 | * | |
mitsubishielectric | gx_works3 | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*", "matchCriteriaId": "A868567B-2BAA-45AE-AEC9-3AFEF2361297", "versionEndIncluding": "1.011m", "versionStartIncluding": "1.000a", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*", "matchCriteriaId": "56BD062B-0D41-42E2-B9EF-B7FBB514CFF9", "versionEndIncluding": "1.086q", "versionStartIncluding": "1.015r", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*", "matchCriteriaId": "C7C6A654-1B83-4743-8DDE-B8C5AA5C4D2A", "versionStartIncluding": "1.087r", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Motion Control Setting(GX Works3 related software) versions from 1.000A and later allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally." }, { "lang": "es", "value": "El uso de una vulnerabilidad de clave criptogr\u00e1fica codificada en Mitsubishi Electric GX Works3 en las versiones 1.000A hasta 1.095Z y la configuraci\u00f3n de control de movimiento (software relacionado con GX Works3) de 1.000A y posteriores permite a un atacante remoto no autenticado revelar o alterar informaci\u00f3n sensible. Como resultado, los atacantes no autenticados pueden obtener informaci\u00f3n sobre archivos de proyecto de forma ilegal." } ], "id": "CVE-2022-29830", "lastModified": "2024-11-21T06:59:46.313", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.2, "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.2, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-11-25T00:15:10.367", "references": [ { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://jvn.jp/vu/JVNVU97244961/index.html" }, { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05" }, { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://jvn.jp/vu/JVNVU97244961/index.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf" } ], "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-321" } ], "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-798" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.