fkie_cve-2022-27523
Vulnerability from fkie_nvd
Published
2022-04-13 18:15
Modified
2024-11-21 06:55
Summary
A buffer over-read can be exploited in Autodesk TrueView 2022 may lead to an exposure of sensitive information or a crash through using a maliciously crafted DWG file as an Input. This vulnerability in conjunction with other vulnerabilities could lead to code execution in the context of the current process.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:autodesk:dwg_trueview:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3FB6CD03-F783-49F7-A9D2-C97C642E8B29",
              "versionEndExcluding": "2019.1.4",
              "versionStartIncluding": "2019",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:autodesk:dwg_trueview:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E9DF065-576B-46B8-9F64-A16D9CB25398",
              "versionEndExcluding": "2020.1.5",
              "versionStartIncluding": "2020",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:autodesk:dwg_trueview:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "631D559D-B4CB-4D6A-93A7-94C0CA9C232B",
              "versionEndExcluding": "2021.1.2",
              "versionStartIncluding": "2021",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:autodesk:dwg_trueview:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E12F2B7-971F-49EE-BE77-7ADC65368BAD",
              "versionEndExcluding": "2022.1.2",
              "versionStartIncluding": "2022",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A buffer over-read can be exploited in Autodesk TrueView 2022 may lead to an exposure of sensitive information or a crash through using a maliciously crafted DWG file as an Input. This vulnerability in conjunction with other vulnerabilities could lead to code execution in the context of the current process."
    },
    {
      "lang": "es",
      "value": "Una lectura excesiva del b\u00fafer puede ser explotada en Autodesk TrueView versi\u00f3n 2022, puede conllevar una exposici\u00f3n de informaci\u00f3n confidencial o un bloqueo mediante el uso de un archivo DWG maliciosamente dise\u00f1ado como entrada. Esta vulnerabilidad, junto con otras, podr\u00eda conllevar a una ejecuci\u00f3n de c\u00f3digo en el contexto del proceso actual"
    }
  ],
  "id": "CVE-2022-27523",
  "lastModified": "2024-11-21T06:55:52.713",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 4.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.1,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.2,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-04-13T18:15:14.690",
  "references": [
    {
      "source": "psirt@autodesk.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.autodesk.com/trust/security-advisories/adsk-sa-2022-0007"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.autodesk.com/trust/security-advisories/adsk-sa-2022-0007"
    }
  ],
  "sourceIdentifier": "psirt@autodesk.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.