fkie_cve-2022-20765
Vulnerability from fkie_nvd
Published
2022-05-27 14:15
Modified
2024-11-21 06:43
Severity ?
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
Summary
A vulnerability in the web applications of Cisco UCS Director could allow an authenticated, remote attacker to conduct a cross-site scripting attack on an affected system. This vulnerability is due to unsanitized user input. An attacker could exploit this vulnerability by submitting custom JavaScript to affected web applications. A successful exploit could allow the attacker to rewrite web page content, access sensitive information stored in the applications, and alter data by submitting forms.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| cisco | ucs_director | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:cisco:ucs_director:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B365E645-CEA9-4AF6-85E2-0D4464D5D73D",
"versionEndExcluding": "6.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the web applications of Cisco UCS Director could allow an authenticated, remote attacker to conduct a cross-site scripting attack on an affected system. This vulnerability is due to unsanitized user input. An attacker could exploit this vulnerability by submitting custom JavaScript to affected web applications. A successful exploit could allow the attacker to rewrite web page content, access sensitive information stored in the applications, and alter data by submitting forms."
},
{
"lang": "es",
"value": "Una vulnerabilidad en las aplicaciones web de Cisco UCS Director podr\u00eda permitir a un atacante remoto autentificado realizar un ataque de scripting entre sitios en un sistema afectado. Esta vulnerabilidad se debe a una entrada de usuario no saneada. Un atacante podr\u00eda aprovechar esta vulnerabilidad enviando JavaScript personalizado a las aplicaciones web afectadas. Un ataque exitoso podr\u00eda permitir al atacante reescribir el contenido de la p\u00e1gina web, acceder a informaci\u00f3n sensible almacenada en las aplicaciones y alterar los datos mediante el env\u00edo de formularios"
}
],
"id": "CVE-2022-20765",
"lastModified": "2024-11-21T06:43:30.600",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 6.8,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.7,
"impactScore": 2.7,
"source": "psirt@cisco.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.7,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-05-27T14:15:08.620",
"references": [
{
"source": "psirt@cisco.com",
"tags": [
"Vendor Advisory"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-UCS-XSS-uQSME3L7"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-UCS-XSS-uQSME3L7"
}
],
"sourceIdentifier": "psirt@cisco.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-80"
}
],
"source": "psirt@cisco.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…