fkie_cve-2021-45549
Vulnerability from fkie_nvd
Published
2021-12-26 01:15
Modified
2024-11-21 06:32
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects LAX20 before 1.1.6.28, MK62 before 1.1.6.122, MR60 before 1.1.6.122, MS60 before 1.1.6.122, R6400v2 before 1.0.4.118, R6700v3 before 1.0.4.118, R6900P before 1.3.3.140, R7000 before 1.0.11.116, R7000P before 1.3.3.140, R7850 before 1.0.5.68, R7900 before 1.0.4.38, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RS400 before 1.5.1.80, and XR1000 before 1.0.0.58.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:lax20_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "48709EA4-81F3-4CF1-B9A8-5379309914B0",
              "versionEndExcluding": "1.1.6.28",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:lax20:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "491CEB8D-22F3-4F86-96F0-03C5C58BA295",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:mk62_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0A6768BE-C869-4CC5-B683-08B8E4DDD683",
              "versionEndExcluding": "1.1.6.122",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:mk62:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "69A79475-37BE-47BD-A629-DCEF22500B0B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4F6E7187-B191-473D-9E9D-0990447AB8C6",
              "versionEndExcluding": "1.1.6.122",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "65BB3ECD-2F0B-4625-A1DB-F6CEFC46E277",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "476B2ED6-D7C9-4B84-BCD0-9C98B80A5F53",
              "versionEndExcluding": "1.1.6.122",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F003F064-591C-4D7C-9EC4-D0E553BC6683",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "87F3EAAB-C4C2-47BA-B87A-3CFF0C52EF21",
              "versionEndExcluding": "1.0.4.118",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "57A029C8-4DE3-4393-BD61-E9562C4E17D8",
              "versionEndExcluding": "1.0.4.118",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r6700:v3:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A09A9E8-8C77-4EDB-9483-B3C540EF083A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "94795476-184B-4E7D-9D8B-ECB45609108E",
              "versionEndExcluding": "1.3.3.140",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D9F1DAD0-F8B8-48D5-B571-C55636B274C3",
              "versionEndExcluding": "1.0.11.116",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C3A7E8BF-8CC3-4806-89F5-FBE01A36A1FD",
              "versionEndExcluding": "1.3.3.140",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EF7A1DF8-E9A0-4312-AC37-DEB46E37EE50",
              "versionEndExcluding": "1.0.5.68",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DAF94D73-B6D0-4334-9A41-83AA92B7C6DF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "96390A31-03B8-477B-8710-F797CB44E741",
              "versionEndExcluding": "1.0.4.38",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA344C08-94F1-47F8-9607-3D854B890E19",
              "versionEndExcluding": "1.4.2.84",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "33B2293C-09AD-4B5A-B2A0-923E2B9923AA",
              "versionEndExcluding": "1.4.2.84",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "091CEDB5-0069-4253-86D8-B9FE17CB9F24",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D10E41DC-982F-444A-9A4D-82EC2BA64199",
              "versionEndExcluding": "1.0.4.68",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4905D866-2326-487F-AAA5-96ABA0DBD56E",
              "versionEndExcluding": "1.4.2.84",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2268D5EF-E7FA-4112-A468-507417E18FFF",
              "versionEndExcluding": "1.0.3.96",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B624B4D3-BCF4-4F95-B401-A88BEC3145A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "31289572-2197-4A38-8353-CA4AAD491160",
              "versionEndExcluding": "1.0.3.96",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7038703C-C79D-4DD4-8B16-E1A5FC6694C0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6334DE4D-E78B-4582-9C6F-6123DA5192C7",
              "versionEndExcluding": "1.0.4.120",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax35_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "255508E6-628A-4C83-BA39-90C9D05197B7",
              "versionEndExcluding": "1.0.3.96",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax35:v2:*:*:*:*:*:*:*",
              "matchCriteriaId": "972BB714-8869-42C6-95F6-2C15AFA65716",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax40_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "68163CF2-4781-4B87-8E39-62B4DF82A44A",
              "versionEndExcluding": "1.0.3.96",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax40:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "13D54346-4B03-4296-B050-04EB8CFCA732",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax43_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8AC89EAA-344C-438E-A5A5-2C34CF699743",
              "versionEndExcluding": "1.0.3.96",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax43:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "178BB386-F66C-4CE8-9283-37D22B304691",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0706367A-3F60-4564-8689-E0A46DDC31C2",
              "versionEndExcluding": "1.0.3.96",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B08BD69-CDCC-4CEB-B887-4E47D2B45D26",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "679C4EC5-D17E-469B-A28F-BF5E231CED3D",
              "versionEndExcluding": "1.0.3.96",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C430976E-24C0-4EA7-BF54-F9C188AB9C01",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BDF9F3BA-4239-4F4D-A65E-A6752A5420F6",
              "versionEndExcluding": "1.0.4.120",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "334BB384-5C29-4D24-9F82-B8EE8D0CA8BF",
              "versionEndExcluding": "1.0.4.120",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "95AF0FA9-F2C5-4D84-BF37-AA8CB6EC3C4A",
              "versionEndExcluding": "1.5.1.80",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rs400:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2700644E-0940-4D05-B3CA-904D91739E58",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:xr1000_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F615F516-29EF-4C15-9E18-C5D4F6291A38",
              "versionEndExcluding": "1.0.0.58",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:xr1000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4FD4ED11-4130-47DA-8A9D-55B8F6E3E213",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects LAX20 before 1.1.6.28, MK62 before 1.1.6.122, MR60 before 1.1.6.122, MS60 before 1.1.6.122, R6400v2 before 1.0.4.118, R6700v3 before 1.0.4.118, R6900P before 1.3.3.140, R7000 before 1.0.11.116, R7000P before 1.3.3.140, R7850 before 1.0.5.68, R7900 before 1.0.4.38, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RS400 before 1.5.1.80, and XR1000 before 1.0.0.58."
    },
    {
      "lang": "es",
      "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a LAX20 versiones anteriores a 1.1.6.28, MK62 versiones anteriores a 1.1.6.122, MR60 versiones anteriores a 1.1.6.122, MS60 versiones anteriores a 1.1.6.122, R6400v2 versiones anteriores a 1.0.4.118, R6700v3 versiones anteriores a 1.0.4. 118, R6900P versiones anteriores a 1.3.3.140, R7000 versiones anteriores a 1.0.11.116, R7000P versiones anteriores a 1.3.3.140, R7850 versiones anteriores a 1.0.5.68, R7900 versiones anteriores a 1.0.4.38, R7900P versiones anteriores a 1.4.2.84, R7960P versiones anteriores a 1.4.2. 84, R8000 versiones anteriores a 1.0.4.68, R8000P versiones anteriores a 1.4.2.84, RAX15 versiones anteriores a 1.0.3.96, RAX20 versiones anteriores a 1.0.3.96, RAX200 versiones anteriores a 1.0.4.120, RAX35v2 versiones anteriores a 1.0.3.96, RAX40v2 versiones anteriores a 1.0.3. 96, RAX43 versiones anteriores a 1.0.3.96, RAX45 versiones anteriores a 1.0.3.96, RAX50 versiones anteriores a 1.0.3.96, RAX75 versiones anteriores a 1.0.4.120, RAX80 versiones anteriores a 1.0.4.120, RS400 versiones anteriores a 1.5.1.80 y XR1000 versiones anteriores a 1.0.0.58"
    }
  ],
  "id": "CVE-2021-45549",
  "lastModified": "2024-11-21T06:32:29.353",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "ADJACENT_NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.2,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 5.1,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.4,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.7,
        "impactScore": 6.0,
        "source": "cve@mitre.org",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-26T01:15:15.320",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000064513/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0517"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000064513/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0517"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.