fkie_cve-2021-27041
Vulnerability from fkie_nvd
Published
2021-06-25 13:15
Modified
2024-11-21 05:57
Severity ?
Summary
A maliciously crafted DWG file can be used to write beyond the allocated buffer while parsing DWG files. This vulnerability can be exploited to execute arbitrary code
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:autodesk:advance_steel:*:*:*:*:*:*:*:*", "matchCriteriaId": "DDC0E547-C366-4A0E-95DE-EC420492E698", "versionEndExcluding": "2019.1.3", "versionStartIncluding": "2019", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:advance_steel:*:*:*:*:*:*:*:*", "matchCriteriaId": "B8319413-E093-4931-B2DB-A46522DF93C9", "versionEndExcluding": "2020.1.4", "versionStartIncluding": "2020", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:advance_steel:*:*:*:*:*:*:*:*", "matchCriteriaId": "0B350B87-23EC-44F8-9A5F-9AC815E15BD9", "versionEndExcluding": "2021.1.1", "versionStartIncluding": "2021", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:advance_steel:*:*:*:*:*:*:*:*", "matchCriteriaId": "CAE14E69-8BCB-4E00-8BAB-CB7F1688DC27", "versionEndExcluding": "2022.0.1", "versionStartIncluding": "2022", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:autocad:*:*:*:*:*:*:*:*", "matchCriteriaId": "A084A960-35D8-4B9C-87DE-0213CA40CAD8", "versionEndExcluding": "2019.1.3", "versionStartIncluding": "2019", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:autocad:*:*:*:*:*:*:*:*", "matchCriteriaId": "20EE0BDC-3A97-4CD4-A232-922F8D613856", "versionEndExcluding": "2020.1.4", "versionStartIncluding": "2020", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:autocad:*:*:*:*:*:*:*:*", "matchCriteriaId": "5FDD2042-5313-4658-AA4E-109684E91C43", "versionEndExcluding": "2021.1.1", "versionStartIncluding": "2021", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:autocad:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE031BD1-9F02-44C2-865E-2011511B36F5", "versionEndExcluding": "2022.0.1", "versionStartIncluding": "2022", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:*", "matchCriteriaId": "0A51CDDA-0D83-4331-9AB6-F6ED076157F6", "versionEndExcluding": "2019.1.3", "versionStartIncluding": "2019", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:*", "matchCriteriaId": "143F8B16-E253-477E-9875-94928BE5596B", "versionEndExcluding": "2020.1.4", "versionStartIncluding": "2020", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:*", "matchCriteriaId": "607A4804-A286-4237-82C3-8BE98662AE20", "versionEndExcluding": "2021.1.1", "versionStartIncluding": "2021", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:*", "matchCriteriaId": "967B286E-5E73-47E3-BC2F-951E26720370", "versionEndIncluding": "2022.0.1", "versionStartIncluding": "2022", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:*", "matchCriteriaId": "64C50E3E-8EFA-4B0D-B284-CF8FE4129866", "versionEndExcluding": "2019.1.3", "versionStartIncluding": "2019", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:*", "matchCriteriaId": "CBD4F808-CA46-4A8E-82DD-6D1A82DDF91C", "versionEndExcluding": "2020.1.4", "versionStartIncluding": "2020", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:*", "matchCriteriaId": "DFD09E68-2C34-4E76-9B67-868FA6E825A6", "versionEndExcluding": "2021.1.1", "versionStartIncluding": "2021", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:*", "matchCriteriaId": "08BC587D-E4C7-4758-8AF5-1970892C35C8", "versionEndExcluding": "2022.0.1", "versionStartIncluding": "2022", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:autocad_lt:*:*:*:*:*:*:*:*", "matchCriteriaId": "282A07AC-8D43-4580-8D2E-8E30370049F3", "versionEndExcluding": "2019.1.3", "versionStartIncluding": "2019", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:autocad_lt:*:*:*:*:*:*:*:*", "matchCriteriaId": "E37E4967-AC88-42D6-98C2-1BA63F20BD5C", "versionEndExcluding": "2020.1.4", "versionStartIncluding": "2020", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:autocad_lt:*:*:*:*:*:*:*:*", "matchCriteriaId": "49512EB3-DE17-45FF-AB90-2966462A9C3C", "versionEndExcluding": "2021.1.1", "versionStartIncluding": "2021", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:autocad_lt:*:*:*:*:*:*:*:*", "matchCriteriaId": "01A870BA-E78E-4975-BF6D-7D410BE8CD6C", "versionEndExcluding": "2022.0.1", "versionStartIncluding": "2022", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:autocad_map_3d:*:*:*:*:*:*:*:*", "matchCriteriaId": "6EF85630-3DDC-4026-AC5A-F1B197F98C9E", "versionEndExcluding": "2019.1.3", "versionStartIncluding": "2019", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:autocad_map_3d:*:*:*:*:*:*:*:*", "matchCriteriaId": "F5309100-B3E9-4144-AEA3-B9030E93FD78", "versionEndExcluding": "2020.1.4", "versionStartIncluding": "2020", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:autocad_map_3d:*:*:*:*:*:*:*:*", "matchCriteriaId": "954682D1-2E7A-4EAB-B4B8-43E2038EB7C7", "versionEndExcluding": "2021.1.1", "versionStartIncluding": "2021", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:autocad_map_3d:*:*:*:*:*:*:*:*", "matchCriteriaId": "1016D7F3-2780-4412-A7AA-361B44A8632E", "versionEndExcluding": "2022.0.1", "versionStartIncluding": "2022", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:*", "matchCriteriaId": "A3D0B0D7-FC6F-43D8-85AA-AC0BD464E5A1", "versionEndExcluding": "2019.1.3", "versionStartIncluding": "2019", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:*", "matchCriteriaId": "AF6DF983-6772-45D4-A82A-EE1BB2EEFD4F", "versionEndExcluding": "2020.1.4", "versionStartIncluding": "2020", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:*", "matchCriteriaId": "F7ABD866-E08B-42F3-A19A-5574563AA540", "versionEndExcluding": "2021.1.1", "versionStartIncluding": "2021", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:*", "matchCriteriaId": "6716F29E-FBA2-4178-A8AE-269D9CC5AC59", "versionEndExcluding": "2022.0.1", "versionStartIncluding": "2022", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:*", "matchCriteriaId": "372905FF-2C9B-4366-BE56-36CACDA63BCD", "versionEndExcluding": "2019.1.3", "versionStartIncluding": "2019", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:*", "matchCriteriaId": "D2F1DCEB-7ABB-4109-943A-E2DEFB17D330", "versionEndExcluding": "2020.1.4", "versionStartIncluding": "2020", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA49E2B8-CBF5-4F6E-A832-D1FDB597FADE", "versionEndExcluding": "2021.1.1", "versionStartIncluding": "2021", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:*", "matchCriteriaId": "8CF7601F-D6A3-4CD6-961D-B8B1B82E29CE", "versionEndExcluding": "2022.0.1", "versionStartIncluding": "2022", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F285B8D-585C-4C23-98FA-E09DE53C8247", "versionEndExcluding": "2019.1.3", "versionStartIncluding": "2019", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:*", "matchCriteriaId": "A10D9CEE-D92D-470D-928F-8F90243618EE", "versionEndExcluding": "2020.1.4", "versionStartIncluding": "2020", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:*", "matchCriteriaId": "0199953B-BCAC-405E-BDC6-951BEAE01570", "versionEndExcluding": "2021.1.1", "versionStartIncluding": "2021", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:*", "matchCriteriaId": "FBDFDF50-5230-41F1-B380-AD3EC4B53DB7", "versionEndExcluding": "2022.0.1", "versionStartIncluding": "2022", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:civil_3d:*:*:*:*:*:*:*:*", "matchCriteriaId": "F6A3326B-382B-4137-B0E7-0D54E825B717", "versionEndExcluding": "2019.1.3", "versionStartIncluding": "2019", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:civil_3d:*:*:*:*:*:*:*:*", "matchCriteriaId": "48F67A57-7528-406B-9BF1-6A963F732564", "versionEndExcluding": "2020.1.4", "versionStartIncluding": "2020", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:civil_3d:*:*:*:*:*:*:*:*", "matchCriteriaId": "825FC323-CAE7-4B39-85AD-966980D30D89", "versionEndExcluding": "2021.1.1", "versionStartIncluding": "2021", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:civil_3d:*:*:*:*:*:*:*:*", "matchCriteriaId": "F430EA73-2B9F-42D9-9005-42F439ABF63C", "versionEndExcluding": "2022.0.1", "versionStartIncluding": "2022", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:design_review:2018:-:*:*:*:*:*:*", "matchCriteriaId": "213232B9-A40B-436D-A66A-B65C49D59BE6", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:design_review:2018:hotfix:*:*:*:*:*:*", "matchCriteriaId": "2D0CF4DC-ACA5-41D0-B28E-CEB5D2C96F71", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:design_review:2018:hotfix2:*:*:*:*:*:*", "matchCriteriaId": "84ED1789-A17F-48F7-A152-09D2A5C59254", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:design_review:2018:hotfix3:*:*:*:*:*:*", "matchCriteriaId": "74819924-EB63-4BBF-9986-FEF6100EEE15", "vulnerable": true }, { "criteria": "cpe:2.3:a:autodesk:design_review:2018:hotfix4:*:*:*:*:*:*", "matchCriteriaId": "100922EF-C773-4798-B352-B16FCAD48F36", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:iconics:genesis64:*:*:*:*:*:*:*:*", "matchCriteriaId": "EC66E916-D8A4-475B-A7E3-4E2FEF46A7B9", "versionEndIncluding": "10.97", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:mitsubishielectric:mc_works64:*:*:*:*:*:*:*:*", "matchCriteriaId": "AAE9E820-2348-4895-9F7D-96071747109D", "versionEndIncluding": "4.04e", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A maliciously crafted DWG file can be used to write beyond the allocated buffer while parsing DWG files. This vulnerability can be exploited to execute arbitrary code" }, { "lang": "es", "value": "Un archivo DWG malicioso puede ser utilizado para escribir m\u00e1s all\u00e1 del buffer asignado mientras se analizan los archivos DWG. Esta vulnerabilidad puede ser explotada para ejecutar c\u00f3digo arbitrario" } ], "id": "CVE-2021-27041", "lastModified": "2024-11-21T05:57:14.057", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-06-25T13:15:08.217", "references": [ { "source": "psirt@autodesk.com", "tags": [ "Vendor Advisory" ], "url": "https://www.autodesk.com/trust/security-advisories/adsk-sa-2022-0007" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.autodesk.com/trust/security-advisories/adsk-sa-2022-0007" } ], "sourceIdentifier": "psirt@autodesk.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.