fkie_cve-2021-25137
Vulnerability from fkie_nvd
Published
2021-01-29 19:15
Modified
2024-11-21 05:54
Severity ?
Summary
The Baseboard Management Controller(BMC) in HPE Cloudline CL5800 Gen9 Server; HPE Cloudline CL5200 Gen9 Server; HPE Cloudline CL4100 Gen10 Server; HPE Cloudline CL3100 Gen10 Server; HPE Cloudline CL5800 Gen10 Server BMC firmware has a local buffer overlfow in spx_restservice startflash_func function.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
hpe | cloudline_cl3100_gen10_server_firmware | 1.08.0.0 | |
hpe | cloudline_cl3100_gen10_server_firmware | 1.10.0.0 | |
hpe | cloudline_cl3100_gen10_server | - | |
hpe | cloudline_cl4100_gen10_server_firmware | 1.08.0.0 | |
hpe | cloudline_cl4100_gen10_server_firmware | 1.10.0.0 | |
hpe | cloudline_cl4100_gen10_server | - | |
hpe | cloudline_cl5200_gen9_server_firmware | 1.07.0.0 | |
hpe | cloudline_cl5200_gen9_server | - | |
hpe | cloudline_cl5800_gen10_server_firmware | 1.08.0.0 | |
hpe | cloudline_cl5800_gen10_server | - | |
hpe | cloudline_cl5800_gen9_server_firmware | 1.09.0.0 | |
hpe | cloudline_cl5800_gen9_server | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:hpe:cloudline_cl3100_gen10_server_firmware:1.08.0.0:*:*:*:*:*:*:*", "matchCriteriaId": "662D4441-34A1-4BBF-9EB4-1FC94D1736F1", "vulnerable": true }, { "criteria": "cpe:2.3:o:hpe:cloudline_cl3100_gen10_server_firmware:1.10.0.0:*:*:*:*:*:*:*", "matchCriteriaId": "9D130324-445C-47F1-993E-387399A9AEB6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:hpe:cloudline_cl3100_gen10_server:-:*:*:*:*:*:*:*", "matchCriteriaId": "BCB48BA1-2048-42F4-A195-F910B875196B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:hpe:cloudline_cl4100_gen10_server_firmware:1.08.0.0:*:*:*:*:*:*:*", "matchCriteriaId": "81ACE979-5E08-40CC-A33B-F602FE14CCE4", "vulnerable": true }, { "criteria": "cpe:2.3:o:hpe:cloudline_cl4100_gen10_server_firmware:1.10.0.0:*:*:*:*:*:*:*", "matchCriteriaId": "6C211F7F-A1E9-4851-A26F-B83B57C32133", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:hpe:cloudline_cl4100_gen10_server:-:*:*:*:*:*:*:*", "matchCriteriaId": "5FD84248-F258-4F3A-BD05-E474FE7D6697", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:hpe:cloudline_cl5200_gen9_server_firmware:1.07.0.0:*:*:*:*:*:*:*", "matchCriteriaId": "190FEC40-B9DA-48D6-8DB2-9D524A8FD088", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:hpe:cloudline_cl5200_gen9_server:-:*:*:*:*:*:*:*", "matchCriteriaId": "D8BB0745-54DA-4792-B570-AE037E7C38D5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:hpe:cloudline_cl5800_gen10_server_firmware:1.08.0.0:*:*:*:*:*:*:*", "matchCriteriaId": "E0D91102-123F-4009-AB13-BE897220BACE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:hpe:cloudline_cl5800_gen10_server:-:*:*:*:*:*:*:*", "matchCriteriaId": "5410F9D6-9040-4155-A499-30B1814BF36B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:hpe:cloudline_cl5800_gen9_server_firmware:1.09.0.0:*:*:*:*:*:*:*", "matchCriteriaId": "4C359672-5A70-4D99-972D-9A84A518B8AB", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:hpe:cloudline_cl5800_gen9_server:-:*:*:*:*:*:*:*", "matchCriteriaId": "149886B8-4820-4D7F-ACA6-68FE3DE32D18", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "The Baseboard Management Controller(BMC) in HPE Cloudline CL5800 Gen9 Server; HPE Cloudline CL5200 Gen9 Server; HPE Cloudline CL4100 Gen10 Server; HPE Cloudline CL3100 Gen10 Server; HPE Cloudline CL5800 Gen10 Server BMC firmware has a local buffer overlfow in spx_restservice startflash_func function." }, { "lang": "es", "value": "El Baseboard Management Controller (BMC) en HPE Cloudline CL5800 Gen9 Server; HPE Cloudline CL5200 Gen9 Server; HPE Cloudline CL4100 Gen10 Server; HPE Cloudline CL3100 Gen10 Server; HPE Cloudline CL5800 Gen10 Server, el firmware de BMC presenta un desbordamiento del b\u00fafer local en la funci\u00f3n startflash_func de spx_restservice" } ], "id": "CVE-2021-25137", "lastModified": "2024-11-21T05:54:25.520", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-01-29T19:15:14.287", "references": [ { "source": "security-alert@hpe.com", "tags": [ "Vendor Advisory" ], "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04073en_us" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04073en_us" } ], "sourceIdentifier": "security-alert@hpe.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.