fkie_cve-2021-21913
Vulnerability from fkie_nvd
Published
2021-09-23 15:15
Modified
2024-11-21 05:49
Severity ?
Summary
An information disclosure vulnerability exists in the WiFi Smart Mesh functionality of D-LINK DIR-3040 1.13B03. A specially-crafted network request can lead to command execution. An attacker can connect to the MQTT service to trigger this vulnerability.
References
▼ | URL | Tags | |
---|---|---|---|
talos-cna@cisco.com | https://talosintelligence.com/vulnerability_reports/TALOS-2021-1361 | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://talosintelligence.com/vulnerability_reports/TALOS-2021-1361 | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
dlink | dir-3040_firmware | 1.13b03 | |
dlink | dir-3040 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-3040_firmware:1.13b03:*:*:*:*:*:*:*", "matchCriteriaId": "8495556A-FE73-4D22-A3F1-367D0D143DBD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-3040:-:*:*:*:*:*:*:*", "matchCriteriaId": "A4EDA686-7BB6-49CB-8370-E0E5F53914A8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An information disclosure vulnerability exists in the WiFi Smart Mesh functionality of D-LINK DIR-3040 1.13B03. A specially-crafted network request can lead to command execution. An attacker can connect to the MQTT service to trigger this vulnerability." }, { "lang": "es", "value": "Se presenta una vulnerabilidad de divulgaci\u00f3n de informaci\u00f3n en la funcionalidad WiFi Smart Mesh de D-LINK DIR-3040 versi\u00f3n 1.13B03. Una petici\u00f3n de red especialmente dise\u00f1ada puede conllevar a una ejecuci\u00f3n de un comando. Un atacante puede conectarse al servicio MQTT para desencadenar esta vulnerabilidad" } ], "id": "CVE-2021-21913", "lastModified": "2024-11-21T05:49:13.897", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 10.0, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 6.0, "source": "talos-cna@cisco.com", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-09-23T15:15:07.527", "references": [ { "source": "talos-cna@cisco.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1361" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1361" } ], "sourceIdentifier": "talos-cna@cisco.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-798" } ], "source": "talos-cna@cisco.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-798" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.