Summary
Incorrect Privilege Assignment vulnerability in Eaton's Intelligent Power Manager (IPM) v1.67 & prior allow non-admin users to upload the system configuration files by sending specially crafted requests. This can result in non-admin users manipulating the system configurations via uploading the configurations with incorrect parameters.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
eaton | intelligent_power_manager | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:eaton:intelligent_power_manager:*:*:*:*:*:*:*:*", "matchCriteriaId": "E94000EF-A58E-4E02-93B2-2FA18D6DD0E6", "versionEndIncluding": "1.67", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Incorrect Privilege Assignment vulnerability in Eaton\u0027s Intelligent Power Manager (IPM) v1.67 \u0026 prior allow non-admin users to upload the system configuration files by sending specially crafted requests. This can result in non-admin users manipulating the system configurations via uploading the configurations with incorrect parameters." }, { "lang": "es", "value": "Una vulnerabilidad de Asignaci\u00f3n de Privilegios Incorrecta en Eaton Intelligent Power Manager (IPM) versiones v1.67 y anteriores, permite a los usuarios no administradores cargar los archivos de configuraci\u00f3n del sistema mediante el env\u00edo de peticiones especialmente dise\u00f1adas. Esto puede resultar en que usuarios no administradores manipulen las configuraciones del sistema al cargar las configuraciones con par\u00e1metros incorrectos." } ], "id": "CVE-2020-6652", "lastModified": "2024-11-21T05:36:06.013", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 4.6, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "CybersecurityCOE@eaton.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-05-07T16:15:11.390", "references": [ { "source": "CybersecurityCOE@eaton.com", "tags": [ "Vendor Advisory" ], "url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/eaton-vulnerability-advisory-intelligent-power-manager-v1-1.pdf" }, { "source": "CybersecurityCOE@eaton.com", "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-650/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/eaton-vulnerability-advisory-intelligent-power-manager-v1-1.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-650/" } ], "sourceIdentifier": "CybersecurityCOE@eaton.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-266" } ], "source": "CybersecurityCOE@eaton.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-269" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.