fkie_cve-2020-3318
Vulnerability from fkie_nvd
Published
2020-05-06 17:15
Modified
2024-11-26 16:09
Severity ?
Summary
Multiple vulnerabilities in Cisco Firepower Management Center (FMC) Software and Cisco Firepower User Agent Software could allow an attacker to access a sensitive part of an affected system with a high-privileged account. For more information about these vulnerabilities, see the Details section of this advisory.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| cisco | secure_firewall_management_center | 2.0.3 | |
| cisco | secure_firewall_management_center | 2.1.0 | |
| cisco | secure_firewall_management_center | 2.1.1 | |
| cisco | secure_firewall_management_center | 2.2.0 | |
| cisco | secure_firewall_management_center | 2.3.0 | |
| cisco | secure_firewall_management_center | 5.0.0 | |
| cisco | secure_firewall_management_center | 6.0.0 | |
| cisco | secure_firewall_management_center | 6.1.0 | |
| cisco | secure_firewall_management_center | 6.2.0 | |
| cisco | secure_firewall_management_center | 6.2.3 | |
| cisco | secure_firewall_management_center | 6.3.0 | |
| cisco | secure_firewall_management_center | 6.4.0 | |
| cisco | secure_firewall_management_center | 6.5.0 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:2.0.3:*:*:*:*:*:*:*",
"matchCriteriaId": "7FF8F9FC-9A18-4AC5-A90A-F7103CE562B7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:2.1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "9ECF16EC-BF5F-4547-A7C4-A91801DE32F6",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:2.1.1:*:*:*:*:*:*:*",
"matchCriteriaId": "4DE78FEC-FB06-4119-80E1-56F3877A9626",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:2.2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "0F22637F-C6C3-4A71-BF8A-0F1054EBED27",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:2.3.0:*:*:*:*:*:*:*",
"matchCriteriaId": "AEBB8B45-E008-4461-AABD-D8D260CAC3F0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:5.0.0:*:*:*:*:*:*:*",
"matchCriteriaId": "9FB9CA77-4857-416A-8624-7D88B1DCC84C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:6.0.0:*:*:*:*:*:*:*",
"matchCriteriaId": "036E4035-E8E2-4964-A6F4-7292E1804E91",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:6.1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "6614ED6C-E77E-4C0D-AA96-0BEE84BE2F94",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:6.2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "EEEB9A40-0062-406D-B56D-3163CBBE08D4",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:6.2.3:*:*:*:*:*:*:*",
"matchCriteriaId": "6175407A-207E-4844-B150-EA0129C4CBBD",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:6.3.0:*:*:*:*:*:*:*",
"matchCriteriaId": "134B9AFF-6FFF-4082-80CB-AD2ACBF832F9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:6.4.0:*:*:*:*:*:*:*",
"matchCriteriaId": "52651664-CA65-4812-8226-E104E1BE7864",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:6.5.0:*:*:*:*:*:*:*",
"matchCriteriaId": "60881FF9-5ACA-4097-8177-56B3DE192B2E",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Multiple vulnerabilities in Cisco Firepower Management Center (FMC) Software and Cisco Firepower User Agent Software could allow an attacker to access a sensitive part of an affected system with a high-privileged account. For more information about these vulnerabilities, see the Details section of this advisory."
},
{
"lang": "es",
"value": "M\u00faltiples vulnerabilidades en el Cisco Firepower Management Center (FMC) Software y Cisco Firepower User Agent Software, podr\u00edan permitir a un atacante acceder a una parte confidencial de un sistema afectado con una cuenta muy privilegiada. Para m\u00e1s informaci\u00f3n sobre estas vulnerabilidades, consulte la secci\u00f3n Detalles de este aviso."
}
],
"id": "CVE-2020-3318",
"lastModified": "2024-11-26T16:09:02.407",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.2,
"impactScore": 5.9,
"source": "psirt@cisco.com",
"type": "Secondary"
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-05-06T17:15:13.887",
"references": [
{
"source": "psirt@cisco.com",
"tags": [
"Vendor Advisory"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmcua-statcred-weeCcZct"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmcua-statcred-weeCcZct"
}
],
"sourceIdentifier": "psirt@cisco.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-798"
}
],
"source": "psirt@cisco.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-798"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…