fkie_cve-2020-29031
Vulnerability from fkie_nvd
Published
2021-02-15 16:15
Modified
2024-11-21 05:23
Severity ?
7.1 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N
8.1 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N
8.1 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N
Summary
An Insecure Direct Object Reference vulnerability exists in the web UI of the GateManager which allows an authenticated attacker to reset the password of any user in its domain or any sub-domain, via escalation of privileges. This issue affects all GateManager versions prior to 9.2c
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:secomea:gatemanager_8250_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "961FED65-FA19-40DA-8DEB-5950D67FE5AA", "versionEndExcluding": "9.2c", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:secomea:gatemanager_8250:-:*:*:*:*:*:*:*", "matchCriteriaId": "5089C475-2013-4DF6-AD1E-12F576ACAE8E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:secomea:gatemanager_4250_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E1FB8107-437D-4900-BA64-2928E33A13C2", "versionEndExcluding": "9.0i", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:secomea:gatemanager_4250:-:*:*:*:*:*:*:*", "matchCriteriaId": "0DB6136A-5440-4980-940D-CD178DC219B8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:secomea:gatemanager_4260_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DE7495A8-DCDD-4CE8-9D32-85BC9C5A4288", "versionEndExcluding": "9.0i", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:secomea:gatemanager_4260:-:*:*:*:*:*:*:*", "matchCriteriaId": "9B546E62-81BB-4ED8-87C9-41BD79484AD0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:secomea:gatemanager_9250_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1B1EB5FA-451C-45E2-8D5F-7E88995D06BF", "versionEndExcluding": "9.0i", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:secomea:gatemanager_9250:-:*:*:*:*:*:*:*", "matchCriteriaId": "68DE2092-2EA1-4D49-84EB-20BE2CD7B113", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An Insecure Direct Object Reference vulnerability exists in the web UI of the GateManager which allows an authenticated attacker to reset the password of any user in its domain or any sub-domain, via escalation of privileges. This issue affects all GateManager versions prior to 9.2c" }, { "lang": "es", "value": "Se presenta una vulnerabilidad de Referencia Directa a Objetos No Segura en la Interfaz de Usuario Web de GateManager que permite a un atacante autenticado restablecer la contrase\u00f1a de cualquier usuario en su dominio o subdominio, por medio de una escalada de privilegios.\u0026#xa0;Este problema afecta a todas las versiones de GateManager anteriores a 9.2c" } ], "id": "CVE-2020-29031", "lastModified": "2024-11-21T05:23:33.977", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 5.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 4.2, "source": "VulnerabilityReporting@secomea.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.2, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-02-15T16:15:14.857", "references": [ { "source": "VulnerabilityReporting@secomea.com", "tags": [ "Vendor Advisory" ], "url": "https://www.secomea.com/support/cybersecurity-advisory/#2920" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.secomea.com/support/cybersecurity-advisory/#2920" } ], "sourceIdentifier": "VulnerabilityReporting@secomea.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-280" } ], "source": "VulnerabilityReporting@secomea.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-269" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.