fkie_cve-2020-26079
Vulnerability from fkie_nvd
Published
2020-11-18 18:15
Modified
2024-11-21 05:19
Severity ?
Summary
A vulnerability in the web UI of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to obtain hashes of user passwords on an affected device. The vulnerability is due to insufficient protection of user credentials. An attacker could exploit this vulnerability by logging in as an administrative user and crafting a call for user information. A successful exploit could allow the attacker to obtain hashes of user passwords on an affected device.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
cisco | iot_field_network_director | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:cisco:iot_field_network_director:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D507A4F-4079-4B68-997E-88901E063348", "versionEndExcluding": "4.6.1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability in the web UI of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to obtain hashes of user passwords on an affected device. The vulnerability is due to insufficient protection of user credentials. An attacker could exploit this vulnerability by logging in as an administrative user and crafting a call for user information. A successful exploit could allow the attacker to obtain hashes of user passwords on an affected device." }, { "lang": "es", "value": "Una vulnerabilidad en la interfaz de usuario web de Cisco IoT Field Network Director (FND), podr\u00eda permitir a un atacante remoto autenticado obtener el hash de contrase\u00f1as de los usuarios en un dispositivo afectado.\u0026#xa0;La vulnerabilidad es debido a una protecci\u00f3n insuficiente de las credenciales de usuario.\u0026#xa0;Un atacante podr\u00eda explotar esta vulnerabilidad iniciando sesi\u00f3n como usuario administrativo y dise\u00f1ando una llamada para obtener informaci\u00f3n del usuario.\u0026#xa0;Una explotaci\u00f3n con \u00e9xito podr\u00eda permitir al atacante obtener el hash de contrase\u00f1as de los usuarios en un dispositivo afectado" } ], "id": "CVE-2020-26079", "lastModified": "2024-11-21T05:19:11.533", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 4.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:N/A:N", "version": "3.0" }, "exploitabilityScore": 2.3, "impactScore": 1.4, "source": "psirt@cisco.com", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-11-18T18:15:11.997", "references": [ { "source": "psirt@cisco.com", "tags": [ "Vendor Advisory" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-PWH-yCA6M7p" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-PWH-yCA6M7p" } ], "sourceIdentifier": "psirt@cisco.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-256" } ], "source": "psirt@cisco.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-522" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.