Tenda AC18 Router through V15.03.05.05_EN and through V15.03.05.19(6318) CN devices could cause a remote code execution due to incorrect authentication handling of vulnerable logincheck() function in /usr/lib/lua/ngx_authserver/ngx_wdas.lua file if the administrator UI Interface is set to "radius".
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://cwe.mitre.org/data/definitions/287.html | Third Party Advisory | |
cve@mitre.org | https://drive.google.com/file/d/1iqpr0EofOBC6kCq2USTOBPRlJu_naFjQ/view?usp=sharing | Broken Link | |
cve@mitre.org | https://www.tendacn.com/en/product/AC18.html | Product, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cwe.mitre.org/data/definitions/287.html | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://drive.google.com/file/d/1iqpr0EofOBC6kCq2USTOBPRlJu_naFjQ/view?usp=sharing | Broken Link | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.tendacn.com/en/product/AC18.html | Product, Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tendacn | ac18_firmware | * | |
tendacn | ac18 | - | |
tendacn | ac18_firmware | * | |
tendacn | ac18 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tendacn:ac18_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5798E4A8-6F1D-45DB-A253-88033163218C", "versionEndIncluding": "v15.03.05.05_en", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tendacn:ac18:-:*:*:*:*:*:*:*", "matchCriteriaId": "FCF0F551-6E6C-48D6-9C2A-740B84AF0349", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tendacn:ac18_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "677F497C-FD6E-4A6C-A7A9-281E5453A78B", "versionEndIncluding": "v15.03.05.19\\(6318\\)_cn", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tendacn:ac18:-:*:*:*:*:*:*:*", "matchCriteriaId": "FCF0F551-6E6C-48D6-9C2A-740B84AF0349", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC18 Router through V15.03.05.05_EN and through V15.03.05.19(6318) CN devices could cause a remote code execution due to incorrect authentication handling of vulnerable logincheck() function in /usr/lib/lua/ngx_authserver/ngx_wdas.lua file if the administrator UI Interface is set to \"radius\"." }, { "lang": "es", "value": "El enrutador Tenda AC18 versiones hasta V15.03.05.05_EN y versiones hasta V15.03.05.19(6318), los dispositivos CN podr\u00edan causar una ejecuci\u00f3n remota de c\u00f3digo debido a un manejo de autenticaci\u00f3n incorrecto de la funci\u00f3n vulnerable logincheck() en el archivo /usr/lib/lua/ngx_authserver/ngx_wdas.lua si la interfaz de usuario del administrador est\u00e1 configurada en \"radius\"" } ], "id": "CVE-2020-24987", "lastModified": "2024-11-21T05:16:23.240", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-09-04T20:15:13.480", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://cwe.mitre.org/data/definitions/287.html" }, { "source": "cve@mitre.org", "tags": [ "Broken Link" ], "url": "https://drive.google.com/file/d/1iqpr0EofOBC6kCq2USTOBPRlJu_naFjQ/view?usp=sharing" }, { "source": "cve@mitre.org", "tags": [ "Product", "Vendor Advisory" ], "url": "https://www.tendacn.com/en/product/AC18.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://cwe.mitre.org/data/definitions/287.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link" ], "url": "https://drive.google.com/file/d/1iqpr0EofOBC6kCq2USTOBPRlJu_naFjQ/view?usp=sharing" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Product", "Vendor Advisory" ], "url": "https://www.tendacn.com/en/product/AC18.html" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-287" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.