fkie_cve-2020-15942
Vulnerability from fkie_nvd
Published
2021-04-12 15:15
Modified
2024-11-21 05:06
Severity ?
4.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Summary
An information disclosure vulnerability in Web Vulnerability Scan profile of Fortinet's FortiWeb version 6.2.x below 6.2.4 and version 6.3.x below 6.3.5 may allow a remote authenticated attacker to read the password used by the FortiWeb scanner to access the device defined in the scan profile.
References
▼ | URL | Tags | |
---|---|---|---|
psirt@fortinet.com | https://fortiguard.com/advisory/FG-IR-20-076 | Vendor Advisory | |
psirt@fortinet.com | https://www.fortiguard.com/psirt/FG-IR-20-076 | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://fortiguard.com/advisory/FG-IR-20-076 | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.fortiguard.com/psirt/FG-IR-20-076 | Vendor Advisory |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:fortinet:fortiweb:*:*:*:*:*:*:*:*", "matchCriteriaId": "9F6DFE2E-B88E-445F-8248-382880E7AC83", "versionEndIncluding": "6.2.3", "versionStartIncluding": "6.2.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:fortinet:fortiweb:*:*:*:*:*:*:*:*", "matchCriteriaId": "2E6CCBBB-B55D-4B0A-B143-991431B4ED6F", "versionEndIncluding": "6.3.4", "versionStartIncluding": "6.3.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An information disclosure vulnerability in Web Vulnerability Scan profile of Fortinet\u0027s FortiWeb version 6.2.x below 6.2.4 and version 6.3.x below 6.3.5 may allow a remote authenticated attacker to read the password used by the FortiWeb scanner to access the device defined in the scan profile." }, { "lang": "es", "value": "Una vulnerabilidad de divulgaci\u00f3n de informaci\u00f3n en el perfil Web Vulnerability Scan de FortiWeb versiones 6.2.x por debajo de 6.2.4 de Fortinet y versiones 6.3.x por debajo de 6.3.5, puede permitir a un atacante autenticado remoto leer la contrase\u00f1a utilizada por el esc\u00e1ner de FortiWeb para acceder al dispositivo definido en el perfil de escaneo" } ], "id": "CVE-2020-15942", "lastModified": "2024-11-21T05:06:30.160", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 4.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 1.4, "source": "psirt@fortinet.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-04-12T15:15:14.000", "references": [ { "source": "psirt@fortinet.com", "tags": [ "Vendor Advisory" ], "url": "https://fortiguard.com/advisory/FG-IR-20-076" }, { "source": "psirt@fortinet.com", "tags": [ "Vendor Advisory" ], "url": "https://www.fortiguard.com/psirt/FG-IR-20-076" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://fortiguard.com/advisory/FG-IR-20-076" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.fortiguard.com/psirt/FG-IR-20-076" } ], "sourceIdentifier": "psirt@fortinet.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-522" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.