fkie_cve-2020-12011
Vulnerability from fkie_nvd
Published
2020-07-16 19:15
Modified
2024-11-21 04:59
Severity ?
Summary
A specially crafted communication packet sent to the affected systems could cause a denial-of-service condition or allow remote code execution. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; GenBroker32 version 9.5 and prior.
References
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02 | Third Party Advisory, US Government Resource | |
ics-cert@hq.dhs.gov | https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
mitsubishielectric | mc_works | * | |
mitsubishielectric | mc_works32 | 9.50.255.02 | |
iconics | energy_analytix | - | |
iconics | facility_analytix | - | |
iconics | genesis64 | - | |
iconics | hyper_historian | - | |
iconics | mobilehmi | - | |
iconics | quality_analytix | - | |
iconics | smart_energy_analytix | - | |
iconics | bizviz | - | |
iconics | genesis32 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:mitsubishielectric:mc_works:*:*:*:*:*:*:*:*", "matchCriteriaId": "C9B1F646-0D54-4B3A-B39A-A45E1A0615EB", "versionEndIncluding": "10.95.208.31", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mc_works32:9.50.255.02:*:*:*:*:*:*:*", "matchCriteriaId": "A68D91E4-0C65-45F0-965E-A6AAE0E2F09F", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:iconics:energy_analytix:-:*:*:*:*:*:*:*", "matchCriteriaId": "DD143148-B191-4D8E-9C28-09D4AC5D192C", "vulnerable": true }, { "criteria": "cpe:2.3:a:iconics:facility_analytix:-:*:*:*:*:*:*:*", "matchCriteriaId": "BE3C5226-94D4-4826-9B76-72626081DF46", "vulnerable": true }, { "criteria": "cpe:2.3:a:iconics:genesis64:-:*:*:*:*:*:*:*", "matchCriteriaId": "17E644D8-AB8E-4E3C-AE4B-64D3BBCC30BF", "vulnerable": true }, { "criteria": "cpe:2.3:a:iconics:hyper_historian:-:*:*:*:*:*:*:*", "matchCriteriaId": "78FF2A71-4918-491E-A5D8-DEB9E17FA6E4", "vulnerable": true }, { "criteria": "cpe:2.3:a:iconics:mobilehmi:-:*:*:*:*:*:*:*", "matchCriteriaId": "16745C56-A59A-4C38-92E1-FC5C63220989", "vulnerable": true }, { "criteria": "cpe:2.3:a:iconics:quality_analytix:-:*:*:*:*:*:*:*", "matchCriteriaId": "717A4B7B-2A42-4A9C-961F-1EA5E62FB188", "vulnerable": true }, { "criteria": "cpe:2.3:a:iconics:smart_energy_analytix:-:*:*:*:*:*:*:*", "matchCriteriaId": "5082C435-FCCD-4CF6-891E-73F846A6FB40", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:iconics:bizviz:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF628CB2-BCA9-4E69-A9CB-846577F98DA1", "vulnerable": true }, { "criteria": "cpe:2.3:a:iconics:genesis32:-:*:*:*:*:*:*:*", "matchCriteriaId": "771DB32A-CD85-4638-B90E-25D9B4951DE5", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A specially crafted communication packet sent to the affected systems could cause a denial-of-service condition or allow remote code execution. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; GenBroker32 version 9.5 and prior." }, { "lang": "es", "value": "Un paquete de comunicaci\u00f3n especialmente dise\u00f1ado enviado a los sistemas afectados podr\u00eda causar una condici\u00f3n de denegaci\u00f3n de servicio o permitir una ejecuci\u00f3n de c\u00f3digo remota. Este problema afecta: Mitsubishi Electric MC Works64 versi\u00f3n 4.02C (10.95.208.31) y anteriores, todas las versiones; MC Works32 versi\u00f3n 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server versi\u00f3n 10.96 y anteriores; GenBroker32 versi\u00f3n 9.5 y anteriores" } ], "id": "CVE-2020-12011", "lastModified": "2024-11-21T04:59:06.677", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-07-16T19:15:11.830", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.