Multiple memory leaks in Intel AMT in Intel CSME firmware versions before 12.0.5 may allow an unauthenticated user with Intel AMT provisioned to potentially cause a partial denial of service via network access.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_field_pg_m5_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "503E551C-FC5F-4ABC-8DEA-E360701F0B33", "versionEndExcluding": "22.01.06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_field_pg_m5:-:*:*:*:*:*:*:*", "matchCriteriaId": "506DEE00-30D2-4E29-9645-757EB8778C0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc427e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33F546AF-8F80-4E0A-9B92-86E3A1F931C0", "versionEndExcluding": "21.01.09", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc427e:-:*:*:*:*:*:*:*", "matchCriteriaId": "A40D0CDB-7BE6-491F-B730-3B4E10CA159A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc477e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6B5B6E6B-16A0-4236-AABE-82385B53EC78", "versionEndExcluding": "21.01.09", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc477e:-:*:*:*:*:*:*:*", "matchCriteriaId": "FDF9D4C3-1892-48FA-95B4-835B636A4005", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc547e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D476D093-4A97-499C-B40D-7A301BC9AA2E", "versionEndExcluding": "r1.30.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_pc547e:-:*:*:*:*:*:*:*", "matchCriteriaId": "F6A757F1-E478-4A3D-8D5F-C996E176A11A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_pc547g_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "30F129DB-51AC-4F40-A0D1-AB5CF90D9C2D", "versionEndExcluding": "r1.23.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc547g:-:*:*:*:*:*:*:*", "matchCriteriaId": "9EB339B5-602F-4AB5-9998-465FDC6ABD6C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc627d_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "790D244A-AC3D-4BBC-9139-A90048FD375A", "versionEndExcluding": "19.02.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc627d:-:*:*:*:*:*:*:*", "matchCriteriaId": "509AD120-3465-4C00-AAB3-B6F6ED708B51", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc647d_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C046182-BB33-41D0-B041-1566B8041917", "versionEndExcluding": "19.01.14", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc647d:-:*:*:*:*:*:*:*", "matchCriteriaId": "D0EF28FB-BAB3-4710-9D25-25F67ACADC60", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc677d_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8DE74300-E061-452E-AD1D-6DD7C2C62729", "versionEndExcluding": "19.02.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc677d:-:*:*:*:*:*:*:*", "matchCriteriaId": "057D9947-CE4A-4B4C-B721-4B29FB71350C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc827d_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BE4A7C13-6F81-4629-9C28-9202028634AE", "versionEndExcluding": "19.02.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc827d:-:*:*:*:*:*:*:*", "matchCriteriaId": "E6D87239-40C1-4038-B734-D77AC4DDD571", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc847d_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "93485235-481B-4BAF-BB7A-81BB5AA1BC53", "versionEndExcluding": "19.01.14", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc847d:-:*:*:*:*:*:*:*", "matchCriteriaId": "D8F37D88-E086-4060-8420-BD0F8D8FF580", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_itp1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AD949046-46E5-48C9-883B-92F04926E8BC", "versionEndExcluding": "23.01.04", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_itp1000:-:*:*:*:*:*:*:*", "matchCriteriaId": "187C6D51-5B86-484D-AE0F-26D1C9465580", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:intel:converged_security_management_engine_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C23AFAB4-B286-4FD6-ABC3-86B2881E271C", "versionEndExcluding": "12.0.5", "versionStartIncluding": "11.0.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:intel:active_management_technology_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D5FAD938-027A-406F-9E7C-1BFD992839F4", "versionEndExcluding": "12.0.5", "vulnerable": true }, { "criteria": "cpe:2.3:o:intel:manageability_engine_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "63591E72-6038-4417-BA10-54180507AF0F", "versionEndExcluding": "11.0", "versionStartIncluding": "9.0.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Multiple memory leaks in Intel AMT in Intel CSME firmware versions before 12.0.5 may allow an unauthenticated user with Intel AMT provisioned to potentially cause a partial denial of service via network access." }, { "lang": "es", "value": "M\u00faltiples desbordamientos de b\u00fafer en Intel AMT en el firmware Intel CSME en versiones anteriores a la 12.0.5 podr\u00edan permitir que un usuario no autenticado con Intel AMT provisionado provoque una denegaci\u00f3n de servicio (DoS) parcial mediante acceso de red." } ], "id": "CVE-2018-3658", "lastModified": "2024-11-21T04:05:51.020", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 1.4, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-09-12T19:29:02.967", "references": [ { "source": "secure@intel.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/106996" }, { "source": "secure@intel.com", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-377318.pdf" }, { "source": "secure@intel.com", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-043-05" }, { "source": "secure@intel.com", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20180924-0003/" }, { "source": "secure@intel.com", "tags": [ "Third Party Advisory" ], "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03876en_us" }, { "source": "secure@intel.com", "tags": [ "Vendor Advisory" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00141.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/106996" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-377318.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-043-05" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20180924-0003/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03876en_us" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00141.html" } ], "sourceIdentifier": "secure@intel.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-772" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.