FKIE_CVE-2018-3658

Vulnerability from fkie_nvd - Published: 2018-09-12 19:29 - Updated: 2026-06-17 01:57
Summary
Multiple memory leaks in Intel AMT in Intel CSME firmware versions before 12.0.5 may allow an unauthenticated user with Intel AMT provisioned to potentially cause a partial denial of service via network access.

{
  "affected": [
    {
      "affectedData": [
        {
          "product": "Intel(R) Active Management Technology",
          "vendor": "Intel Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "Versions before 12.0.5."
            }
          ]
        }
      ],
      "source": "secure@intel.com"
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_field_pg_m5_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "503E551C-FC5F-4ABC-8DEA-E360701F0B33",
              "versionEndExcluding": "22.01.06",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_field_pg_m5:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "506DEE00-30D2-4E29-9645-757EB8778C0F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc427e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "33F546AF-8F80-4E0A-9B92-86E3A1F931C0",
              "versionEndExcluding": "21.01.09",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc427e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A40D0CDB-7BE6-491F-B730-3B4E10CA159A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc477e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6B5B6E6B-16A0-4236-AABE-82385B53EC78",
              "versionEndExcluding": "21.01.09",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc477e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FDF9D4C3-1892-48FA-95B4-835B636A4005",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc547e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D476D093-4A97-499C-B40D-7A301BC9AA2E",
              "versionEndExcluding": "r1.30.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_pc547e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F6A757F1-E478-4A3D-8D5F-C996E176A11A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_pc547g_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "30F129DB-51AC-4F40-A0D1-AB5CF90D9C2D",
              "versionEndExcluding": "r1.23.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc547g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9EB339B5-602F-4AB5-9998-465FDC6ABD6C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc627d_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "790D244A-AC3D-4BBC-9139-A90048FD375A",
              "versionEndExcluding": "19.02.11",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc627d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "509AD120-3465-4C00-AAB3-B6F6ED708B51",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc647d_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C046182-BB33-41D0-B041-1566B8041917",
              "versionEndExcluding": "19.01.14",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc647d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D0EF28FB-BAB3-4710-9D25-25F67ACADC60",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc677d_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8DE74300-E061-452E-AD1D-6DD7C2C62729",
              "versionEndExcluding": "19.02.11",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc677d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "057D9947-CE4A-4B4C-B721-4B29FB71350C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc827d_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE4A7C13-6F81-4629-9C28-9202028634AE",
              "versionEndExcluding": "19.02.11",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc827d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E6D87239-40C1-4038-B734-D77AC4DDD571",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc847d_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "93485235-481B-4BAF-BB7A-81BB5AA1BC53",
              "versionEndExcluding": "19.01.14",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc847d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8F37D88-E086-4060-8420-BD0F8D8FF580",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_itp1000_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD949046-46E5-48C9-883B-92F04926E8BC",
              "versionEndExcluding": "23.01.04",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_itp1000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "187C6D51-5B86-484D-AE0F-26D1C9465580",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:intel:converged_security_management_engine_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C23AFAB4-B286-4FD6-ABC3-86B2881E271C",
              "versionEndExcluding": "12.0.5",
              "versionStartIncluding": "11.0.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:intel:active_management_technology_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D5FAD938-027A-406F-9E7C-1BFD992839F4",
              "versionEndExcluding": "12.0.5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:intel:manageability_engine_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "63591E72-6038-4417-BA10-54180507AF0F",
              "versionEndExcluding": "11.0",
              "versionStartIncluding": "9.0.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Multiple memory leaks in Intel AMT in Intel CSME firmware versions before 12.0.5 may allow an unauthenticated user with Intel AMT provisioned to potentially cause a partial denial of service via network access."
    },
    {
      "lang": "es",
      "value": "M\u00faltiples desbordamientos de b\u00fafer en Intel AMT en el firmware Intel CSME en versiones anteriores a la 12.0.5 podr\u00edan permitir que un usuario no autenticado con Intel AMT provisionado provoque una denegaci\u00f3n de servicio (DoS) parcial mediante acceso de red."
    }
  ],
  "id": "CVE-2018-3658",
  "lastModified": "2026-06-17T01:57:38.327",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.0,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 5.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 1.4,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-09-12T19:29:02.967",
  "references": [
    {
      "source": "secure@intel.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/106996"
    },
    {
      "source": "secure@intel.com",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-377318.pdf"
    },
    {
      "source": "secure@intel.com",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-043-05"
    },
    {
      "source": "secure@intel.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.netapp.com/advisory/ntap-20180924-0003/"
    },
    {
      "source": "secure@intel.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03876en_us"
    },
    {
      "source": "secure@intel.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00141.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/106996"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-377318.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-043-05"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.netapp.com/advisory/ntap-20180924-0003/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03876en_us"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00141.html"
    }
  ],
  "sourceIdentifier": "secure@intel.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-772"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…