fkie_cve-2017-8414
Vulnerability from fkie_nvd
Published
2019-07-02 20:15
Modified
2024-11-21 03:33
Summary
An issue was discovered on D-Link DCS-1100 and DCS-1130 devices. The binary orthrus in /sbin folder of the device handles all the UPnP connections received by the device. It seems that the binary performs a sprintf operation at address 0x0000A3E4 with the value in the command line parameter "-f" and stores it on the stack. Since there is no length check, this results in corrupting the registers for the function sub_A098 which results in memory corruption.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dcs-1100_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "554817F7-7E3D-4D69-90AC-46D86056143B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dcs-1100:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "704F9608-72CE-49C0-B7D2-F2FE84DF0C74",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dcs-1130_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0DB53465-4FE2-43EF-B2C6-839DFEA80D62",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dcs-1130:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "33A388EC-275D-4180-83E2-AD73F7EEB54F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered on D-Link DCS-1100 and DCS-1130 devices. The binary orthrus in /sbin folder of the device handles all the UPnP connections received by the device. It seems that the binary performs a sprintf operation at address 0x0000A3E4 with the value in the command line parameter \"-f\" and stores it on the stack. Since there is no length check, this results in corrupting the registers for the function sub_A098 which results in memory corruption."
    },
    {
      "lang": "es",
      "value": "Se detect\u00f3 un problema en los dispositivos DCS-1100 y DCS-1130 de D-Link. El orthrus binario en la carpeta /sbin del dispositivo maneja todas las conexiones UPnP recibidas por el mismo. Al parecer el binario realiza una operaci\u00f3n sprintf en la direcci\u00f3n 0x0000A3E4 con el valor en el par\u00e1metro de l\u00ednea de comando \"-f\" y lo almacena en la pila. En vista de que no hay una comprobaci\u00f3n de longitud, esto resulta en una corrupci\u00f3n de los registros para la funci\u00f3n sub_A098, que resulta en una corrupci\u00f3n de la memoria."
    }
  ],
  "id": "CVE-2017-8414",
  "lastModified": "2024-11-21T03:33:59.643",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.2,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-07-02T20:15:11.200",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://packetstormsecurity.com/files/153226/Dlink-DCS-1130-Command-Injection-CSRF-Stack-Overflow.html"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Dlink_DCS_1130_security.pdf"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "https://seclists.org/bugtraq/2019/Jun/8"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://packetstormsecurity.com/files/153226/Dlink-DCS-1130-Command-Injection-CSRF-Stack-Overflow.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Dlink_DCS_1130_security.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "https://seclists.org/bugtraq/2019/Jun/8"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.