fkie_cve-2017-6717
Vulnerability from fkie_nvd
Published
2017-07-04 00:29
Modified
2025-04-20 01:37
Severity ?
Summary
A vulnerability in the web framework of Cisco Firepower Management Center could allow an authenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the web interface. More Information: CSCvc38801. Known Affected Releases: 6.0.1.3 6.2.1. Known Fixed Releases: 6.2.1.
References
| URL | Tags | ||
|---|---|---|---|
| psirt@cisco.com | http://www.securityfocus.com/bid/99217 | Third Party Advisory, VDB Entry | |
| psirt@cisco.com | https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170621-fpmc | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/99217 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170621-fpmc | Vendor Advisory |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:5.4.0:*:*:*:*:*:*:*",
"matchCriteriaId": "27EA38C1-A34F-430A-92F7-1D299F78B449",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:5.4.0.2:*:*:*:*:*:*:*",
"matchCriteriaId": "DE5CF68A-AAF1-4103-AD83-E2192785B31B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:5.4.1:*:*:*:*:*:*:*",
"matchCriteriaId": "38ACE806-3514-4D95-85DA-BAD7245011A0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:5.4.1.1:*:*:*:*:*:*:*",
"matchCriteriaId": "1898CADB-3B2B-4A3E-86DD-23A9E1A3E40F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:5.4.1.2:*:*:*:*:*:*:*",
"matchCriteriaId": "8D6B5ED0-0E42-45A2-BBBB-148C2BE5DD14",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:5.4.1.3:*:*:*:*:*:*:*",
"matchCriteriaId": "0091657B-E242-4664-8F2F-85B8FCDF3EE8",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:5.4.1.4:*:*:*:*:*:*:*",
"matchCriteriaId": "95D7DA95-E977-4D06-92C8-E4E8B464E1D2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:5.4.1.5:*:*:*:*:*:*:*",
"matchCriteriaId": "15B5C864-D82A-43BB-B193-CB9756A3B8BC",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:5.4.1.6:*:*:*:*:*:*:*",
"matchCriteriaId": "AA8E3657-BC3D-4A7D-8523-0D64F69CFE8E",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:5.4.1.9:*:*:*:*:*:*:*",
"matchCriteriaId": "3614E72A-667E-47F4-8D42-C1EB210E4DB5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:5.4_base:*:*:*:*:*:*:*",
"matchCriteriaId": "9B2E1AA9-8A80-489A-8A6F-E9034E7D2A82",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:6.0.0:*:*:*:*:*:*:*",
"matchCriteriaId": "036E4035-E8E2-4964-A6F4-7292E1804E91",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:6.0.0.0:*:*:*:*:*:*:*",
"matchCriteriaId": "AF40DB44-C213-466E-B473-B07B30A42B34",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:6.0.0.1:*:*:*:*:*:*:*",
"matchCriteriaId": "B6FD6283-CC58-4864-AA24-F6C6DDE630FC",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:6.0.1:*:*:*:*:*:*:*",
"matchCriteriaId": "6D1AFAC1-419D-4ADB-868B-1544BED58B7F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:6.0.1.1:*:*:*:*:*:*:*",
"matchCriteriaId": "6D4EB1FD-690B-4F8C-A559-BC76CA5FDEFF",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:6.0.1.3:*:*:*:*:*:*:*",
"matchCriteriaId": "9D184D6D-D695-48D5-90E6-95185C1D397D",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:6.0_base:*:*:*:*:*:*:*",
"matchCriteriaId": "554F229F-A0F5-4CA9-9778-5585E01ADF6E",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:6.1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "6614ED6C-E77E-4C0D-AA96-0BEE84BE2F94",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:6.1.0.2:*:*:*:*:*:*:*",
"matchCriteriaId": "53316FAB-A54F-4AB8-B605-FF042B903BFD",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:6.2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "EEEB9A40-0062-406D-B56D-3163CBBE08D4",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:6.2.0.2:*:*:*:*:*:*:*",
"matchCriteriaId": "55C748E1-1011-4DA3-B910-C4773DC18D4C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the web framework of Cisco Firepower Management Center could allow an authenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the web interface. More Information: CSCvc38801. Known Affected Releases: 6.0.1.3 6.2.1. Known Fixed Releases: 6.2.1."
},
{
"lang": "es",
"value": "Una vulnerabilidad en el framework web de Firepower Management Center de Cisco, podr\u00eda permitir a un atacante remoto identificado conducir un ataque de tipo cross-site scripting (XSS) contra un usuario de la interfaz web. M\u00e1s informaci\u00f3n: CSCvc38801. Versiones Afectadas Conocidas: 6.0.1.3 6.2.1. Versiones Fijas Conocidas: 6.2.1."
}
],
"id": "CVE-2017-6717",
"lastModified": "2025-04-20T01:37:25.860",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 6.8,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.0"
},
"exploitabilityScore": 2.3,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2017-07-04T00:29:00.587",
"references": [
{
"source": "psirt@cisco.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/99217"
},
{
"source": "psirt@cisco.com",
"tags": [
"Vendor Advisory"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170621-fpmc"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/99217"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170621-fpmc"
}
],
"sourceIdentifier": "psirt@cisco.com",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…