fkie_cve-2017-18859
Vulnerability from fkie_nvd
Published
2020-04-28 17:15
Modified
2024-11-21 03:21
Severity ?
Summary
Certain NETGEAR devices are affected by slowdown/stoppage. This affects C6300 before 2017-05-30, CM400 before 2017-05-30, CM700 before 2017-05-30, and CMD31T before 2017-05-30.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | c6300_firmware | * | |
netgear | c6300 | - | |
netgear | cm400_firmware | * | |
netgear | cm400 | - | |
netgear | cm700_firmware | * | |
netgear | cm700 | - | |
netgear | cmd31t_firmware | * | |
netgear | cmd31t | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:c6300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7C10E1EC-D4A4-4E7F-939E-CBBA08AFC493", "versionEndExcluding": "2017-05-30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:c6300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7185DE0B-B15C-417D-9AF5-FBF15F9C2241", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cm400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0A510197-2782-46BE-93EC-A506F2B290EE", "versionEndExcluding": "2017-05-30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cm400:-:*:*:*:*:*:*:*", "matchCriteriaId": "5AC8E42B-BF1A-47D5-A01F-F1063897D04A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cm700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D6503A8D-C2CF-407F-A205-1E551C7AB044", "versionEndExcluding": "2017-05-30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cm700:-:*:*:*:*:*:*:*", "matchCriteriaId": "0D13E46E-C2AE-408C-8408-0436B00ED8A3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cmd31t_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8E3630EA-A8BF-4BDA-B245-3500B434A60F", "versionEndExcluding": "2017-05-30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cmd31t:-:*:*:*:*:*:*:*", "matchCriteriaId": "4B9C4D0C-750C-43BB-98A9-81BB0185F317", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by slowdown/stoppage. This affects C6300 before 2017-05-30, CM400 before 2017-05-30, CM700 before 2017-05-30, and CMD31T before 2017-05-30." }, { "lang": "es", "value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por una ralentizaci\u00f3n y parada. Esto afecta a C6300 antes del 30-05-2017, CM400 antes del 30-05-2017, CM700 antes del 30-05-2017, y CMD31T antes del 30-05-2017." } ], "id": "CVE-2017-18859", "lastModified": "2024-11-21T03:21:06.780", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T17:15:12.790", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000038560/Security-Advisory-for-Vulnerability-on-Select-Cable-Modems-and-Gateways-PSV-2017-2165" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000038560/Security-Advisory-for-Vulnerability-on-Select-Cable-Modems-and-Gateways-PSV-2017-2165" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.