fkie_cve-2017-18847
Vulnerability from fkie_nvd
Published
2020-04-20 16:15
Modified
2024-11-21 03:21
Summary
Certain NETGEAR devices are affected by an attacker's ability to read arbitrary files. This affects R6400v2 before 1.0.2.32, R7000P/R6900P before 1.0.0.56, R7900 before 1.0.1.18, R8300 before 1.0.2.100_1.0.82, R8500 before 1.0.2.100_1.0.82, and D8500 before 1.0.3.29.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DB7B08B9-07D2-4404-846A-D1CA02C16557",
              "versionEndExcluding": "1.0.2.32",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r6400:v2:*:*:*:*:*:*:*",
              "matchCriteriaId": "52AE9AD2-BC8D-477D-A3D3-891AE52FA5F3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "ADFE7176-BD34-467C-A167-E869E04A8E97",
              "versionEndExcluding": "1.0.0.56",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E9EF43B-2542-44CE-A1D6-DECCCFBC1F5F",
              "versionEndExcluding": "1.0.0.56",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A98DFA81-D1BA-41AE-A6A3-1EBBFC452D0F",
              "versionEndExcluding": "1.0.1.18",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FA4A3678-F7BB-453F-A245-58E58116415B",
              "versionEndExcluding": "1.0.2.100_1.0.82",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7A9B77E7-7439-48C6-989F-5E22CB4D3044",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BAEFC983-46C7-49F2-8A65-7014BB703036",
              "versionEndExcluding": "1.0.2.100_1.0.82",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "63500DE4-BDBD-4F86-AB99-7DB084D0B912",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "20564DE0-E58D-4628-ADD6-AC7C90AD85F7",
              "versionEndExcluding": "1.0.3.29",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "814A0114-9A1D-4EA0-9AF4-6968514E4F01",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Certain NETGEAR devices are affected by an attacker\u0027s ability to read arbitrary files. This affects R6400v2 before 1.0.2.32, R7000P/R6900P before 1.0.0.56, R7900 before 1.0.1.18, R8300 before 1.0.2.100_1.0.82, R8500 before 1.0.2.100_1.0.82, and D8500 before 1.0.3.29."
    },
    {
      "lang": "es",
      "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por la capacidad de un atacante para leer archivos arbitrarios. Esto afecta a R6400v2 versiones anteriores a 1.0.2.32, R7000P/R6900P versiones anteriores a 1.0.0.56, R7900 versiones anteriores a 1.0.1.18, R8300 versiones anteriores a 1.0.2.100_1.0.82, R8500 versiones anteriores a 1.0.2.100_1.0.82, y D8500 versiones anteriores a 1.0.3.29."
    }
  ],
  "id": "CVE-2017-18847",
  "lastModified": "2024-11-21T03:21:04.887",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 2.1,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 6.2,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.0"
        },
        "exploitabilityScore": 2.5,
        "impactScore": 3.6,
        "source": "cve@mitre.org",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-04-20T16:15:13.787",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000049012/Security-Advisory-for-Arbitrary-File-Read-on-Some-Routers-PSV-PSV-2017-0783"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000049012/Security-Advisory-for-Arbitrary-File-Read-on-Some-Routers-PSV-PSV-2017-0783"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-200"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.