A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02; SIPROTEC 7SJ686 : All versions < V 4.87; SIPROTEC 7UT686 : All versions < V 4.02; SIPROTEC 7SD686 : All versions < V 4.05; SIPROTEC 7SJ66 : All versions < V 4.30. Attackers with network access to the device's web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations. A legitimate user must be logged into the web interface for the attack to be successful.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | en100_ethernet_module_firmware | 4.28 | |
siemens | en100_ethernet_module | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:en100_ethernet_module_firmware:4.28:*:*:*:*:*:*:*", "matchCriteriaId": "862476A4-6C97-4E00-9EC1-5EEA8A27EE73", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:en100_ethernet_module:-:*:*:*:*:*:*:*", "matchCriteriaId": "DAC429FD-7148-4A68-AA81-8FBADA588F4E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02; SIPROTEC 7SJ686 : All versions \u003c V 4.87; SIPROTEC 7UT686 : All versions \u003c V 4.02; SIPROTEC 7SD686 : All versions \u003c V 4.05; SIPROTEC 7SJ66 : All versions \u003c V 4.30. Attackers with network access to the device\u0027s web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations. A legitimate user must be logged into the web interface for the attack to be successful." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en la variante de Firmware PROFINET IO para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.04.01; la variante de Firmware Modbus TCP para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.11.00; la variante de Firmware v TCP para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.03; la variante de Firmware IEC 104 para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.21 y el m\u00f3dulo EN100 Ethernet incluido en SIPROTEC Merging Unit 6MU80: todas las versiones anteriores a la 1.02.02; SIPROTEC 7SJ686: todas las versiones anteriores a la V 4.87 y SIPROTEC 7UT686: todas las versiones anteriores a la V 4.02 y SIPROTEC 7SD686: todas las versiones anteriores a la V 4.05 y SIPROTEC 7SJ66: todas las versiones anteriores a la V 4.30. Los atacantes que tengan acceso de red a la interfaz web del dispositivo (puerto 80/tcp) podr\u00edan omitir la autenticaci\u00f3n y realizar ciertas operaciones administrativas. Un usuario leg\u00edtimo debe tener la sesi\u00f3n iniciada en la interfaz web para que el ataque tenga \u00e9xito." } ], "id": "CVE-2016-7114", "lastModified": "2024-11-21T02:57:29.550", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2016-09-06T00:59:02.977", "references": [ { "source": "cve@mitre.org", "url": "http://www.securityfocus.com/bid/92745" }, { "source": "cve@mitre.org", "url": "http://www.securityfocus.com/bid/99471" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf" }, { "source": "cve@mitre.org", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03" }, { "source": "cve@mitre.org", "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://www.securityfocus.com/bid/92745" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://www.securityfocus.com/bid/99471" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-287" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.