fkie_cve-2012-2516
Vulnerability from fkie_nvd
Published
2012-07-05 03:23
Modified
2024-11-21 01:39
Severity ?
Summary
An ActiveX control in KeyHelp.ocx in KeyWorks KeyHelp Module (aka the HTML Help component), as used in GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; Proficy HMI/SCADA iFIX 5.0 and 5.1; Proficy Pulse 1.0; Proficy Batch Execution 5.6; SI7 I/O Driver 7.20 through 7.42; and other products, allows remote attackers to execute arbitrary commands via crafted input, related to a "command injection vulnerability."
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_batch_execution:5.6:*:*:*:*:*:*:*", "matchCriteriaId": "0D91A768-D643-4601-B11D-2C5FB60B8566", "vulnerable": true }, { "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_historian:3.1:*:*:*:*:*:*:*", "matchCriteriaId": "612B7F05-3C6D-43CA-8D6C-F0A887789EF5", "vulnerable": true }, { "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_historian:3.5:*:*:*:*:*:*:*", "matchCriteriaId": "6D29C00B-B754-47C5-BBD0-D63DDD252DA6", "vulnerable": true }, { "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_historian:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "6BC9F852-EA9A-497D-9ED2-DAF926D0440A", "vulnerable": true }, { "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_historian:4.5:*:*:*:*:*:*:*", "matchCriteriaId": "2C8C84F4-699E-4D77-AF36-19DF28AE16CC", "vulnerable": true }, { "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_ifix:5.0:*:*:*:*:*:*:*", "matchCriteriaId": "65A4CBC3-3B98-4700-8710-4D4FFCA55315", "vulnerable": true }, { "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_ifix:5.1:*:*:*:*:*:*:*", "matchCriteriaId": "5ABA340B-B00B-41EC-8270-68139B63D09A", "vulnerable": true }, { "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_pulse:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "738ACF30-4F1A-44C6-9A97-46F5566ACC05", "vulnerable": true }, { "criteria": "cpe:2.3:a:ge:intelligent_platforms_si7_i\\/o_driver:7.20:*:*:*:*:*:*:*", "matchCriteriaId": "641F3A0F-9E07-413D-869C-8E123636DD0A", "vulnerable": true }, { "criteria": "cpe:2.3:a:ge:intelligent_platforms_si7_i\\/o_driver:7.42:*:*:*:*:*:*:*", "matchCriteriaId": "FA786450-C420-420A-9C5E-49D408B6B3C2", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An ActiveX control in KeyHelp.ocx in KeyWorks KeyHelp Module (aka the HTML Help component), as used in GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; Proficy HMI/SCADA iFIX 5.0 and 5.1; Proficy Pulse 1.0; Proficy Batch Execution 5.6; SI7 I/O Driver 7.20 through 7.42; and other products, allows remote attackers to execute arbitrary commands via crafted input, related to a \"command injection vulnerability.\"" }, { "lang": "es", "value": "Un control ActiveX en KeyHelp.ocx en KeyWorks KeyHelp Module (tambi\u00e9n conocido como el componente HTML Help), tal como se utiliza en GE Intelligent Platforms Proficy Historian v3.1, v3.5, v4.0 y v4.5; Proficy HMI/SCADA iFIX v5.0 y v5.1; Proficy Pulse v1,0; Proficy Batch Execution v5,6, SI7 ??E/S Driverv 7.20 hasta 7.42, y otros productos, permite a atacantes remotos ejecutar comandos arbitrarios a trav\u00e9s de la entrada hecha a mano, relacionada con una \"vulnerabilidad de inyecci\u00f3n de comandos.\"" } ], "id": "CVE-2012-2516", "lastModified": "2024-11-21T01:39:10.333", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ] }, "published": "2012-07-05T03:23:18.527", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Vendor Advisory" ], "url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/14000/KB14863/en_US/GEIP12-04%20Security%20Advisory%20-%20Proficy%20HTML%20Help.pdf" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "US Government Resource" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-02.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/14000/KB14863/en_US/GEIP12-04%20Security%20Advisory%20-%20Proficy%20HTML%20Help.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "US Government Resource" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-02.pdf" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.