CVE-2026-15570 (GCVE-0-2026-15570)
Vulnerability from cvelistv5 – Published: 2026-08-07 13:32 – Updated: 2026-08-07 14:26
VLAI
EPSS
VEX
Title
Improper URL Scheme and Destination Validation in SmartCenter browserseturl Command
Summary
An improper restriction of URL schemes and destinations in the SmartCenter browserseturl command in the Telefunken TE24553B45V2DZ Smart TV running on the Vestel MB181 / Voltron181 / TiVo OS platform allows an attacker with access to the same local network to cause the embedded browser to issue requests to unintended loopback/internal destinations, including 127.0.0.1 addresses. In demonstrated scenarios, requests initiated through the SmartCenter browserseturl mechanism could reach an internal service and receive a successful response, although the same destination was not reachable through normal browser navigation. The issue affects firmware version V2.78.0.0 and is fixed in firmware version V2.85.2.0.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-918 - Server-Side request forgery (SSRF)
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://firebasestorage.googleapis.com/v0/b/veste… | vendor-advisory |
| https://vestelinternational.com/security-advisories | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Vestel | Telefunken TE24553B45V2DZ Smart TV |
Affected:
V2.78.0.0
Unaffected: V2.85.2.0 |
Date Public
2026-08-07 13:13
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-15570",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-07T14:25:53.841501Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-07T14:26:15.788Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"modules": [
"Smart Center",
"browserseturl command"
],
"platforms": [
"Vestel MB181 / Voltron181 / TiVo OS"
],
"product": "Telefunken TE24553B45V2DZ Smart TV",
"vendor": "Vestel",
"versions": [
{
"status": "affected",
"version": "V2.78.0.0"
},
{
"status": "unaffected",
"version": "V2.85.2.0"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Francesco Caligiuri"
}
],
"datePublic": "2026-08-07T13:13:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An improper restriction of URL schemes and destinations in the SmartCenter browserseturl command in the Telefunken TE24553B45V2DZ Smart TV running on the Vestel MB181 / Voltron181 / TiVo OS platform allows an attacker with access to the same local network to cause the embedded browser to issue requests to unintended loopback/internal destinations, including 127.0.0.1 addresses. In demonstrated scenarios, requests initiated through the SmartCenter browserseturl mechanism could reach an internal service and receive a successful response, although the same destination was not reachable through normal browser navigation. The issue affects firmware version V2.78.0.0 and is fixed in firmware version V2.85.2.0."
}
],
"value": "An improper restriction of URL schemes and destinations in the SmartCenter browserseturl command in the Telefunken TE24553B45V2DZ Smart TV running on the Vestel MB181 / Voltron181 / TiVo OS platform allows an attacker with access to the same local network to cause the embedded browser to issue requests to unintended loopback/internal destinations, including 127.0.0.1 addresses. In demonstrated scenarios, requests initiated through the SmartCenter browserseturl mechanism could reach an internal service and receive a successful response, although the same destination was not reachable through normal browser navigation. The issue affects firmware version V2.78.0.0 and is fixed in firmware version V2.85.2.0."
}
],
"impacts": [
{
"capecId": "CAPEC-664",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-664 Server Side Request Forgery"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-918",
"description": "CWE-918 Server-Side request forgery (SSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-07T13:32:45.790Z",
"orgId": "5431be70-064b-4f6a-be51-69eacabef109",
"shortName": "Vestel"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://firebasestorage.googleapis.com/v0/b/vestel-shield.firebasestorage.app/o/PRODUCTION%2F4%2FVSA-4.pdf?alt=media\u0026token=61fb45d3-b88e-4810-a620-693a1c693db4"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://vestelinternational.com/security-advisories"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Upgrade the affected product to firmware version V2.85.2.0."
}
],
"value": "Upgrade the affected product to firmware version V2.85.2.0."
}
],
"source": {
"advisory": "VSA-4",
"discovery": "UNKNOWN"
},
"title": "Improper URL Scheme and Destination Validation in SmartCenter browserseturl Command",
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "5431be70-064b-4f6a-be51-69eacabef109",
"assignerShortName": "Vestel",
"cveId": "CVE-2026-15570",
"datePublished": "2026-08-07T13:32:45.790Z",
"dateReserved": "2026-07-13T07:02:12.638Z",
"dateUpdated": "2026-08-07T14:26:15.788Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2026-15570",
"date": "2026-08-10",
"epss": "0.00207",
"percentile": "0.10931"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2026-15570\",\"sourceIdentifier\":\"5431be70-064b-4f6a-be51-69eacabef109\",\"published\":\"2026-08-07T14:16:56.890\",\"lastModified\":\"2026-08-07T15:16:59.197\",\"vulnStatus\":\"Received\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An improper restriction of URL schemes and destinations in the SmartCenter browserseturl command in the Telefunken TE24553B45V2DZ Smart TV running on the Vestel MB181 / Voltron181 / TiVo OS platform allows an attacker with access to the same local network to cause the embedded browser to issue requests to unintended loopback/internal destinations, including 127.0.0.1 addresses. In demonstrated scenarios, requests initiated through the SmartCenter browserseturl mechanism could reach an internal service and receive a successful response, although the same destination was not reachable through normal browser navigation. The issue affects firmware version V2.78.0.0 and is fixed in firmware version V2.85.2.0.\"}],\"affected\":[{\"source\":\"5431be70-064b-4f6a-be51-69eacabef109\",\"affectedData\":[{\"vendor\":\"Vestel\",\"product\":\"Telefunken TE24553B45V2DZ Smart TV\",\"defaultStatus\":\"unknown\",\"modules\":[\"Smart Center\",\"browserseturl command\"],\"platforms\":[\"Vestel MB181 / Voltron181 / TiVo OS\"],\"versions\":[{\"version\":\"V2.78.0.0\",\"status\":\"affected\"},{\"version\":\"V2.85.2.0\",\"status\":\"unaffected\"}]}]}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"5431be70-064b-4f6a-be51-69eacabef109\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":7.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"ADJACENT\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"NONE\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"LOW\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"ssvcV203\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"ssvcData\":{\"timestamp\":\"2026-08-07T14:25:53.841501Z\",\"id\":\"CVE-2026-15570\",\"options\":[{\"exploitation\":\"none\"},{\"automatable\":\"no\"},{\"technicalImpact\":\"partial\"}],\"role\":\"CISA Coordinator\",\"version\":\"2.0.3\"}}]},\"weaknesses\":[{\"source\":\"5431be70-064b-4f6a-be51-69eacabef109\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-918\"}]}],\"references\":[{\"url\":\"https://firebasestorage.googleapis.com/v0/b/vestel-shield.firebasestorage.app/o/PRODUCTION%2F4%2FVSA-4.pdf?alt=media\u0026token=61fb45d3-b88e-4810-a620-693a1c693db4\",\"source\":\"5431be70-064b-4f6a-be51-69eacabef109\"},{\"url\":\"https://vestelinternational.com/security-advisories\",\"source\":\"5431be70-064b-4f6a-be51-69eacabef109\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-15570\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-08-07T14:25:53.841501Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-08-07T14:25:59.979Z\"}}], \"cna\": {\"title\": \"Improper URL Scheme and Destination Validation in SmartCenter browserseturl Command\", \"source\": {\"advisory\": \"VSA-4\", \"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Francesco Caligiuri\"}], \"impacts\": [{\"capecId\": \"CAPEC-664\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-664 Server Side Request Forgery\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 7.1, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"ADJACENT\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N\", \"exploitMaturity\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"LOW\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"NONE\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Vestel\", \"modules\": [\"Smart Center\", \"browserseturl command\"], \"product\": \"Telefunken TE24553B45V2DZ Smart TV\", \"versions\": [{\"status\": \"affected\", \"version\": \"V2.78.0.0\"}, {\"status\": \"unaffected\", \"version\": \"V2.85.2.0\"}], \"platforms\": [\"Vestel MB181 / Voltron181 / TiVo OS\"], \"defaultStatus\": \"unknown\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Upgrade the affected product to firmware version V2.85.2.0.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Upgrade the affected product to firmware version V2.85.2.0.\", \"base64\": false}]}], \"datePublic\": \"2026-08-07T13:13:00.000Z\", \"references\": [{\"url\": \"https://firebasestorage.googleapis.com/v0/b/vestel-shield.firebasestorage.app/o/PRODUCTION%2F4%2FVSA-4.pdf?alt=media\u0026token=61fb45d3-b88e-4810-a620-693a1c693db4\", \"tags\": [\"vendor-advisory\"]}, {\"url\": \"https://vestelinternational.com/security-advisories\", \"tags\": [\"vendor-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 1.0.4\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"An improper restriction of URL schemes and destinations in the SmartCenter browserseturl command in the Telefunken TE24553B45V2DZ Smart TV running on the Vestel MB181 / Voltron181 / TiVo OS platform allows an attacker with access to the same local network to cause the embedded browser to issue requests to unintended loopback/internal destinations, including 127.0.0.1 addresses. In demonstrated scenarios, requests initiated through the SmartCenter browserseturl mechanism could reach an internal service and receive a successful response, although the same destination was not reachable through normal browser navigation. The issue affects firmware version V2.78.0.0 and is fixed in firmware version V2.85.2.0.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"An improper restriction of URL schemes and destinations in the SmartCenter browserseturl command in the Telefunken TE24553B45V2DZ Smart TV running on the Vestel MB181 / Voltron181 / TiVo OS platform allows an attacker with access to the same local network to cause the embedded browser to issue requests to unintended loopback/internal destinations, including 127.0.0.1 addresses. In demonstrated scenarios, requests initiated through the SmartCenter browserseturl mechanism could reach an internal service and receive a successful response, although the same destination was not reachable through normal browser navigation. The issue affects firmware version V2.78.0.0 and is fixed in firmware version V2.85.2.0.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-918\", \"description\": \"CWE-918 Server-Side request forgery (SSRF)\"}]}], \"providerMetadata\": {\"orgId\": \"5431be70-064b-4f6a-be51-69eacabef109\", \"shortName\": \"Vestel\", \"dateUpdated\": \"2026-08-07T13:32:45.790Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2026-15570\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-08-07T14:26:15.788Z\", \"dateReserved\": \"2026-07-13T07:02:12.638Z\", \"assignerOrgId\": \"5431be70-064b-4f6a-be51-69eacabef109\", \"datePublished\": \"2026-08-07T13:32:45.790Z\", \"assignerShortName\": \"Vestel\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
Loading…
Loading…