CVE-2025-5965 (GCVE-0-2025-5965)
Vulnerability from cvelistv5 – Published: 2026-01-05 10:06 – Updated: 2026-01-08 15:43
VLAI?
Title
RCE via the backup feature available only to user with high privilege
Summary
In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Backup configuration in the administration setup modules) allows OS Command Injection.This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Centreon | Infra Monitoring |
Affected:
25.10.0 , < 25.10.2
(semver)
Affected: 24.10.0 , < 24.10.15 (semver) Affected: 24.04.0 , < 24.04.19 (semver) |
Credits
h00die-gr3y
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-5965",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-05T20:01:00.415596Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-05T20:01:20.692Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"Backup configuration in the administration setup"
],
"product": "Infra Monitoring",
"vendor": "Centreon",
"versions": [
{
"lessThan": "25.10.2",
"status": "affected",
"version": "25.10.0",
"versionType": "semver"
},
{
"lessThan": "24.10.15",
"status": "affected",
"version": "24.10.0",
"versionType": "semver"
},
{
"lessThan": "24.04.19",
"status": "affected",
"version": "24.04.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "h00die-gr3y"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Centreon Infra Monitoring (Backup configuration in the administration setup modules) allows OS Command Injection.\u003cp\u003eThis issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.\u003c/p\u003e"
}
],
"value": "In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Centreon Infra Monitoring (Backup configuration in the administration setup modules) allows OS Command Injection.This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-08T15:43:03.373Z",
"orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
"shortName": "Centreon"
},
"references": [
{
"tags": [
"release-notes"
],
"url": "https://github.com/centreon/centreon/releases"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-5965-centreon-web-high-severity-5362"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "RCE via the backup feature available only to user with high privilege",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
"assignerShortName": "Centreon",
"cveId": "CVE-2025-5965",
"datePublished": "2026-01-05T10:06:05.494Z",
"dateReserved": "2025-06-10T08:14:47.529Z",
"dateUpdated": "2026-01-08T15:43:03.373Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2025-5965\",\"sourceIdentifier\":\"bd4443e6-1eef-43f3-9886-25fc9ceeaae7\",\"published\":\"2026-01-05T10:15:55.870\",\"lastModified\":\"2026-01-08T18:09:49.800\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Centreon Infra Monitoring (Backup configuration in the administration setup modules) allows OS Command Injection.This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"bd4443e6-1eef-43f3-9886-25fc9ceeaae7\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"bd4443e6-1eef-43f3-9886-25fc9ceeaae7\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"references\":[{\"url\":\"https://github.com/centreon/centreon/releases\",\"source\":\"bd4443e6-1eef-43f3-9886-25fc9ceeaae7\"},{\"url\":\"https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-5965-centreon-web-high-severity-5362\",\"source\":\"bd4443e6-1eef-43f3-9886-25fc9ceeaae7\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-5965\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-01-05T20:01:00.415596Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-01-05T20:01:17.220Z\"}}], \"cna\": {\"title\": \"RCE via the backup feature available only to user with high privilege\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"h00die-gr3y\"}], \"impacts\": [{\"capecId\": \"CAPEC-88\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-88 OS Command Injection\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.2, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Centreon\", \"modules\": [\"Backup configuration in the administration setup\"], \"product\": \"Infra Monitoring\", \"versions\": [{\"status\": \"affected\", \"version\": \"25.10.0\", \"lessThan\": \"25.10.2\", \"versionType\": \"semver\"}, {\"status\": \"affected\", \"version\": \"24.10.0\", \"lessThan\": \"24.10.15\", \"versionType\": \"semver\"}, {\"status\": \"affected\", \"version\": \"24.04.0\", \"lessThan\": \"24.04.19\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://github.com/centreon/centreon/releases\", \"tags\": [\"release-notes\"]}, {\"url\": \"https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-5965-centreon-web-high-severity-5362\", \"tags\": [\"vendor-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Centreon Infra Monitoring (Backup configuration in the administration setup modules) allows OS Command Injection.This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Centreon Infra Monitoring (Backup configuration in the administration setup modules) allows OS Command Injection.\u003cp\u003eThis issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.\u003c/p\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-78\", \"description\": \"CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"bd4443e6-1eef-43f3-9886-25fc9ceeaae7\", \"shortName\": \"Centreon\", \"dateUpdated\": \"2026-01-08T15:43:03.373Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-5965\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-01-08T15:43:03.373Z\", \"dateReserved\": \"2025-06-10T08:14:47.529Z\", \"assignerOrgId\": \"bd4443e6-1eef-43f3-9886-25fc9ceeaae7\", \"datePublished\": \"2026-01-05T10:06:05.494Z\", \"assignerShortName\": \"Centreon\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…