CVE-2025-5090 (GCVE-0-2025-5090)

Vulnerability from cvelistv5 – Published: 2026-06-05 15:49 – Updated: 2026-06-05 15:49
VLAI
Title
Arista CloudVision Exchange Cluster Instability via Unexpected Switch Messages
Summary
CVX is not resilient to unexpected messages from a connected switch. This leads to agent crashes on CVX causing instability in the CVX cluster. An attacker could use this behavior to create a denial of service (DoS) scenario. Note that this would require the attacker to have a high privilege access to the connected switch to be able to send custom TCP packets to the CVX.
CWE
  • CWE-20 - Improper Input Validation
Assigner
References
Impacted products
Vendor Product Version
Arista Networks EOS / CloudVision eXchange (CVX) Affected: 4.34.0F , ≤ 4.34.1F (custom)
Affected: 4.33.0M , ≤ 4.33.4M (custom)
Affected: 4.32.0M , ≤ 4.32.6M (custom)
Affected: 4.31.0 , < 4.32.0 (custom)
Affected: 4.30.0 , < 4.31.0 (custom)
Create a notification for this product.
Date Public
2025-11-18 16:46
Show details on NVD website

{
  "containers": {
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "CloudVision eXchange",
            "virtual or physical appliance"
          ],
          "product": "EOS / CloudVision eXchange (CVX)",
          "vendor": "Arista Networks",
          "versions": [
            {
              "lessThanOrEqual": "4.34.1F",
              "status": "affected",
              "version": "4.34.0F",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "4.33.4M",
              "status": "affected",
              "version": "4.33.0M",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "4.32.6M",
              "status": "affected",
              "version": "4.32.0M",
              "versionType": "custom"
            },
            {
              "lessThan": "4.32.0",
              "status": "affected",
              "version": "4.31.0",
              "versionType": "custom"
            },
            {
              "lessThan": "4.31.0",
              "status": "affected",
              "version": "4.30.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "configurations": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eIn order to be vulnerable to CVE-2025-5090, the following condition must be met: CVX must be configured:\u003c/p\u003e\n\u003cpre\u003e\u003ccode\u003ecvx1#show cvx\n  Status: Enabled\n  Mode: Standalone\n  Heartbeat interval: 20.0\n  Heartbeat timeout: 60.0\n  Client connection state preserving: Disabled\n  \ncvx1#show running-config section cvx\ncvx\n   no shutdown\u003c/code\u003e\u003c/pre\u003e"
            }
          ],
          "value": "In order to be vulnerable to CVE-2025-5090, the following condition must be met: CVX must be configured:\n\n\n\n\ncvx1#show cvx\n  Status: Enabled\n  Mode: Standalone\n  Heartbeat interval: 20.0\n  Heartbeat timeout: 60.0\n  Client connection state preserving: Disabled\n  \ncvx1#show running-config section cvx\ncvx\n   no shutdown"
        }
      ],
      "datePublic": "2025-11-18T16:46:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eCVX is not resilient to unexpected messages from a connected switch. This leads to agent crashes on CVX causing instability in the CVX cluster. An attacker could use this behavior to create a denial of service (DoS) scenario. Note that this would require the attacker to have a high privilege access to the connected switch to be able to send custom TCP packets to the CVX.\u003c/p\u003e"
            }
          ],
          "value": "CVX is not resilient to unexpected messages from a connected switch. This leads to agent crashes on CVX causing instability in the CVX cluster. An attacker could use this behavior to create a denial of service (DoS) scenario. Note that this would require the attacker to have a high privilege access to the connected switch to be able to send custom TCP packets to the CVX."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20: Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-05T15:49:27.770Z",
        "orgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
        "shortName": "Arista"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.arista.com/en/support/advisories-notices/security-advisory/22868-security-advisory-0126"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eThe recommended resolution is to upgrade to a remediated software version at your earliest convenience. CVE-2025-5090 has been fixed in the following releases:\u003c/p\u003e\n\u003cul\u003e\n  \u003cli\u003e4.34.2F and later releases in the 4.34.x train\u003c/li\u003e\n  \u003cli\u003e4.33.5M and later releases in the 4.33.x train\u003c/li\u003e\n  \u003cli\u003e4.32.7M and later releases in the 4.32.x train\u003c/li\u003e\n\u003c/ul\u003e"
            }
          ],
          "value": "The recommended resolution is to upgrade to a remediated software version at your earliest convenience. CVE-2025-5090 has been fixed in the following releases:\n\n\n\n    *  4.34.2F and later releases in the 4.34.x train\n\n    *  4.33.5M and later releases in the 4.33.x train\n\n    *  4.32.7M and later releases in the 4.32.x train"
        }
      ],
      "source": {
        "advisory": "0126",
        "defect": [
          "BUG1139764"
        ],
        "discovery": "INTERNAL"
      },
      "title": "Arista CloudVision Exchange Cluster Instability via Unexpected Switch Messages",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eThere is no mitigation for this issue.\u003c/p\u003e"
            }
          ],
          "value": "There is no mitigation for this issue."
        }
      ],
      "x_capecAlignment": {
        "capecId": "CAPEC-125",
        "capecName": "Flooding / Malformed Packet",
        "justification": "An attacker with high privilege access over a downstream switch can emit unexpected or malformed TCP packets causing state management code on CVX (ControllerOob/Controllerdb) to throw unhandled faults, leading to ongoing client deregistration cycles and cluster instability."
      },
      "x_generator": {
        "engine": "Vulnogram"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
    "assignerShortName": "Arista",
    "cveId": "CVE-2025-5090",
    "datePublished": "2026-06-05T15:49:27.770Z",
    "dateReserved": "2025-05-22T16:26:48.444Z",
    "dateUpdated": "2026-06-05T15:49:27.770Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2025-5090",
      "date": "2026-06-08",
      "epss": "0.00044",
      "percentile": "0.13764"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-5090\",\"sourceIdentifier\":\"psirt@arista.com\",\"published\":\"2026-06-05T17:16:30.347\",\"lastModified\":\"2026-06-05T19:03:48.933\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"CVX is not resilient to unexpected messages from a connected switch. This leads to agent crashes on CVX causing instability in the CVX cluster. An attacker could use this behavior to create a denial of service (DoS) scenario. Note that this would require the attacker to have a high privilege access to the connected switch to be able to send custom TCP packets to the CVX.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"psirt@arista.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":7.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"NONE\",\"vulnIntegrityImpact\":\"NONE\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"psirt@arista.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"psirt@arista.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]}],\"references\":[{\"url\":\"https://www.arista.com/en/support/advisories-notices/security-advisory/22868-security-advisory-0126\",\"source\":\"psirt@arista.com\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…