GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2025-23237 (GCVE-0-2025-23237)

Vulnerability from cvelistv5 – Published: 2025-01-22 05:50 – Updated: 2025-02-12 20:41
VLAI
Summary
Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in UD-LT2 firmware Ver.1.00.008_SE and earlier. If a user logs in to CLI of the affected product, an arbitrary OS command may be executed.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-01-22 14:33 UTC
CWE
  • CWE-78 - Improper neutralization of special elements used in an OS command ('OS Command Injection')
Impacted products
Vendor Product Version CPE status
I-O DATA DEVICE, INC. UD-LT2 Affected: firmware Ver.1.00.008_SE and earlier
guessed Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-23237",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-22T14:33:28.348307Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-12T20:41:22.887Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "UD-LT2",
          "vendor": "I-O DATA DEVICE, INC.",
          "versions": [
            {
              "status": "affected",
              "version": "firmware Ver.1.00.008_SE and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper neutralization of special elements used in an OS command (\u0027OS Command Injection\u0027) issue exists in UD-LT2 firmware Ver.1.00.008_SE and earlier. If a user logs in to CLI of the affected product, an arbitrary OS command may be executed."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 6.6,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "Improper neutralization of special elements used in an OS command (\u0027OS Command Injection\u0027)",
              "lang": "en-US",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-01-22T05:50:14.930Z",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "url": "https://www.iodata.jp/support/information/2025/01_ud-lt2/"
        },
        {
          "url": "https://jvn.jp/en/jp/JVN15293958/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2025-23237",
    "datePublished": "2025-01-22T05:50:14.930Z",
    "dateReserved": "2025-01-16T07:05:52.884Z",
    "dateUpdated": "2025-02-12T20:41:22.887Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2025-23237",
      "date": "2026-09-17",
      "epss": "0.009",
      "percentile": "0.57987"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-23237\",\"sourceIdentifier\":\"vultures@jpcert.or.jp\",\"published\":\"2025-01-22T06:15:14.480\",\"lastModified\":\"2026-06-17T08:52:49.380\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Improper neutralization of special elements used in an OS command (\u0027OS Command Injection\u0027) issue exists in UD-LT2 firmware Ver.1.00.008_SE and earlier. If a user logs in to CLI of the affected product, an arbitrary OS command may be executed.\"},{\"lang\":\"es\",\"value\":\"Existe un problema de neutralizaci\u00f3n incorrecta de elementos especiales utilizados en un comando del SO (\u0027Inyecci\u00f3n de comando del SO\u0027) en el firmware UD-LT2 Ver.1.00.008_SE y anteriores. Si un usuario inicia sesi\u00f3n en la CLI del producto afectado, se puede ejecutar un comando arbitrario del SO.\"}],\"affected\":[{\"source\":\"vultures@jpcert.or.jp\",\"affectedData\":[{\"vendor\":\"I-O DATA DEVICE, INC.\",\"product\":\"UD-LT2\",\"versions\":[{\"version\":\"firmware Ver.1.00.008_SE and earlier\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"vultures@jpcert.or.jp\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":6.6,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.7,\"impactScore\":5.9}],\"ssvcV203\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"ssvcData\":{\"timestamp\":\"2025-01-22T14:33:28.348307Z\",\"id\":\"CVE-2025-23237\",\"options\":[{\"exploitation\":\"none\"},{\"automatable\":\"no\"},{\"technicalImpact\":\"total\"}],\"role\":\"CISA Coordinator\",\"version\":\"2.0.3\"}}]},\"weaknesses\":[{\"source\":\"vultures@jpcert.or.jp\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"references\":[{\"url\":\"https://jvn.jp/en/jp/JVN15293958/\",\"source\":\"vultures@jpcert.or.jp\"},{\"url\":\"https://www.iodata.jp/support/information/2025/01_ud-lt2/\",\"source\":\"vultures@jpcert.or.jp\"}]}}",
    "vulnrichment": {
      "containers": "{\"cna\": {\"affected\": [{\"vendor\": \"I-O DATA DEVICE, INC.\", \"product\": \"UD-LT2\", \"versions\": [{\"version\": \"firmware Ver.1.00.008_SE and earlier\", \"status\": \"affected\"}]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"Improper neutralization of special elements used in an OS command (\u0027OS Command Injection\u0027) issue exists in UD-LT2 firmware Ver.1.00.008_SE and earlier. If a user logs in to CLI of the affected product, an arbitrary OS command may be executed.\"}], \"problemTypes\": [{\"descriptions\": [{\"description\": \"Improper neutralization of special elements used in an OS command (\u0027OS Command Injection\u0027)\", \"lang\": \"en-US\", \"cweId\": \"CWE-78\", \"type\": \"CWE\"}]}], \"references\": [{\"url\": \"https://www.iodata.jp/support/information/2025/01_ud-lt2/\"}, {\"url\": \"https://jvn.jp/en/jp/JVN15293958/\"}], \"metrics\": [{\"format\": \"CVSS\", \"scenarios\": [{\"lang\": \"en-US\", \"value\": \"GENERAL\"}], \"cvssV3_0\": {\"version\": \"3.0\", \"baseSeverity\": \"MEDIUM\", \"baseScore\": 6.6, \"vectorString\": \"CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H\"}}], \"providerMetadata\": {\"orgId\": \"ede6fdc4-6654-4307-a26d-3331c018e2ce\", \"shortName\": \"jpcert\", \"dateUpdated\": \"2025-01-22T05:50:14.930Z\"}}, \"adp\": [{\"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-23237\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-01-22T14:33:28.348307Z\"}}}], \"providerMetadata\": {\"shortName\": \"CISA-ADP\", \"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"dateUpdated\": \"2025-02-12T20:33:27.045Z\"}, \"title\": \"CISA ADP Vulnrichment\"}]}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-23237\", \"assignerOrgId\": \"ede6fdc4-6654-4307-a26d-3331c018e2ce\", \"state\": \"PUBLISHED\", \"assignerShortName\": \"jpcert\", \"dateReserved\": \"2025-01-16T07:05:52.884Z\", \"datePublished\": \"2025-01-22T05:50:14.930Z\", \"dateUpdated\": \"2025-01-22T05:50:14.930Z\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…