cve-2025-1449
Vulnerability from cvelistv5
Published
2025-03-31 16:00
Modified
2025-03-31 18:24
Summary
A vulnerability exists in the Rockwell Automation Verve Asset Manager due to insufficient variable sanitizing. A portion of the administrative web interface for Verve's Legacy Agentless Device Inventory (ADI) capability (deprecated since the 1.36 release) allows users to change a variable with inadequate sanitizing. If exploited, it could allow a threat actor with administrative access to run arbitrary commands in the context of the container running the service.
Impacted products
Show details on NVD website


{
   containers: {
      adp: [
         {
            metrics: [
               {
                  other: {
                     content: {
                        id: "CVE-2025-1449",
                        options: [
                           {
                              Exploitation: "none",
                           },
                           {
                              Automatable: "no",
                           },
                           {
                              "Technical Impact": "total",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2025-03-31T17:53:19.410844Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            providerMetadata: {
               dateUpdated: "2025-03-31T18:24:38.780Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
      ],
      cna: {
         affected: [
            {
               defaultStatus: "unaffected",
               product: "Verve Asset Manager",
               vendor: "Rockwell Automation",
               versions: [
                  {
                     status: "affected",
                     version: "<=1.39",
                  },
               ],
            },
         ],
         datePublic: "2025-03-20T13:00:00.000Z",
         descriptions: [
            {
               lang: "en",
               supportingMedia: [
                  {
                     base64: false,
                     type: "text/html",
                     value: "<span style=\"background-color: rgb(255, 255, 255);\">A vulnerability exists in the Rockwell Automation Verve Asset Manager due to insufficient variable sanitizing. A portion of the administrative web interface for Verve's Legacy Agentless Device Inventory (ADI) capability (deprecated since the 1.36 release) allows users to change a variable with inadequate sanitizing. If exploited, it could allow a threat actor with administrative access to run arbitrary commands in the context of the container running the service. </span>",
                  },
               ],
               value: "A vulnerability exists in the Rockwell Automation Verve Asset Manager due to insufficient variable sanitizing. A portion of the administrative web interface for Verve's Legacy Agentless Device Inventory (ADI) capability (deprecated since the 1.36 release) allows users to change a variable with inadequate sanitizing. If exploited, it could allow a threat actor with administrative access to run arbitrary commands in the context of the container running the service.",
            },
         ],
         metrics: [
            {
               cvssV4_0: {
                  Automatable: "NOT_DEFINED",
                  Recovery: "NOT_DEFINED",
                  Safety: "NOT_DEFINED",
                  attackComplexity: "LOW",
                  attackRequirements: "PRESENT",
                  attackVector: "NETWORK",
                  baseScore: 7.5,
                  baseSeverity: "HIGH",
                  privilegesRequired: "HIGH",
                  providerUrgency: "NOT_DEFINED",
                  subAvailabilityImpact: "NONE",
                  subConfidentialityImpact: "NONE",
                  subIntegrityImpact: "NONE",
                  userInteraction: "NONE",
                  valueDensity: "NOT_DEFINED",
                  vectorString: "CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                  version: "4.0",
                  vulnAvailabilityImpact: "HIGH",
                  vulnConfidentialityImpact: "HIGH",
                  vulnIntegrityImpact: "HIGH",
                  vulnerabilityResponseEffort: "NOT_DEFINED",
               },
               format: "CVSS",
               scenarios: [
                  {
                     lang: "en",
                     value: "GENERAL",
                  },
               ],
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "CWE -1287 Improper Validation of Specified Type of Input",
                     lang: "en",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2025-03-31T16:00:56.951Z",
            orgId: "b73dd486-f505-4403-b634-40b078b177f0",
            shortName: "Rockwell",
         },
         references: [
            {
               url: "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1723.html",
            },
         ],
         solutions: [
            {
               lang: "en",
               supportingMedia: [
                  {
                     base64: false,
                     type: "text/html",
                     value: "<table><tbody><tr><td><p>Affected Product&nbsp;</p></td><td><p>&nbsp;</p><p>&nbsp;</p><p>Affected Version(s)</p><p>&nbsp;</p><p>&nbsp;</p></td><td><p>&nbsp;</p><p>&nbsp;</p><p>Corrected in Software Revision </p><p>&nbsp;</p><p>&nbsp;</p></td></tr><tr><td><p>&nbsp;</p><p>&nbsp;</p><p>Verve Asset Manager </p><p>&nbsp;</p><p>&nbsp;</p></td><td><p>&nbsp;</p><p>&nbsp;</p><p>&lt;=1.39</p><p>&nbsp;</p><p>&nbsp;</p></td><td><p>V1.40</p></td></tr></tbody></table>\n\n<br>",
                  },
               ],
               value: "Affected Product \n\n \n\n \n\nAffected Version(s)\n\n \n\n \n\n \n\n \n\nCorrected in Software Revision \n\n \n\n \n\n \n\n \n\nVerve Asset Manager \n\n \n\n \n\n \n\n \n\n<=1.39\n\n \n\n \n\nV1.40",
            },
         ],
         source: {
            advisory: "SD1723",
            discovery: "INTERNAL",
         },
         title: "Admin Shell Access Vulnerability in Rockwell Automation Verve Asset Manager",
         x_generator: {
            engine: "Vulnogram 0.2.0",
         },
      },
   },
   cveMetadata: {
      assignerOrgId: "b73dd486-f505-4403-b634-40b078b177f0",
      assignerShortName: "Rockwell",
      cveId: "CVE-2025-1449",
      datePublished: "2025-03-31T16:00:56.951Z",
      dateReserved: "2025-02-18T16:22:18.886Z",
      dateUpdated: "2025-03-31T18:24:38.780Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
   "vulnerability-lookup:meta": {
      nvd: "{\"cve\":{\"id\":\"CVE-2025-1449\",\"sourceIdentifier\":\"PSIRT@rockwellautomation.com\",\"published\":\"2025-03-31T16:15:22.770\",\"lastModified\":\"2025-04-01T20:26:22.890\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability exists in the Rockwell Automation Verve Asset Manager due to insufficient variable sanitizing. A portion of the administrative web interface for Verve's Legacy Agentless Device Inventory (ADI) capability (deprecated since the 1.36 release) allows users to change a variable with inadequate sanitizing. If exploited, it could allow a threat actor with administrative access to run arbitrary commands in the context of the container running the service.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"PRESENT\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}]},\"references\":[{\"url\":\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1723.html\",\"source\":\"PSIRT@rockwellautomation.com\"}]}}",
      vulnrichment: {
         containers: "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-1449\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-03-31T17:53:19.410844Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-03-31T17:53:24.841Z\"}}], \"cna\": {\"title\": \"Admin Shell Access Vulnerability in Rockwell Automation Verve Asset Manager\", \"source\": {\"advisory\": \"SD1723\", \"discovery\": \"INTERNAL\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 7.5, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"PRESENT\", \"privilegesRequired\": \"HIGH\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Rockwell Automation\", \"product\": \"Verve Asset Manager\", \"versions\": [{\"status\": \"affected\", \"version\": \"<=1.39\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Affected Product\\u00a0\\n\\n\\u00a0\\n\\n\\u00a0\\n\\nAffected Version(s)\\n\\n\\u00a0\\n\\n\\u00a0\\n\\n\\u00a0\\n\\n\\u00a0\\n\\nCorrected in Software Revision \\n\\n\\u00a0\\n\\n\\u00a0\\n\\n\\u00a0\\n\\n\\u00a0\\n\\nVerve Asset Manager \\n\\n\\u00a0\\n\\n\\u00a0\\n\\n\\u00a0\\n\\n\\u00a0\\n\\n<=1.39\\n\\n\\u00a0\\n\\n\\u00a0\\n\\nV1.40\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"<table><tbody><tr><td><p>Affected Product&nbsp;</p></td><td><p>&nbsp;</p><p>&nbsp;</p><p>Affected Version(s)</p><p>&nbsp;</p><p>&nbsp;</p></td><td><p>&nbsp;</p><p>&nbsp;</p><p>Corrected in Software Revision </p><p>&nbsp;</p><p>&nbsp;</p></td></tr><tr><td><p>&nbsp;</p><p>&nbsp;</p><p>Verve Asset Manager </p><p>&nbsp;</p><p>&nbsp;</p></td><td><p>&nbsp;</p><p>&nbsp;</p><p>&lt;=1.39</p><p>&nbsp;</p><p>&nbsp;</p></td><td><p>V1.40</p></td></tr></tbody></table>\\n\\n<br>\", \"base64\": false}]}], \"datePublic\": \"2025-03-20T13:00:00.000Z\", \"references\": [{\"url\": \"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1723.html\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability exists in the Rockwell Automation Verve Asset Manager due to insufficient variable sanitizing. A portion of the administrative web interface for Verve's Legacy Agentless Device Inventory (ADI) capability (deprecated since the 1.36 release) allows users to change a variable with inadequate sanitizing. If exploited, it could allow a threat actor with administrative access to run arbitrary commands in the context of the container running the service.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"<span style=\\\"background-color: rgb(255, 255, 255);\\\">A vulnerability exists in the Rockwell Automation Verve Asset Manager due to insufficient variable sanitizing. A portion of the administrative web interface for Verve's Legacy Agentless Device Inventory (ADI) capability (deprecated since the 1.36 release) allows users to change a variable with inadequate sanitizing. If exploited, it could allow a threat actor with administrative access to run arbitrary commands in the context of the container running the service. </span>\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"description\": \"CWE -1287 Improper Validation of Specified Type of Input\"}]}], \"providerMetadata\": {\"orgId\": \"b73dd486-f505-4403-b634-40b078b177f0\", \"shortName\": \"Rockwell\", \"dateUpdated\": \"2025-03-31T16:00:56.951Z\"}}}",
         cveMetadata: "{\"cveId\": \"CVE-2025-1449\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-03-31T18:24:38.780Z\", \"dateReserved\": \"2025-02-18T16:22:18.886Z\", \"assignerOrgId\": \"b73dd486-f505-4403-b634-40b078b177f0\", \"datePublished\": \"2025-03-31T16:00:56.951Z\", \"assignerShortName\": \"Rockwell\"}",
         dataType: "CVE_RECORD",
         dataVersion: "5.1",
      },
   },
}


Log in or create an account to share your comment.

Security Advisory comment format.

This schema specifies the format of a comment related to a security advisory.

UUIDv4 of the comment
UUIDv4 of the Vulnerability-Lookup instance
When the comment was created originally
When the comment was last updated
Title of the comment
Description of the comment
The identifier of the vulnerability (CVE ID, GHSA-ID, PYSEC ID, etc.).



Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.