CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become unresponsive resulting in communication loss when a large amount of IGMP packets is present in the network.
Impacted products
Show details on NVD website


{
   containers: {
      adp: [
         {
            affected: [
               {
                  cpes: [
                     "cpe:2.3:h:schneider-electric:powerlogic_pm5320:*:*:*:*:*:*:*:*",
                  ],
                  defaultStatus: "unknown",
                  product: "powerlogic_pm5320",
                  vendor: "schneider-electric",
                  versions: [
                     {
                        lessThanOrEqual: "2.3.8",
                        status: "affected",
                        version: "0",
                        versionType: "custom",
                     },
                  ],
               },
               {
                  cpes: [
                     "cpe:2.3:h:schneider-electric:powerlogic_pm5340:*:*:*:*:*:*:*:*",
                  ],
                  defaultStatus: "unknown",
                  product: "powerlogic_pm5340",
                  vendor: "schneider-electric",
                  versions: [
                     {
                        lessThanOrEqual: "2.3.8",
                        status: "affected",
                        version: "0",
                        versionType: "custom",
                     },
                  ],
               },
               {
                  cpes: [
                     "cpe:2.3:h:schneider-electric:powerlogic_pm5341:*:*:*:*:*:*:*:*",
                  ],
                  defaultStatus: "unknown",
                  product: "powerlogic_pm5341",
                  vendor: "schneider-electric",
                  versions: [
                     {
                        lessThanOrEqual: "2.6.6",
                        status: "affected",
                        version: "0",
                        versionType: "custom",
                     },
                  ],
               },
            ],
            metrics: [
               {
                  other: {
                     content: {
                        id: "CVE-2024-9409",
                        options: [
                           {
                              Exploitation: "none",
                           },
                           {
                              Automatable: "yes",
                           },
                           {
                              "Technical Impact": "partial",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2024-11-13T14:40:24.630364Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            providerMetadata: {
               dateUpdated: "2024-11-13T14:43:17.912Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
      ],
      cna: {
         affected: [
            {
               defaultStatus: "unaffected",
               product: "PowerLogic PM5320",
               vendor: "Schneider Electric",
               versions: [
                  {
                     status: "affected",
                     version: "Version 2.3.8 and prior",
                  },
               ],
            },
            {
               defaultStatus: "unaffected",
               product: "PowerLogic PM5340",
               vendor: "Schneider Electric",
               versions: [
                  {
                     status: "affected",
                     version: "Version 2.3.8 and prior",
                  },
               ],
            },
            {
               defaultStatus: "unaffected",
               product: "PowerLogic PM5341",
               vendor: "Schneider Electric",
               versions: [
                  {
                     status: "affected",
                     version: "Version 2.6.6 and prior",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               supportingMedia: [
                  {
                     base64: false,
                     type: "text/html",
                     value: "CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become\nunresponsive resulting in communication loss when a large amount of IGMP packets is present in the network.\n\n<br>",
                  },
               ],
               value: "CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become\nunresponsive resulting in communication loss when a large amount of IGMP packets is present in the network.",
            },
         ],
         metrics: [
            {
               cvssV4_0: {
                  Automatable: "NOT_DEFINED",
                  Recovery: "NOT_DEFINED",
                  Safety: "NOT_DEFINED",
                  attackComplexity: "LOW",
                  attackRequirements: "NONE",
                  attackVector: "NETWORK",
                  baseScore: 8.7,
                  baseSeverity: "HIGH",
                  privilegesRequired: "NONE",
                  providerUrgency: "NOT_DEFINED",
                  subAvailabilityImpact: "NONE",
                  subConfidentialityImpact: "NONE",
                  subIntegrityImpact: "NONE",
                  userInteraction: "NONE",
                  valueDensity: "NOT_DEFINED",
                  vectorString: "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                  version: "4.0",
                  vulnAvailabilityImpact: "HIGH",
                  vulnConfidentialityImpact: "NONE",
                  vulnIntegrityImpact: "NONE",
                  vulnerabilityResponseEffort: "NOT_DEFINED",
               },
               format: "CVSS",
               scenarios: [
                  {
                     lang: "en",
                     value: "GENERAL",
                  },
               ],
            },
            {
               cvssV3_1: {
                  attackComplexity: "LOW",
                  attackVector: "NETWORK",
                  availabilityImpact: "HIGH",
                  baseScore: 7.5,
                  baseSeverity: "HIGH",
                  confidentialityImpact: "NONE",
                  integrityImpact: "NONE",
                  privilegesRequired: "NONE",
                  scope: "UNCHANGED",
                  userInteraction: "NONE",
                  vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  version: "3.1",
               },
               format: "CVSS",
               scenarios: [
                  {
                     lang: "en",
                     value: "GENERAL",
                  },
               ],
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     cweId: "CWE-400",
                     description: "CWE-400 Uncontrolled Resource Consumption",
                     lang: "en",
                     type: "CWE",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2024-11-13T04:29:01.040Z",
            orgId: "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            shortName: "schneider",
         },
         references: [
            {
               url: "https://download.schneider-electric.com/doc/SEVD-2024-317-01/SEVD-2024-317-01.pdf",
            },
         ],
         source: {
            discovery: "UNKNOWN",
         },
         x_generator: {
            engine: "Vulnogram 0.2.0",
         },
      },
   },
   cveMetadata: {
      assignerOrgId: "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
      assignerShortName: "schneider",
      cveId: "CVE-2024-9409",
      datePublished: "2024-11-13T04:29:01.040Z",
      dateReserved: "2024-10-01T12:08:25.066Z",
      dateUpdated: "2024-11-13T14:43:17.912Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
   "vulnerability-lookup:meta": {
      nvd: "{\"cve\":{\"id\":\"CVE-2024-9409\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2024-11-13T05:15:27.610\",\"lastModified\":\"2024-11-19T15:59:21.690\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become\\nunresponsive resulting in communication loss when a large amount of IGMP packets is present in the network.\"},{\"lang\":\"es\",\"value\":\"CWE-400: Existe una vulnerabilidad de consumo descontrolado de recursos que podría provocar que el dispositivo deje de responder y produzca pérdida de comunicación cuando hay una gran cantidad de paquetes IGMP en la red.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":8.7,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnerableSystemConfidentiality\":\"NONE\",\"vulnerableSystemIntegrity\":\"NONE\",\"vulnerableSystemAvailability\":\"HIGH\",\"subsequentSystemConfidentiality\":\"NONE\",\"subsequentSystemIntegrity\":\"NONE\",\"subsequentSystemAvailability\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirements\":\"NOT_DEFINED\",\"integrityRequirements\":\"NOT_DEFINED\",\"availabilityRequirements\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnerableSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedVulnerableSystemIntegrity\":\"NOT_DEFINED\",\"modifiedVulnerableSystemAvailability\":\"NOT_DEFINED\",\"modifiedSubsequentSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedSubsequentSystemIntegrity\":\"NOT_DEFINED\",\"modifiedSubsequentSystemAvailability\":\"NOT_DEFINED\",\"safety\":\"NOT_DEFINED\",\"automatable\":\"NOT_DEFINED\",\"recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-400\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_pm5341_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.7.0\",\"matchCriteriaId\":\"2C518E91-E251-4278-83D6-144B1CC6331F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_pm5341:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9C575247-0AE3-408C-8154-71A256FD0292\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_pm5340_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.4.0\",\"matchCriteriaId\":\"65E456CF-4247-4FB9-858D-6920EF946CF2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_pm5340:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F5C8EA2A-37CF-435F-A1ED-789255404CD6\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_pm5320_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.4.0\",\"matchCriteriaId\":\"EB64AE9B-637D-48A5-AE98-6F120C7E355A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_pm5320:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"47592B0C-9E15-4D4C-B284-F2390678E1AC\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/doc/SEVD-2024-317-01/SEVD-2024-317-01.pdf\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Mitigation\",\"Patch\",\"Vendor Advisory\"]}]}}",
      vulnrichment: {
         containers: "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-9409\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-11-13T14:40:24.630364Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:h:schneider-electric:powerlogic_pm5320:*:*:*:*:*:*:*:*\"], \"vendor\": \"schneider-electric\", \"product\": \"powerlogic_pm5320\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"2.3.8\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:h:schneider-electric:powerlogic_pm5340:*:*:*:*:*:*:*:*\"], \"vendor\": \"schneider-electric\", \"product\": \"powerlogic_pm5340\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"2.3.8\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:h:schneider-electric:powerlogic_pm5341:*:*:*:*:*:*:*:*\"], \"vendor\": \"schneider-electric\", \"product\": \"powerlogic_pm5341\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"2.6.6\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-11-13T14:43:06.004Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 8.7, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"NONE\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"NONE\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}, {\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Schneider Electric\", \"product\": \"PowerLogic PM5320\", \"versions\": [{\"status\": \"affected\", \"version\": \"Version 2.3.8 and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"PowerLogic PM5340\", \"versions\": [{\"status\": \"affected\", \"version\": \"Version 2.3.8 and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"PowerLogic PM5341\", \"versions\": [{\"status\": \"affected\", \"version\": \"Version 2.6.6 and prior\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://download.schneider-electric.com/doc/SEVD-2024-317-01/SEVD-2024-317-01.pdf\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become\\nunresponsive resulting in communication loss when a large amount of IGMP packets is present in the network.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become\\nunresponsive resulting in communication loss when a large amount of IGMP packets is present in the network.\\n\\n<br>\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-400\", \"description\": \"CWE-400 Uncontrolled Resource Consumption\"}]}], \"providerMetadata\": {\"orgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"shortName\": \"schneider\", \"dateUpdated\": \"2024-11-13T04:29:01.040Z\"}}}",
         cveMetadata: "{\"cveId\": \"CVE-2024-9409\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-11-13T14:43:17.912Z\", \"dateReserved\": \"2024-10-01T12:08:25.066Z\", \"assignerOrgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"datePublished\": \"2024-11-13T04:29:01.040Z\", \"assignerShortName\": \"schneider\"}",
         dataType: "CVE_RECORD",
         dataVersion: "5.1",
      },
   },
}


Log in or create an account to share your comment.

Security Advisory comment format.

This schema specifies the format of a comment related to a security advisory.

UUIDv4 of the comment
UUIDv4 of the Vulnerability-Lookup instance
When the comment was created originally
When the comment was last updated
Title of the comment
Description of the comment
The identifier of the vulnerability (CVE ID, GHSA-ID, PYSEC ID, etc.).



Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.