CVE-2024-6089 (GCVE-0-2024-6089)
Vulnerability from cvelistv5 – Published: 2024-07-16 17:10 – Updated: 2024-08-01 21:33
VLAI?
Title
Rockwell Automation Major nonrecoverable fault in 5015 – AENFTXT
Summary
An input validation vulnerability exists in the Rockwell Automation 5015 - AENFTXT when a manipulated PTP packet is sent, causing the secondary adapter to result in a major nonrecoverable fault. If exploited, a power cycle is required to recover the product.
Severity ?
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Rockwell Automation | 5015 - AENFTXT |
Affected:
v2.011
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:rockwellautomation:5015_aenftxt:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "5015_aenftxt",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "v2.011"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-6089",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-17T14:54:24.869257Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-17T14:57:56.133Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T21:33:04.327Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1680.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "5015 - AENFTXT",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "v2.011"
}
]
}
],
"datePublic": "2024-07-16T13:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn input validation vulnerability exists in the Rockwell Automation\u0026nbsp;5015 - AENFTXT\u0026nbsp;when a manipulated PTP packet is sent, causing the secondary adapter to result in a major nonrecoverable fault. If exploited, a power cycle is required to recover the product. \u0026nbsp;\u003c/span\u003e\n\n"
}
],
"value": "An input validation vulnerability exists in the Rockwell Automation\u00a05015 - AENFTXT\u00a0when a manipulated PTP packet is sent, causing the secondary adapter to result in a major nonrecoverable fault. If exploited, a power cycle is required to recover the product."
}
],
"impacts": [
{
"capecId": "CAPEC-153",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-153 Input Data Manipulation"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-16T17:10:21.810Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1680.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cp\u003eCustomers using the affected software are encouraged to apply the risk mitigations, if possible.\u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003eUpdate to the corrected firmware revision, v2.012.\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003eFor information on how to mitigate Security Risks on industrial automation control systems, we encourage customers to implement our suggested \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003esecurity best practices\u003c/a\u003e\u0026nbsp;to minimize the risk of the vulnerability.\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Customers using the affected software are encouraged to apply the risk mitigations, if possible.\n\n * Update to the corrected firmware revision, v2.012.\n\n\n\n\n * For information on how to mitigate Security Risks on industrial automation control systems, we encourage customers to implement our suggested security best practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight \u00a0to minimize the risk of the vulnerability."
}
],
"source": {
"advisory": "SD1680",
"discovery": "INTERNAL"
},
"title": "Rockwell Automation Major nonrecoverable fault in 5015 \u2013 AENFTXT",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2024-6089",
"datePublished": "2024-07-16T17:10:21.810Z",
"dateReserved": "2024-06-17T18:12:51.583Z",
"dateUpdated": "2024-08-01T21:33:04.327Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:rockwellautomation:5015-aenftxt_firmware:2.011:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"436F7BB7-A8CA-4E00-9F42-6DDB0D995E09\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:rockwellautomation:5015-aenftxt:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C699B471-D2E4-4B2F-B0A4-6045B8170354\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"An input validation vulnerability exists in the Rockwell Automation\\u00a05015 - AENFTXT\\u00a0when a manipulated PTP packet is sent, causing the secondary adapter to result in a major nonrecoverable fault. If exploited, a power cycle is required to recover the product.\"}, {\"lang\": \"es\", \"value\": \"Existe una vulnerabilidad de validaci\\u00f3n de entrada en Rockwell Automation 5015 - AENFTXT cuando se env\\u00eda un paquete PTP manipulado, lo que provoca que el adaptador secundario genere una falla importante no recuperable. Si se explota, se requiere un ciclo de energ\\u00eda para recuperar el producto.\"}]",
"id": "CVE-2024-6089",
"lastModified": "2024-11-21T09:48:56.433",
"metrics": "{\"cvssMetricV40\": [{\"source\": \"PSIRT@rockwellautomation.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"4.0\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\", \"baseScore\": 8.7, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"vulnerableSystemConfidentiality\": \"HIGH\", \"vulnerableSystemIntegrity\": \"NONE\", \"vulnerableSystemAvailability\": \"NONE\", \"subsequentSystemConfidentiality\": \"NONE\", \"subsequentSystemIntegrity\": \"NONE\", \"subsequentSystemAvailability\": \"NONE\", \"exploitMaturity\": \"NOT_DEFINED\", \"confidentialityRequirements\": \"NOT_DEFINED\", \"integrityRequirements\": \"NOT_DEFINED\", \"availabilityRequirements\": \"NOT_DEFINED\", \"modifiedAttackVector\": \"NOT_DEFINED\", \"modifiedAttackComplexity\": \"NOT_DEFINED\", \"modifiedAttackRequirements\": \"NOT_DEFINED\", \"modifiedPrivilegesRequired\": \"NOT_DEFINED\", \"modifiedUserInteraction\": \"NOT_DEFINED\", \"modifiedVulnerableSystemConfidentiality\": \"NOT_DEFINED\", \"modifiedVulnerableSystemIntegrity\": \"NOT_DEFINED\", \"modifiedVulnerableSystemAvailability\": \"NOT_DEFINED\", \"modifiedSubsequentSystemConfidentiality\": \"NOT_DEFINED\", \"modifiedSubsequentSystemIntegrity\": \"NOT_DEFINED\", \"modifiedSubsequentSystemAvailability\": \"NOT_DEFINED\", \"safety\": \"NOT_DEFINED\", \"automatable\": \"NOT_DEFINED\", \"recovery\": \"NOT_DEFINED\", \"valueDensity\": \"NOT_DEFINED\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\"}}], \"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}]}",
"published": "2024-07-16T17:15:11.817",
"references": "[{\"url\": \"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1680.html\", \"source\": \"PSIRT@rockwellautomation.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1680.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "PSIRT@rockwellautomation.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"PSIRT@rockwellautomation.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-20\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"NVD-CWE-noinfo\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2024-6089\",\"sourceIdentifier\":\"PSIRT@rockwellautomation.com\",\"published\":\"2024-07-16T17:15:11.817\",\"lastModified\":\"2024-11-21T09:48:56.433\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An input validation vulnerability exists in the Rockwell Automation\u00a05015 - AENFTXT\u00a0when a manipulated PTP packet is sent, causing the secondary adapter to result in a major nonrecoverable fault. If exploited, a power cycle is required to recover the product.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad de validaci\u00f3n de entrada en Rockwell Automation 5015 - AENFTXT cuando se env\u00eda un paquete PTP manipulado, lo que provoca que el adaptador secundario genere una falla importante no recuperable. Si se explota, se requiere un ciclo de energ\u00eda para recuperar el producto.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":8.7,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"NONE\",\"vulnAvailabilityImpact\":\"NONE\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:5015-aenftxt_firmware:2.011:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"436F7BB7-A8CA-4E00-9F42-6DDB0D995E09\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:5015-aenftxt:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C699B471-D2E4-4B2F-B0A4-6045B8170354\"}]}]}],\"references\":[{\"url\":\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1680.html\",\"source\":\"PSIRT@rockwellautomation.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1680.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1680.html\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-01T21:33:04.327Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-6089\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-07-17T14:54:24.869257Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:rockwellautomation:5015_aenftxt:*:*:*:*:*:*:*:*\"], \"vendor\": \"rockwellautomation\", \"product\": \"5015_aenftxt\", \"versions\": [{\"status\": \"affected\", \"version\": \"v2.011\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-07-17T14:57:48.014Z\"}}], \"cna\": {\"title\": \"Rockwell Automation Major nonrecoverable fault in 5015 \\u2013 AENFTXT\", \"source\": {\"advisory\": \"SD1680\", \"discovery\": \"INTERNAL\"}, \"impacts\": [{\"capecId\": \"CAPEC-153\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-153 Input Data Manipulation\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 8.7, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"NONE\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"NONE\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Rockwell Automation\", \"product\": \"5015 - AENFTXT\", \"versions\": [{\"status\": \"affected\", \"version\": \"v2.011\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Customers using the affected software are encouraged to apply the risk mitigations, if possible.\\n\\n * Update to the corrected firmware revision, v2.012.\\n\\n\\n\\n\\n * For information on how to mitigate Security Risks on industrial automation control systems, we encourage customers to implement our suggested security best practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight \\u00a0to minimize the risk of the vulnerability.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\n\u003cp\u003eCustomers using the affected software are encouraged to apply the risk mitigations, if possible.\u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003eUpdate to the corrected firmware revision, v2.012.\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003eFor information on how to mitigate Security Risks on industrial automation control systems, we encourage customers to implement our suggested \u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\\\"\u003esecurity best practices\u003c/a\u003e\u0026nbsp;to minimize the risk of the vulnerability.\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\", \"base64\": false}]}], \"datePublic\": \"2024-07-16T13:00:00.000Z\", \"references\": [{\"url\": \"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1680.html\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"An input validation vulnerability exists in the Rockwell Automation\\u00a05015 - AENFTXT\\u00a0when a manipulated PTP packet is sent, causing the secondary adapter to result in a major nonrecoverable fault. If exploited, a power cycle is required to recover the product.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\n\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003eAn input validation vulnerability exists in the Rockwell Automation\u0026nbsp;5015 - AENFTXT\u0026nbsp;when a manipulated PTP packet is sent, causing the secondary adapter to result in a major nonrecoverable fault. If exploited, a power cycle is required to recover the product. \u0026nbsp;\u003c/span\u003e\\n\\n\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-20\", \"description\": \"CWE-20: Improper Input Validation\"}]}], \"providerMetadata\": {\"orgId\": \"b73dd486-f505-4403-b634-40b078b177f0\", \"shortName\": \"Rockwell\", \"dateUpdated\": \"2024-07-16T17:10:21.810Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-6089\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-01T21:33:04.327Z\", \"dateReserved\": \"2024-06-17T18:12:51.583Z\", \"assignerOrgId\": \"b73dd486-f505-4403-b634-40b078b177f0\", \"datePublished\": \"2024-07-16T17:10:21.810Z\", \"assignerShortName\": \"Rockwell\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…