cve-2024-55593
Vulnerability from cvelistv5
Published
2025-01-14 14:08
Modified
2025-01-14 20:56
Summary
A improper neutralization of special elements used in an sql command ('sql injection') in Fortinet FortiWeb versions 6.3.17 through 7.6.1 allows attacker to gain information disclosure via crafted SQL queries
Impacted products
Vendor Product Version
Fortinet FortiWeb Version: 7.6.0    7.6.1
Version: 7.4.0    7.4.6
Version: 7.2.0    7.2.10
Version: 7.0.0    7.0.10
Version: 6.4.0    6.4.3
Version: 6.3.6    6.3.23
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-55593",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-14T15:15:29.839471Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-14T20:56:58.704Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [],
          "defaultStatus": "unaffected",
          "product": "FortiWeb",
          "vendor": "Fortinet",
          "versions": [
            {
              "lessThanOrEqual": "7.6.1",
              "status": "affected",
              "version": "7.6.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.4.6",
              "status": "affected",
              "version": "7.4.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.2.10",
              "status": "affected",
              "version": "7.2.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.0.10",
              "status": "affected",
              "version": "7.0.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "6.4.3",
              "status": "affected",
              "version": "6.4.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "6.3.23",
              "status": "affected",
              "version": "6.3.6",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A improper neutralization of special elements used in an sql command (\u0027sql injection\u0027) in Fortinet FortiWeb versions 6.3.17 through 7.6.1 allows attacker to gain information disclosure via crafted SQL queries"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 2.6,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:C",
            "version": "3.1"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "Information disclosure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-01-14T14:08:36.557Z",
        "orgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
        "shortName": "fortinet"
      },
      "references": [
        {
          "name": "https://fortiguard.fortinet.com/psirt/FG-IR-24-465",
          "url": "https://fortiguard.fortinet.com/psirt/FG-IR-24-465"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Please upgrade to FortiWeb version 7.6.2 or above"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
    "assignerShortName": "fortinet",
    "cveId": "CVE-2024-55593",
    "datePublished": "2025-01-14T14:08:36.557Z",
    "dateReserved": "2024-12-09T11:19:49.470Z",
    "dateUpdated": "2025-01-14T20:56:58.704Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-55593\",\"sourceIdentifier\":\"psirt@fortinet.com\",\"published\":\"2025-01-14T14:15:34.610\",\"lastModified\":\"2025-02-03T22:06:19.163\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A improper neutralization of special elements used in an sql command (\u0027sql injection\u0027) in Fortinet FortiWeb versions 6.3.17 through 7.6.1 allows attacker to gain information disclosure via crafted SQL queries\"},{\"lang\":\"es\",\"value\":\"Una neutralizaci\u00f3n incorrecta de elementos especiales utilizados en un comando SQL (\u0027inyecci\u00f3n SQL\u0027) en las versiones 6.3.17 a 7.6.1 de Fortinet FortiWeb permite a un atacante obtener informaci\u00f3n a trav\u00e9s de consultas SQL manipuladas.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@fortinet.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N\",\"baseScore\":2.7,\"baseSeverity\":\"LOW\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.2,\"impactScore\":1.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N\",\"baseScore\":2.7,\"baseSeverity\":\"LOW\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.2,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"psirt@fortinet.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-89\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:fortiweb:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.3.6\",\"versionEndExcluding\":\"7.6.2\",\"matchCriteriaId\":\"D1A4D0B4-27A6-4DD1-9E01-F0927EFC4ED4\"}]}]}],\"references\":[{\"url\":\"https://fortiguard.fortinet.com/psirt/FG-IR-24-465\",\"source\":\"psirt@fortinet.com\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-55593\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-01-14T15:15:29.839471Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-01-14T15:15:31.810Z\"}}], \"cna\": {\"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 2.6, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"LOW\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:C\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"LOW\"}}], \"affected\": [{\"cpes\": [], \"vendor\": \"Fortinet\", \"product\": \"FortiWeb\", \"versions\": [{\"status\": \"affected\", \"version\": \"7.6.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"7.6.1\"}, {\"status\": \"affected\", \"version\": \"7.4.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"7.4.6\"}, {\"status\": \"affected\", \"version\": \"7.2.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"7.2.10\"}, {\"status\": \"affected\", \"version\": \"7.0.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"7.0.10\"}, {\"status\": \"affected\", \"version\": \"6.4.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"6.4.3\"}, {\"status\": \"affected\", \"version\": \"6.3.6\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"6.3.23\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Please upgrade to FortiWeb version 7.6.2 or above\"}], \"references\": [{\"url\": \"https://fortiguard.fortinet.com/psirt/FG-IR-24-465\", \"name\": \"https://fortiguard.fortinet.com/psirt/FG-IR-24-465\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A improper neutralization of special elements used in an sql command (\u0027sql injection\u0027) in Fortinet FortiWeb versions 6.3.17 through 7.6.1 allows attacker to gain information disclosure via crafted SQL queries\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-89\", \"description\": \"Information disclosure\"}]}], \"providerMetadata\": {\"orgId\": \"6abe59d8-c742-4dff-8ce8-9b0ca1073da8\", \"shortName\": \"fortinet\", \"dateUpdated\": \"2025-01-14T14:08:36.557Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-55593\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-01-14T20:56:58.704Z\", \"dateReserved\": \"2024-12-09T11:19:49.470Z\", \"assignerOrgId\": \"6abe59d8-c742-4dff-8ce8-9b0ca1073da8\", \"datePublished\": \"2025-01-14T14:08:36.557Z\", \"assignerShortName\": \"fortinet\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.