An SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'RecalculateHDMWYC' message, which is split into 4 fields using the '~' character as the separator. An unauthenticated remote attacker can perform SQLi via the fourth field.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Delta Electronics | DIAEnergie |
Version: 0 < |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:deltaww:diaenergie:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "diaenergie", "vendor": "deltaww", "versions": [ { "lessThanOrEqual": "1.10.1.8610", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-4548", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-05-13T13:41:00.312856Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-20T20:06:39.622Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T20:47:40.056Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.tenable.com/security/research/tra-2024-13" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "DIAEnergie", "vendor": "Delta Electronics", "versions": [ { "lessThanOrEqual": "1.10.1.8610", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "An SQLi vulnerability exists in\u0026nbsp;Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a \u0027RecalculateHDMWYC\u0027 message, which is split into 4 fields using the \u0027~\u0027 character as the separator. An unauthenticated remote attacker can perform SQLi via the fourth field." } ], "value": "An SQLi vulnerability exists in\u00a0Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a \u0027RecalculateHDMWYC\u0027 message, which is split into 4 fields using the \u0027~\u0027 character as the separator. An unauthenticated remote attacker can perform SQLi via the fourth field." } ], "impacts": [ { "capecId": "CAPEC-66", "descriptions": [ { "lang": "en", "value": "CAPEC-66 SQL Injection" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20 Improper Input Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-06T13:51:07.049Z", "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be", "shortName": "tenable" }, "references": [ { "url": "https://www.tenable.com/security/research/tra-2024-13" } ], "source": { "discovery": "UNKNOWN" }, "title": "Delta Electronics DIAEnergie SQL Injection", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be", "assignerShortName": "tenable", "cveId": "CVE-2024-4548", "datePublished": "2024-05-06T13:51:07.049Z", "dateReserved": "2024-05-06T13:35:43.319Z", "dateUpdated": "2024-08-01T20:47:40.056Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-4548\",\"sourceIdentifier\":\"vulnreport@tenable.com\",\"published\":\"2024-05-06T14:15:08.533\",\"lastModified\":\"2024-11-21T09:43:04.937\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An SQLi vulnerability exists in\u00a0Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a \u0027RecalculateHDMWYC\u0027 message, which is split into 4 fields using the \u0027~\u0027 character as the separator. An unauthenticated remote attacker can perform SQLi via the fourth field.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad SQLi en Delta Electronics DIAEnergie v1.10.1.8610 y anteriores cuando CEBC.exe procesa un mensaje \u0027RecalculateHDMWYC\u0027, que se divide en 4 campos utilizando el car\u00e1cter \u0027~\u0027 como separador. Un atacante remoto no autenticado puede ejecutar SQLi a trav\u00e9s del cuarto campo.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"vulnreport@tenable.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"vulnreport@tenable.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]}],\"references\":[{\"url\":\"https://www.tenable.com/security/research/tra-2024-13\",\"source\":\"vulnreport@tenable.com\"},{\"url\":\"https://www.tenable.com/security/research/tra-2024-13\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.tenable.com/security/research/tra-2024-13\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-01T20:47:40.056Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-4548\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-05-13T13:41:00.312856Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:deltaww:diaenergie:-:*:*:*:*:*:*:*\"], \"vendor\": \"deltaww\", \"product\": \"diaenergie\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"1.10.1.8610\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-05-13T13:42:02.396Z\"}}], \"cna\": {\"title\": \"Delta Electronics DIAEnergie SQL Injection\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"impacts\": [{\"capecId\": \"CAPEC-66\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-66 SQL Injection\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Delta Electronics\", \"product\": \"DIAEnergie\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"1.10.1.8610\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.tenable.com/security/research/tra-2024-13\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"An SQLi vulnerability exists in\\u00a0Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a \u0027RecalculateHDMWYC\u0027 message, which is split into 4 fields using the \u0027~\u0027 character as the separator. An unauthenticated remote attacker can perform SQLi via the fourth field.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"An SQLi vulnerability exists in\u0026nbsp;Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a \u0027RecalculateHDMWYC\u0027 message, which is split into 4 fields using the \u0027~\u0027 character as the separator. An unauthenticated remote attacker can perform SQLi via the fourth field.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-20\", \"description\": \"CWE-20 Improper Input Validation\"}]}], \"providerMetadata\": {\"orgId\": \"5ac1ecc2-367a-4d16-a0b2-35d495ddd0be\", \"shortName\": \"tenable\", \"dateUpdated\": \"2024-05-06T13:51:07.049Z\"}}}", "cveMetadata": "{\"cveId\": \"CVE-2024-4548\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-01T20:47:40.056Z\", \"dateReserved\": \"2024-05-06T13:35:43.319Z\", \"assignerOrgId\": \"5ac1ecc2-367a-4d16-a0b2-35d495ddd0be\", \"datePublished\": \"2024-05-06T13:51:07.049Z\", \"assignerShortName\": \"tenable\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.