cve-2024-2992
Vulnerability from cvelistv5
Published
2024-03-27 19:00
Modified
2024-08-01 19:32
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS score ?
Summary
A vulnerability was found in Tenda FH1203 2.0.1.6 and classified as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258161 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1203/formSetCfm.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.258161 | Permissions Required, Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.258161 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.301371 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1203/formSetCfm.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.258161 | Permissions Required, Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.258161 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.301371 | Third Party Advisory, VDB Entry |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:fh1203_firmware:2.0.1.6:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1203_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "2.0.1.6" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2992", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-03-27T19:32:17.132085Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:30:29.972Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T19:32:42.476Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-258161 | Tenda FH1203 setcfm formSetCfm stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.258161" }, { "name": "VDB-258161 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.258161" }, { "name": "Submit #301371 | Tenda FH1203 V2.0.1.6 buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.301371" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1203/formSetCfm.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "FH1203", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "2.0.1.6" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_tu (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda FH1203 2.0.1.6 and classified as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258161 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Eine kritische Schwachstelle wurde in Tenda FH1203 2.0.1.6 gefunden. Es geht hierbei um die Funktion formSetCfm der Datei /goform/setcfm. Mit der Manipulation des Arguments funcpara1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-27T19:00:05.554Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-258161 | Tenda FH1203 setcfm formSetCfm stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.258161" }, { "name": "VDB-258161 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.258161" }, { "name": "Submit #301371 | Tenda FH1203 V2.0.1.6 buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.301371" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1203/formSetCfm.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-27T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-27T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-27T08:10:37.000Z", "value": "VulDB entry last update" } ], "title": "Tenda FH1203 setcfm formSetCfm stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2992", "datePublished": "2024-03-27T19:00:05.554Z", "dateReserved": "2024-03-27T07:04:44.807Z", "dateUpdated": "2024-08-01T19:32:42.476Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-2992\",\"sourceIdentifier\":\"cna@vuldb.com\",\"published\":\"2024-03-27T19:15:50.173\",\"lastModified\":\"2025-01-22T17:59:00.077\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability was found in Tenda FH1203 2.0.1.6 and classified as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258161 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad fue encontrada en Tenda FH1203 2.0.1.6 y clasificada como cr\u00edtica. Este problema afecta a la funci\u00f3n formSetCfm del archivo /goform/setcfm. La manipulaci\u00f3n del argumento funcpara1 provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque puede iniciarse de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. A esta vulnerabilidad se le asign\u00f3 el identificador VDB-258161. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:C/I:C/A:C\",\"baseScore\":9.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-121\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:tenda:fh1203_firmware:2.0.1.6:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E28AF51D-EBFB-4EC8-9FCB-C3DFAE1DBB2E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4E7A0DCB-AC18-4F32-86E2-F2C2E9118A71\"}]}]}],\"references\":[{\"url\":\"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1203/formSetCfm.md\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://vuldb.com/?ctiid.258161\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Permissions Required\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?id.258161\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?submit.301371\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1203/formSetCfm.md\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://vuldb.com/?ctiid.258161\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Permissions Required\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?id.258161\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?submit.301371\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://vuldb.com/?id.258161\", \"name\": \"VDB-258161 | Tenda FH1203 setcfm formSetCfm stack-based overflow\", \"tags\": [\"vdb-entry\", \"technical-description\", \"x_transferred\"]}, {\"url\": \"https://vuldb.com/?ctiid.258161\", \"name\": \"VDB-258161 | CTI Indicators (IOB, IOC, IOA)\", \"tags\": [\"signature\", \"permissions-required\", \"x_transferred\"]}, {\"url\": \"https://vuldb.com/?submit.301371\", \"name\": \"Submit #301371 | Tenda FH1203 V2.0.1.6 buffer overflow\", \"tags\": [\"third-party-advisory\", \"x_transferred\"]}, {\"url\": \"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1203/formSetCfm.md\", \"tags\": [\"exploit\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-01T19:32:42.476Z\"}}, {\"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-2992\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-03-27T19:32:17.132085Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:o:tenda:fh1203_firmware:2.0.1.6:*:*:*:*:*:*:*\"], \"vendor\": \"tenda\", \"product\": \"fh1203_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"2.0.1.6\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-04-24T20:52:20.468Z\"}, \"title\": \"CISA ADP Vulnrichment\"}], \"cna\": {\"title\": \"Tenda FH1203 setcfm formSetCfm stack-based overflow\", \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"wxhwxhwxh_tu (VulDB User)\"}], \"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\"}}, {\"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\"}}, {\"cvssV2_0\": {\"version\": \"2.0\", \"baseScore\": 9, \"vectorString\": \"AV:N/AC:L/Au:S/C:C/I:C/A:C\"}}], \"affected\": [{\"vendor\": \"Tenda\", \"product\": \"FH1203\", \"versions\": [{\"status\": \"affected\", \"version\": \"2.0.1.6\"}]}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2024-03-27T00:00:00.000Z\", \"value\": \"Advisory disclosed\"}, {\"lang\": \"en\", \"time\": \"2024-03-27T01:00:00.000Z\", \"value\": \"VulDB entry created\"}, {\"lang\": \"en\", \"time\": \"2024-03-27T08:10:37.000Z\", \"value\": \"VulDB entry last update\"}], \"references\": [{\"url\": \"https://vuldb.com/?id.258161\", \"name\": \"VDB-258161 | Tenda FH1203 setcfm formSetCfm stack-based overflow\", \"tags\": [\"vdb-entry\", \"technical-description\"]}, {\"url\": \"https://vuldb.com/?ctiid.258161\", \"name\": \"VDB-258161 | CTI Indicators (IOB, IOC, IOA)\", \"tags\": [\"signature\", \"permissions-required\"]}, {\"url\": \"https://vuldb.com/?submit.301371\", \"name\": \"Submit #301371 | Tenda FH1203 V2.0.1.6 buffer overflow\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1203/formSetCfm.md\", \"tags\": [\"exploit\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability was found in Tenda FH1203 2.0.1.6 and classified as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258161 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.\"}, {\"lang\": \"de\", \"value\": \"Eine kritische Schwachstelle wurde in Tenda FH1203 2.0.1.6 gefunden. Es geht hierbei um die Funktion formSetCfm der Datei /goform/setcfm. Mit der Manipulation des Arguments funcpara1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \\u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \\u00f6ffentlichen Verf\\u00fcgung.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-121\", \"description\": \"CWE-121 Stack-based Buffer Overflow\"}]}], \"providerMetadata\": {\"orgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"shortName\": \"VulDB\", \"dateUpdated\": \"2024-03-27T19:00:05.554Z\"}}}", "cveMetadata": "{\"cveId\": \"CVE-2024-2992\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-01T19:32:42.476Z\", \"dateReserved\": \"2024-03-27T07:04:44.807Z\", \"assignerOrgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"datePublished\": \"2024-03-27T19:00:05.554Z\", \"assignerShortName\": \"VulDB\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.